Literature DB >> 1627863

Analysis of flow effects in echo-planar imaging.

K Butts1, S J Riederer.   

Abstract

The effects on the phase of spins moving during echo-planar imaging (EPI) acquisition were studied. Standard single-shot and interleaved multishot blipped EPI acquisitions were considered, assuming either high gradient strength and slew rates or standard gradient strength and slew rates. A spiral k-space trajectory was also considered. Flow components in the section-select and phase- and frequency-encoding directions were analyzed separately. While the effect of flow in the section-select direction is identical to that in a standard two-dimensional Fourier transform (2DFT) acquisition, flow in the phase- or frequency-encoding directions can have substantial effects on the image, different from that in 2DFT imaging. The magnitude of these effects, which include displacement, distortion, and/or ghosting of vascular structures, is analyzed and predicted for a given velocity and direction of flow, the specific acquisition sequence, and the strength and slew rate of the gradients. For example, 50-cm/sec flow along the phase-encoding direction can cause a blurring of 1.25 cm full width at half maximum for blipped EPI with high-strength gradients, assuming a 40-cm field of view and 64 x 64 matrix.

Mesh:

Year:  1992        PMID: 1627863     DOI: 10.1002/jmri.1880020306

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  7 in total

1.  High temporal resolution phase contrast MRI with multiecho acquisitions.

Authors:  Richard B Thompson; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2002-03       Impact factor: 4.668

2.  Multishot EPI-SSFP in the heart.

Authors:  Daniel A Herzka; Peter Kellman; Anthony H Aletras; Michael A Guttman; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2002-04       Impact factor: 4.668

Review 3.  Advances in vascular echoplanar imaging.

Authors:  J F Debatin; D A Leung; S Wildermuth; D Holtz; G C McKinnon
Journal:  Cardiovasc Intervent Radiol       Date:  1995 Sep-Oct       Impact factor: 2.740

4.  Flow compensated quantitative susceptibility mapping for venous oxygenation imaging.

Authors:  Bo Xu; Tian Liu; Pascal Spincemaille; Martin Prince; Yi Wang
Journal:  Magn Reson Med       Date:  2013-09-04       Impact factor: 4.668

5.  Fast measurement of blood T1 in the human jugular vein at 3 Tesla.

Authors:  Qin Qin; John J Strouse; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2010-11-30       Impact factor: 4.668

6.  Whole-Heart 4D Flow MRI for Evaluation of Normal and Regurgitant Valvular Flow: A Quantitative Comparison Between Pseudo-Spiral Sampling and EPI Readout.

Authors:  Carmen P S Blanken; Lukas M Gottwald; Jos J M Westenberg; Eva S Peper; Bram F Coolen; Gustav J Strijkers; Aart J Nederveen; R Nils Planken; Pim van Ooij
Journal:  J Magn Reson Imaging       Date:  2021-09-12       Impact factor: 5.119

7.  Echo planar imaging-induced errors in intracardiac 4D flow MRI quantification.

Authors:  Jos J M Westenberg; Hans C van Assen; Pieter J van den Boogaard; Jelle J Goeman; Hicham Saaid; Jason Voorneveld; Johan Bosch; Sasa Kenjeres; Tom Claessens; Pankaj Garg; Marc Kouwenhoven; Hildo J Lamb
Journal:  Magn Reson Med       Date:  2021-12-05       Impact factor: 3.737

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.