Literature DB >> 3210952

Fast SSFP gradient echo sequence for simultaneous acquisitions of FID and echo signals.

S Y Lee1, Z H Cho.   

Abstract

Recently, the gradient echo imaging sequence in conjunction with small flip angle excitations and short repetition times has been widely used for fast NMR imaging. As the repetition time decreases to an extent comparable to the spin-spin relaxation time T2, the residual phase coherency of the transverse spin magnetization tends to form another nuclear signal which is heavily weighted by T2 and similar to a long TR/long TE spin-echo signal. This effect, although expected, has not been utilized in the conventional fast gradient echo imaging. When this residual phase coherency is utilized in conjunction with the fast SSFP (steady-state free precession) technique, both the FID and the echo signals can be obtained. In this paper, we have proposed a new technique by which simultaneous acquisitions of both the FID and the echo signals are possible. Experiments on this fast SSFP mode imaging have shown that the FID signal is T1-weighted while the echo signal is strongly T2-weighted. The flip angle optimal for maximizing signal and related contrast are also studied in conjunction with the proposed sequence and the experimental results are presented.

Mesh:

Year:  1988        PMID: 3210952     DOI: 10.1002/mrm.1910080204

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  12 in total

1.  Multishot EPI-SSFP in the heart.

Authors:  Daniel A Herzka; Peter Kellman; Anthony H Aletras; Michael A Guttman; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2002-04       Impact factor: 4.668

Review 2.  Rapid gradient-echo imaging.

Authors:  Brian A Hargreaves
Journal:  J Magn Reson Imaging       Date:  2012-10-23       Impact factor: 4.813

3.  Imaging and T2 relaxometry of short-T2 connective tissues in the knee using ultrashort echo-time double-echo steady-state (UTEDESS).

Authors:  Akshay S Chaudhari; Bragi Sveinsson; Catherine J Moran; Emily J McWalter; Ethan M Johnson; Tao Zhang; Garry E Gold; Brian A Hargreaves
Journal:  Magn Reson Med       Date:  2017-01-11       Impact factor: 4.668

4.  Combined 5-minute double-echo in steady-state with separated echoes and 2-minute proton-density-weighted 2D FSE sequence for comprehensive whole-joint knee MRI assessment.

Authors:  Akshay S Chaudhari; Kathryn J Stevens; Bragi Sveinsson; Jeff P Wood; Christopher F Beaulieu; Edwin H G Oei; Jarrett K Rosenberg; Feliks Kogan; Marcus T Alley; Garry E Gold; Brian A Hargreaves
Journal:  J Magn Reson Imaging       Date:  2018-12-23       Impact factor: 4.813

5.  A simple analytic method for estimating T2 in the knee from DESS.

Authors:  B Sveinsson; A S Chaudhari; G E Gold; B A Hargreaves
Journal:  Magn Reson Imaging       Date:  2016-12-23       Impact factor: 2.546

6.  Five-minute knee MRI for simultaneous morphometry and T2 relaxometry of cartilage and meniscus and for semiquantitative radiological assessment using double-echo in steady-state at 3T.

Authors:  Akshay S Chaudhari; Marianne S Black; Susanne Eijgenraam; Wolfgang Wirth; Susanne Maschek; Bragi Sveinsson; Felix Eckstein; Edwin H G Oei; Garry E Gold; Brian A Hargreaves
Journal:  J Magn Reson Imaging       Date:  2017-11-01       Impact factor: 4.813

7.  SNR-weighted regularization of ADC estimates from double-echo in steady-state (DESS).

Authors:  Bragi Sveinsson; Garry E Gold; Brian A Hargreaves; Daehyun Yoon
Journal:  Magn Reson Med       Date:  2018-08-19       Impact factor: 4.668

8.  High-resolution, three-dimensional diffusion-weighted breast imaging using DESS.

Authors:  Kristin L Granlund; Ernesto Staroswiecki; Marcus T Alley; Bruce L Daniel; Brian A Hargreaves
Journal:  Magn Reson Imaging       Date:  2014-01-03       Impact factor: 2.546

9.  Utilizing shared information between gradient-spoiled and RF-spoiled steady-state MRI signals.

Authors:  Bragi Sveinsson; Garry E Gold; Brian A Hargreaves; Daehyun Yoon
Journal:  Phys Med Biol       Date:  2021-01-14       Impact factor: 3.609

Review 10.  Rapid Knee MRI Acquisition and Analysis Techniques for Imaging Osteoarthritis.

Authors:  Akshay S Chaudhari; Feliks Kogan; Valentina Pedoia; Sharmila Majumdar; Garry E Gold; Brian A Hargreaves
Journal:  J Magn Reson Imaging       Date:  2019-11-21       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.