Literature DB >> 30349957

SPECMAR: fast heart rate estimation from PPG signal using a modified spectral subtraction scheme with composite motion artifacts reference generation.

Mohammad Tariqul Islam1, Sk Tanvir Ahmed1, Celia Shahnaz1, Shaikh Anowarul Fattah2.   

Abstract

The task of heart rate estimation using photoplethysmographic (PPG) signal is challenging due to the presence of various motion artifacts in the recorded signals. In this paper, a fast algorithm for heart rate estimation based on modified SPEctral subtraction scheme utilizing Composite Motion Artifacts Reference generation (SPECMAR) is proposed using two-channel PPG and three-axis accelerometer signals. First, the preliminary noise reduction is obtained by filtering unwanted frequency components from the recorded signals. Next, a composite motion artifacts reference generation method is developed to be employed in the proposed SPECMAR algorithm for motion artifacts reduction. The heart rate is then computed from the noise and motion artifacts reduced PPG signal. Finally, a heart rate tracking algorithm is proposed considering neighboring estimates. The performance of the SPECMAR algorithm has been tested on publicly available PPG database. The average heart rate estimation error is found to be 2.09 BPM on 23 recordings. The Pearson correlation is 0.9907. Due to low computational complexity, the method is faster than the comparing methods. The low estimation error, smooth and fast heart rate tracking makes SPECMAR an ideal choice to be implemented in wearable devices. Graphical Abstract Flow chart for the heart rate estimation using modified SPEctral subtraction scheme utilizing Composite Motion Artifacts Reference generation (SPECMAR) from photoplethysmographic (PPG) signals.

Entities:  

Keywords:  Heart rate estimation; Motion artifacts removal; Photoplethysmograph; Spectral subtraction

Mesh:

Year:  2018        PMID: 30349957     DOI: 10.1007/s11517-018-1909-x

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  12 in total

1.  Estimation of heart rate from photoplethysmography during physical exercise using Wiener filtering and the phase vocoder.

Authors:  Andriy Temko
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2015-08

Review 2.  Photoplethysmography and its application in clinical physiological measurement.

Authors:  John Allen
Journal:  Physiol Meas       Date:  2007-02-20       Impact factor: 2.833

3.  Adaptive blood pressure estimation from wearable PPG sensors using peripheral artery pulse wave velocity measurements and multi-channel blind identification of local arterial dynamics.

Authors:  Devin B McCombie; Andrew T Reisner; H Harry Asada
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2006

4.  Motion artifact reduction in photoplethysmography using independent component analysis.

Authors:  Byung S Kim; Sun K Yoo
Journal:  IEEE Trans Biomed Eng       Date:  2006-03       Impact factor: 4.538

5.  Photoplethysmography-Based Heart Rate Monitoring in Physical Activities via Joint Sparse Spectrum Reconstruction.

Authors:  Zhilin Zhang
Journal:  IEEE Trans Biomed Eng       Date:  2015-08       Impact factor: 4.538

6.  Heart monitoring systems--a review.

Authors:  Puneet Kumar Jain; Anil Kumar Tiwari
Journal:  Comput Biol Med       Date:  2014-08-23       Impact factor: 4.589

7.  TROIKA: a general framework for heart rate monitoring using wrist-type photoplethysmographic signals during intensive physical exercise.

Authors:  Zhilin Zhang; Zhouyue Pi; Benyuan Liu
Journal:  IEEE Trans Biomed Eng       Date:  2014-09-19       Impact factor: 4.538

Review 8.  A review of methods for the signal quality assessment to improve reliability of heart rate and blood pressures derived parameters.

Authors:  Nicolò Gambarotta; Federico Aletti; Giuseppe Baselli; Manuela Ferrario
Journal:  Med Biol Eng Comput       Date:  2016-02-23       Impact factor: 2.602

9.  A motion-tolerant adaptive algorithm for wearable photoplethysmographic biosensors.

Authors:  Rasoul Yousefi; Mehrdad Nourani; Sarah Ostadabbas; Issa Panahi
Journal:  IEEE J Biomed Health Inform       Date:  2014-03       Impact factor: 5.772

10.  Investigation of oesophageal photoplethysmographic signals and blood oxygen saturation measurements in cardiothoracic surgery patients.

Authors:  P A Kyriacou; S Powell; R M Langford; D P Jones
Journal:  Physiol Meas       Date:  2002-08       Impact factor: 2.833

View more
  2 in total

1.  SPARE: A Spectral Peak Recovery Algorithm for PPG Signals Pulsewave Reconstruction in Multimodal Wearable Devices.

Authors:  Giulio Masinelli; Fabio Dell'Agnola; Adriana Arza Valdés; David Atienza
Journal:  Sensors (Basel)       Date:  2021-04-13       Impact factor: 3.576

2.  Novel wearable and contactless monitoring devices to identify deteriorating patients in the clinical setting: a systematic review protocol.

Authors:  Peter Y Chan; John McNeil; Tam Nguyen; Nicholas Ryan; Ingrid Hopper
Journal:  Syst Rev       Date:  2020-05-06
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.