Pulse transit time based on piezoelectric technique at the radial artery.

Jong Yong Abdiel Foo1, Chu Sing Lim.   

Abstract

OBJECTIVES: Pulse transit time (PTT) has shown its potential in relevant cardiovascular and cardiorespiratory studies. However, the use of photoplethysmography (PPG) in PTT measurement can be limited in events of poor peripheral perfusion. Uninterrupted PTT monitoring may also not be achievable when less cooperative patients distribute the PPG probe due to its prominent light source. Hence, there is a need for an alternative method to measure PTT in such incidents.
METHODS: In this study, the piezoelectric (PIEZO) technique to detect pulsations from a human wrist above the radial artery to estimate PTT is presented. 17 healthy adults (11 male; age range of 21-33 years) were recruited to compare PTT and heart rate (HR) differences between the PPG and PIEZO methods. These time-related derivations were made with respect to an electrocardiogram (ECG).
RESULTS: The timing consistency of the PIEZO transducer shows significant correlations (p < 0.01) to those derived from the ECG and a pulse oximeter. Particularly, there is a high level of agreement of < 1 beat per minute (bpm) difference in HR estimates observed when compared to the two commercial devices in the respective Bland-Altman plots. Comparison of PTT obtained from the PIEZO transducer against the PPG signal shows constantly lower values due to the shorter path length it requires to propagate. A regression equation was formulated to relate the PTT values acquired from both these signals.
CONCLUSIONS: Preliminary findings herein suggest that the PIEZO technique can be useful as an alternative for PTT monitoring. This shows promise to be more accommodating for less cooperative patients or those with insufficient peripheral perfusion.

Entities:  

Mesh:

Year:  2006        PMID: 16703422     DOI: 10.1007/s10877-006-9019-y

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  16 in total

1.  Age-related changes in peripheral pulse timing characteristics at the ears, fingers and toes.

Authors:  J Allen; A Murray
Journal:  J Hum Hypertens       Date:  2002-10       Impact factor: 3.012

2.  Elastic, dielectric, and piezoelectric losses in piezoceramics: how it works all together.

Authors:  Alex V Mezheritsky
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2004-06       Impact factor: 2.725

Review 3.  Guidelines for the cold pressor task as an experimental pain stimulus for use with children.

Authors:  Carl L von Baeyer; Tiina Piira; Christine T Chambers; Manuela Trapanotto; Lonnie K Zeltzer
Journal:  J Pain       Date:  2005-04       Impact factor: 5.820

4.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

5.  Effects of aging on changing arterial compliance and left ventricular load in a northern Chinese urban community.

Authors:  A P Avolio; S G Chen; R P Wang; C L Zhang; M F Li; M F O'Rourke
Journal:  Circulation       Date:  1983-07       Impact factor: 29.690

6.  Determining the artifact sensitivity of recent pulse oximeters during laboratory benchmarking.

Authors:  S W Kästle; E Konecny
Journal:  J Clin Monit Comput       Date:  2000       Impact factor: 2.502

7.  Pulse transit time as a measure of arousal and respiratory effort in children with sleep-disordered breathing.

Authors:  Eliot S Katz; Janita Lutz; Cheryl Black; Carole L Marcus
Journal:  Pediatr Res       Date:  2003-02-05       Impact factor: 3.756

8.  Arterial distensibility in children and teenagers: normal evolution and the effect of childhood vasculitis.

Authors:  Y F Cheung; P A Brogan; C B Pilla; M J Dillon; A N Redington
Journal:  Arch Dis Child       Date:  2002-10       Impact factor: 3.791

9.  Effects of passive smoking on blood pressure and aortic pressure waveform in healthy young adults--influence of gender.

Authors:  Azra Mahmud; John Feely
Journal:  Br J Clin Pharmacol       Date:  2004-01       Impact factor: 4.335

10.  Investigation of oesophageal photoplethysmographic signals and blood oxygen saturation measurements in cardiothoracic surgery patients.

Authors:  P A Kyriacou; S Powell; R M Langford; D P Jones
Journal:  Physiol Meas       Date:  2002-08       Impact factor: 2.833

View more
  2 in total

1.  Cuffless Blood Pressure Estimation Using Pressure Pulse Wave Signals.

Authors:  Zeng-Ding Liu; Ji-Kui Liu; Bo Wen; Qing-Yun He; Ye Li; Fen Miao
Journal:  Sensors (Basel)       Date:  2018-12-02       Impact factor: 3.576

2.  An Arterial Compliance Sensor for Cuffless Blood Pressure Estimation Based on Piezoelectric and Optical Signals.

Authors:  Cheng-Yan Guo; Hao-Ching Chang; Kuan-Jen Wang; Tung-Li Hsieh
Journal:  Micromachines (Basel)       Date:  2022-08-16       Impact factor: 3.523

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.