Literature DB >> 23475176

The analysis of transesophageal oxygen saturation photoplethysmography from different signal sources.

Ling Mou1, Quan Gong, Wei Wei, Bo Gao.   

Abstract

The photoplethysmography (PPG) signals detected by transesophageal oximetry sensor toward aorta arch (AA), descending aorta (DA), and left ventricle (LV) under the guidance of transesophageal echocardiography (TEE) were investigated, and the effects of filter application on PPG signals were evaluated. Eleven cardiac surgical patients were involved. After anesthesia was induced, the TEE probe with a modified pulse oximetry sensor was inserted. Under the guidance of TEE, the AA PPG, DA PPG and LV PPG were detected respectively when ventilator was on and off. The mean alternating current (AC) amplitudes and direct current (DC) values of original and filtered PPG signals were measured. The ratio of AC and DC value (AC/DC) and ventilation-induced AC variations were calculated. Satisfactory PPG waveforms were obtained in all patients under the guidance of TEE. The AC amplitude in LV PPG was significant larger than in AA and DA PPG, and both AC/DC and ventilation-induced AC variation in LV PPG were significantly higher than in AA PPG or DA PPG either. There were no significant differences of AC amplitude between filtered and ventilation off PPG signals. The AC amplitudes and AC/DC toward LV are significantly higher than transesophageal oximeter toward AA or DA, and the effect of mechanical ventilation on transesophageal PPG can be obviously reduced by filtering techniques.

Entities:  

Mesh:

Year:  2013        PMID: 23475176     DOI: 10.1007/s10877-013-9450-9

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  18 in total

1.  Pulse oximetry plethysmographic waveform during changes in blood volume.

Authors:  M Shamir; L A Eidelman; Y Floman; L Kaplan; R Pizov
Journal:  Br J Anaesth       Date:  1999-02       Impact factor: 9.166

2.  A pilot study of pharyngeal pulse oximetry with the laryngeal mask airway: a comparison with finger oximetry and arterial saturation measurements in healthy anesthetized patients.

Authors:  C Keller; J Brimacombe; F Agrò; J Margreiter
Journal:  Anesth Analg       Date:  2000-02       Impact factor: 5.108

3.  The feasibility of transesophageal echocardiograph-guided right and left ventricular oximetry in hemodynamically stable patients undergoing coronary artery bypass grafting.

Authors:  J Margreiter; C Keller; J Brimacombe
Journal:  Anesth Analg       Date:  2002-04       Impact factor: 5.108

4.  A pilot study of left tracheal pulse oximetry.

Authors:  J Brimacombe; C Keller; J Margreiter
Journal:  Anesth Analg       Date:  2000-10       Impact factor: 5.108

Review 5.  Noninvasive monitoring of peripheral perfusion.

Authors:  Alexandre Lima; Jan Bakker
Journal:  Intensive Care Med       Date:  2005-09-17       Impact factor: 17.440

6.  Effect of peripheral vasoconstriction on pulse oximetry.

Authors:  Pekka Talke; Claudia Stapelfeldt
Journal:  J Clin Monit Comput       Date:  2006-07-14       Impact factor: 2.502

7.  Variations in arterial blood pressure and photoplethysmography during mechanical ventilation.

Authors:  Giuseppe Natalini; Antonio Rosano; Maria E Franceschetti; Paola Facchetti; Achille Bernardini
Journal:  Anesth Analg       Date:  2006-11       Impact factor: 5.108

8.  Calibrated photoplethysmographic estimation of digital pulse volume and arterial compliance.

Authors:  Rein Raamat; Kersti Jagomägi; Jaak Talts
Journal:  Clin Physiol Funct Imaging       Date:  2007-11       Impact factor: 2.273

9.  Accuracy and utility of a new reflectance pulse oximeter for fetal monitoring during labor.

Authors:  A Izumi; H Minakami; I Sato
Journal:  J Clin Monit       Date:  1997-03

10.  Investigation of oesophageal photoplethysmographic signals and blood oxygen saturation measurements in cardiothoracic surgery patients.

Authors:  P A Kyriacou; S Powell; R M Langford; D P Jones
Journal:  Physiol Meas       Date:  2002-08       Impact factor: 2.833

View more
  2 in total

1.  Can the descending aortic stroke volume be estimated by transesophageal descending aortic photoplethysmography?

Authors:  Peng Ling; Gong Quan; Yu Siyuan; Gao Bo; Wei Wei
Journal:  J Anesth       Date:  2017-03-27       Impact factor: 2.078

2.  Assessment of postoperative pain intensity by using photoplethysmography.

Authors:  Peng Ling; Yu Siyuan; Wei Wei; Gong Quan; Gao Bo
Journal:  J Anesth       Date:  2014-05-15       Impact factor: 2.078

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.