Evaluation of Kodak EDR2 film for dose verification of intensity modulated radiation therapy delivered by a static multileaf collimator.

X R Zhu1, P A Jursinic, D F Grimm, F Lopez, J J Rownd, M T Gillin.   

Abstract

A new type of radiographic film, Kodak EDR2 film, was evaluated for dose verification of intensity modulated radiation therapy (IMRT) delivered by a static multileaf collimator (SMLC). A sensitometric curve of EDR2 film irradiated by a 6 MV x-ray beam was compared with that of Kodak X-OMAT V (XV) film. The effects of field size, depth and dose rate on the sensitometric curve were also studied. It is found that EDR2 film is much less sensitive than XV film. In high-energy x-ray beams, the double hit process is the dominant mechanism that renders the grains on EDR2 films developable. As a result, in the dose range that is commonly used for film dosimetry for IMRT and conventional external beam therapy, the sensitometric curves of EDR2 films cannot be approximated as a linear function, OD = c * D. Within experimental uncertainty, the film sensitivity does not depend on the dose rate (50 vs 300 MU/min) or dose per pulse (from 1.0 x 10(-4) to 4.21 x 10(-4) Gy/pulse). Field sizes and depths (up to field size of 10 x 10 cm2 and depth = 10 cm) have little effect on the sensitometric curves. Percent depth doses (PDDs) for both 6 and 23 MV x rays were measured with both EDR2 and XV films and compared with ion chamber data. Film data are within 2.5% of the ion chamber results. Dose profiles measured with EDR2 film are consistent with those measured with an ion chamber. Examples of measured IMRT isodose distributions versus calculated isodoses are presented. We have used EDR2 films for verification of all IMRT patients treated by SMLC in our clinic. In most cases, with EDR2 film, actual clinical daily fraction doses can be used for verification of composite isodose distributions of SMLC-based IMRT.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12201414     DOI: 10.1118/1.1493781

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  29 in total

1.  Dose verification of IMRT by use of a COMPASS transmission detector.

Authors:  Yuji Nakaguchi; Fujio Araki; Masato Maruyama; Shunji Saiga
Journal:  Radiol Phys Technol       Date:  2011-10-26

2.  Clinical implementation of volumetric intensity-modulated arc therapy (VMAT) with ERGO++.

Authors:  Dirk Wolff; Florian Stieler; Brigitte Hermann; Katharina Heim; Sven Clausen; Jens Fleckenstein; Martin Polednik; Volker Steil; Frederik Wenz; Frank Lohr
Journal:  Strahlenther Onkol       Date:  2010-04-26       Impact factor: 3.621

3.  Quasi-IMAT study with conventional equipment to show high plan quality with a single gantry arc.

Authors:  Judith Alvarez Moret; Oliver Kölbl; Ludwig Bogner
Journal:  Strahlenther Onkol       Date:  2009-02-18       Impact factor: 3.621

4.  Overestimation of low-dose radiation in intensity-modulated radiotherapy with sliding-window technique.

Authors:  Hilke Vorwerk; Daniela Wagner; Björn Seitz; Hans Christiansen; Hendrik A Wolff; Clemens F Hess
Journal:  Strahlenther Onkol       Date:  2009-12       Impact factor: 3.621

5.  Simulation for improvement of system sensitivity of radiochromic film dosimetry with different band-pass filters and scanner light intensities.

Authors:  Takeshi Kamomae; Yuki Miyabe; Akira Sawada; Osamu Matoba; Manabu Nakata; Shinsuke Yano; Toru Takakura; Takashi Mizowaki; Akio Itoh; Masahiro Hiraoka
Journal:  Radiol Phys Technol       Date:  2011-03-17

6.  Validation of a quick three-dimensional dose verification system for pre-treatment IMRT QA.

Authors:  Yuji Nakaguchi; Fujio Araki; Takeshi Ono; Yuki Tomiyama; Masato Maruyama; Nozomu Nagasue; Yoshinobu Shimohigashi; Yudai Kai
Journal:  Radiol Phys Technol       Date:  2014-09-27

7.  Optimal sensitometric curves of Kodak EDR2 film for dynamic intensity modulated radiation therapy verification.

Authors:  S Suriyapee; N Pitaxtarnin; S Oonsiri; C Jumpangern; I Israngkul Na Ayuthaya
Journal:  Biomed Imaging Interv J       Date:  2008-01-01

8.  Quantitative megavoltage radiation therapy dosimetry using the storage phosphor KCl: Eu2+.

Authors:  Zhaohui Han; Joseph P Driewer; Yuanshui Zheng; Daniel A Low; H Harold Li
Journal:  Med Phys       Date:  2009-08       Impact factor: 4.071

9.  Absolute dose verification of static intensity modulated radiation therapy (IMRT) with ion chambers of various volumes and TLD detectors.

Authors:  Hediye Acun-Bucht; Ebru Tuncay; Emin Darendeliler; Gönül Kemikler
Journal:  Rep Pract Oncol Radiother       Date:  2018-05-19

10.  Calculation of excess dose to the eye phantom due to a distanced shielding for electron therapy in head and neck cancers.

Authors:  Keyvan Jabbari; Mahnaz Roayaei; Hosein Saberi
Journal:  J Med Signals Sens       Date:  2012-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.