Literature DB >> 3185135

The application of steady-state free precession in rapid 2DFT NMR imaging: FAST and CE-FAST sequences.

M L Gyngell1.   

Abstract

In the classic spectroscopic steady-state free precession (SSFP) experiment, a regular sequence of phase-coherent radio frequency pulses is applied with constant flip angle and a repetition time shorter than the NMR relaxation times of the sample. As the steady state is reached, an NMR signal appears between pulses that consists of two distinct components: a free induction signal following the RF pulses and decaying during the repetition interval and a spin-echo-like signal forming at its end prior to the subsequent RF pulse. Both signals may be exploited for NMR imaging if the gradient schemes fulfill the phase coherence requirements of SSFP. This article describes two Fourier acquired steady-state sequences dubbed FAST and CE-FAST, which may be used for the rapid acquisition of NMR images from the SSFP signals.

Mesh:

Year:  1988        PMID: 3185135     DOI: 10.1016/0730-725x(88)90478-x

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  20 in total

1.  Multishot EPI-SSFP in the heart.

Authors:  Daniel A Herzka; Peter Kellman; Anthony H Aletras; Michael A Guttman; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2002-04       Impact factor: 4.668

2.  Comparison between tagged MRI and standard cine MRI for evaluation of left ventricular ejection fraction.

Authors:  Christophe Dornier; G Aernout Somsen; Marko K Ivancevic; Nael F Osman; Dominique Didier; Alberto Righetti; Jean-Paul Vallée
Journal:  Eur Radiol       Date:  2004-04-06       Impact factor: 5.315

3.  Fast 1H spectroscopic imaging using steady state free precession and spectral-spatial RF pulses.

Authors:  Christian Geppert; Wolfgang Dreher; Matthias Althaus; Dieter Leibfritz
Journal:  MAGMA       Date:  2006-09-08       Impact factor: 2.310

4.  Magnetic resonance imaging (MRI) detection of the murine brain response to light: temporal differentiation and negative functional MRI changes.

Authors:  W Huang; I Plyka; H Li; E M Eisenstein; N D Volkow; C S Springer
Journal:  Proc Natl Acad Sci U S A       Date:  1996-06-11       Impact factor: 11.205

5.  Echo-dephased steady state free precession.

Authors:  Sunil Patil; Oliver Bieri; Klaus Scheffler
Journal:  MAGMA       Date:  2009-05-16       Impact factor: 2.310

6.  Music-based magnetic resonance fingerprinting to improve patient comfort during MRI examinations.

Authors:  Dan Ma; Eric Y Pierre; Yun Jiang; Mark D Schluchter; Kawin Setsompop; Vikas Gulani; Mark A Griswold
Journal:  Magn Reson Med       Date:  2015-07-16       Impact factor: 4.668

7.  Contrast-modified gradient echo imaging using rotary echo preparatory pulses.

Authors:  X P Zhu; P B Chilvers; C E Hutchinson; G A Morris; J M Hawnaur; J E Adams; C J Taylor
Journal:  MAGMA       Date:  1997-09       Impact factor: 2.310

8.  Three-dimensional MR myelography of the lumbar spine: comparative case study to X-ray myelography.

Authors:  K E Eberhardt; H P Hollenbach; B Tomandl; W J Huk
Journal:  Eur Radiol       Date:  1997       Impact factor: 5.315

9.  MR fingerprinting using fast imaging with steady state precession (FISP) with spiral readout.

Authors:  Yun Jiang; Dan Ma; Nicole Seiberlich; Vikas Gulani; Mark A Griswold
Journal:  Magn Reson Med       Date:  2014-12-09       Impact factor: 4.668

Review 10.  Rapid gradient-echo imaging.

Authors:  Brian A Hargreaves
Journal:  J Magn Reson Imaging       Date:  2012-10-23       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.