Overestimation of low-dose radiation in intensity-modulated radiotherapy with sliding-window technique.

Hilke Vorwerk1, Daniela Wagner, Björn Seitz, Hans Christiansen, Hendrik A Wolff, Clemens F Hess.   

Abstract

PURPOSE: To analyze different control-system limitations on the measured dose distributions in low-dose regions of simplified intensity fields with an electronic portal imaging device to ascertain the optimal settings for the control-system limitations in the planning system.
MATERIAL AND METHODS: The authors created one field with an "optimal fluence" of intensity 1.0 (full dose) and one field with intensity 0.0 (no dose) in the central part of the field. The influence of different dose rates (DRs) and maximum leaf speeds (LS) on the calculated and measured dose and dose profiles were analyzed.
RESULTS: Good agreement between calculated and measured dose in the case of a field of intensity 1.0 was found. For the field with intensity 0.0, the measured dose was 20-60% lower than the dose calculated by the "actual fluence". The results were found dependent on the DR and LS.
CONCLUSION: The overestimation in regions of optimal intensity 0.0 by the planning system cannot be resolved by the user. Taking the measured dose in the region of desired intensity 1.0 and other technical limitations (like beam hold interrupts or spikes in the cross and longitudinal profiles) into consideration, the application of an LS of 2.5 cm/s and a DR of 500 MU/min is recommended in order to minimize radiation dose applied to organs at risk, which are located in regions of low intensity, like, for example, the spinal cord.

Mesh:

Year:  2009        PMID: 20013092     DOI: 10.1007/s00066-009-2028-2

Source DB:  PubMed          Journal:  Strahlenther Onkol        ISSN: 0179-7158            Impact factor:   3.621


  22 in total

1.  Dosimetric verification of intensity modulated beams produced with dynamic multileaf collimation using an electronic portal imaging device.

Authors:  K L Pasma; M L Dirkx; M Kroonwijk; A G Visser; B J Heijmen
Journal:  Med Phys       Date:  1999-11       Impact factor: 4.071

2.  Characterization of a commercial multileaf collimator used for intensity modulated radiation therapy.

Authors:  D A Low; J W Sohn; E E Klein; J Markman; S Mutic; J F Dempsey
Journal:  Med Phys       Date:  2001-05       Impact factor: 4.071

3.  A 2-D diode array and analysis software for verification of intensity modulated radiation therapy delivery.

Authors:  Paul A Jursinic; Ben E Nelms
Journal:  Med Phys       Date:  2003-05       Impact factor: 4.071

4.  Dosimetric IMRT verification with a flat-panel EPID.

Authors:  B Warkentin; S Steciw; S Rathee; B G Fallone
Journal:  Med Phys       Date:  2003-12       Impact factor: 4.071

5.  Dosimetric performance of an enhanced dose range radiographic film for intensity-modulated radiation therapy quality assurance.

Authors:  Arthur J Olch
Journal:  Med Phys       Date:  2002-09       Impact factor: 4.071

Review 6.  Intensity-modulated radiotherapy for head and neck cancer.

Authors:  Hale B Caglar; Aaron M Allen
Journal:  Clin Adv Hematol Oncol       Date:  2007-06

7.  Postoperative radiotherapy for prostate cancer : evaluation of target motion and treatment techniques (intensity-modulated versus conformal radiotherapy).

Authors:  Michael Pinkawa; Jaroslav Siluschek; Bernd Gagel; Marc D Piroth; Cengiz Demirel; Branka Asadpour; Michael J Eble
Journal:  Strahlenther Onkol       Date:  2007-01       Impact factor: 3.621

8.  Comparison of fixed-beam IMRT, helical tomotherapy, and IMPT for selected cases.

Authors:  Jan Muzik; Martin Soukup; Markus Alber
Journal:  Med Phys       Date:  2008-04       Impact factor: 4.071

9.  Leaf transmission reduction using moving jaws for dynamic MLC IMRT.

Authors:  D Schmidhalter; M K Fix; P Niederer; R Mini; P Manser
Journal:  Med Phys       Date:  2007-09       Impact factor: 4.071

10.  Experimental investigation of the response of an amorphous silicon EPID to intensity modulated radiotherapy beams.

Authors:  Peter B Greer; Philip Vial; Lyn Oliver; Clive Baldock
Journal:  Med Phys       Date:  2007-11       Impact factor: 4.071

View more
  3 in total

1.  Simple proposal for dosimetry with an Elekta iViewGT™ electronic portal imaging device (EPID) using commercial software modules.

Authors:  Janett Liebich; Jörg Licher; Christian Scherf; Eugen Kara; Nadine Koch; Claus Rödel; Ulla Ramm
Journal:  Strahlenther Onkol       Date:  2011-04-26       Impact factor: 3.621

2.  Helical tomotherapy in cervical cancer patients: simultaneous integrated boost concept: technique and acute toxicity.

Authors:  Simone Marnitz; Carmen Stromberger; Michael Kawgan-Kagan; Waldemar Wlodarczyk; Ulrich Jahn; Achim Schneider; Uwe Ulrich; Volker Budach; Christhardt Köhler
Journal:  Strahlenther Onkol       Date:  2010-09-30       Impact factor: 3.621

3.  A planning comparison of dynamic IMRT for different collimator leaf thicknesses with helical tomotherapy and RapidArc for prostate and head and neck tumors.

Authors:  Vesna Jacob; Wolfgang Bayer; Sabrina T Astner; R Busch; Peter Kneschaurek
Journal:  Strahlenther Onkol       Date:  2010-08-30       Impact factor: 3.621

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.