Literature DB >> 11815347

Agreement in assessing optic discs with a digital stereoscopic optic disc camera (Discam) and Heidelberg retina tomograph.

Velota C T Sung1, Anna Bhan, Stephen A Vernon.   

Abstract

AIMS: To assess the intraobserver agreement, interobserver agreement, and the agreement between a digital stereo optic disc camera (Discam) and Heidelberg retina tomograph (HRT) in measuring area cup-disc ratio (ACDR) and radial cup-disc ratio (RCDR) by two observers.
METHODS: The optic discs of 78 eyes of 39 people (17 cases of primary open angle glaucoma, eight normal tension glaucoma, two ocular hypertension, and 12 normal subjects) were imaged with Discam and HRT. Two observers independently drew the disc margins on the HRT mean topography images and the disc and cup margins on the Discam images. ACDR and the RCDR at various angles were measured with the two systems. Intraobserver agreement, interobserver agreement, and the agreement between the two systems were assessed by 95% tolerance limit of changes (TC) and intraclass correlation coefficient (ICC).
RESULTS: Eight eyes were excluded due to poor image quality (six Discam and two HRT). 70 eyes were analysed. The intraobserver ACDR agreement was almost perfect in both systems (ICCs = 0.97 and 0.92, and TCs = 11.0% and 15.1% in HRT and Discam respectively). The interobserver ACDR agreement was almost perfect in HRT (ICC = 0.97) and substantial in Discam (ICC = 0.79), (TCs = 10.5% and 24.5% respectively). The ACDR agreement between the two systems was substantial in observer A (ICC = 0.67) and moderate in observer B (ICC = 0.53), (TCs = 24.8% and 46.7% respectively). The HRT measured the ACDR significantly larger than the Discam (p <0.001), and the differences were significantly larger in the glaucomatous group (p <0.001). RCDR agreement between the two systems was fair to substantial in observer A (ICC = 0.36 to 0.74) and slight to moderate in observer B (ICC = 0.12 to 0.45). Both observers achieved the best RCDR agreement between the two systems at the inferior optic disc position.
CONCLUSION: There is almost perfect intraobserver agreement in each system. The interobserver agreement was better with the HRT than the Discam. There was substantial variation in ACDR and RCDR agreement between the two systems measured by the two observers. The variation in ACDR and RCDR measurements between the two systems may be too large for interchangeable use in a clinical setting.

Entities:  

Mesh:

Year:  2002        PMID: 11815347      PMCID: PMC1771020          DOI: 10.1136/bjo.86.2.196

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  21 in total

1.  Expert agreement in evaluating the optic disc for glaucoma.

Authors:  R Varma; W C Steinmann; I U Scott
Journal:  Ophthalmology       Date:  1992-02       Impact factor: 12.079

2.  Variability of expert observers in evaluating the optic disc.

Authors:  P R Lichter
Journal:  Trans Am Ophthalmol Soc       Date:  1976

3.  Reproducibility of topographic measurements of the optic nerve head with laser tomographic scanning.

Authors:  F E Kruse; R O Burk; H E Völcker; G Zinser; U Harbarth
Journal:  Ophthalmology       Date:  1989-09       Impact factor: 12.079

4.  Intraobserver and interobserver agreement in measurement of optic disc characteristics.

Authors:  J M Tielsch; J Katz; H A Quigley; N R Miller; A Sommer
Journal:  Ophthalmology       Date:  1988-03       Impact factor: 12.079

5.  Optic disc cupping as clinically estimated from photographs.

Authors:  B E Klein; S E Moss; Y L Magli; R Klein; J C Johnson; H Roth
Journal:  Ophthalmology       Date:  1987-11       Impact factor: 12.079

6.  Optic disc parameters and onset of glaucomatous field loss. I. Methods and progressive changes in disc morphology.

Authors:  A Sommer; I Pollack; A E Maumenee
Journal:  Arch Ophthalmol       Date:  1979-08

7.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

8.  The measurement of observer agreement for categorical data.

Authors:  J R Landis; G G Koch
Journal:  Biometrics       Date:  1977-03       Impact factor: 2.571

9.  Reproducibility of the optic nerve head topography with a new laser tomographic scanning device.

Authors:  K Rohrschneider; R O Burk; F E Kruse; H E Völcker
Journal:  Ophthalmology       Date:  1994-06       Impact factor: 12.079

10.  The mode of progressive disc cupping in ocular hypertension and glaucoma.

Authors:  J E Pederson; D R Anderson
Journal:  Arch Ophthalmol       Date:  1980-03
View more
  10 in total

1.  Comparison of optic nerve head assessment with a digital stereoscopic camera (discam), scanning laser ophthalmoscopy, and stereophotography.

Authors:  Anthony J Correnti; Gadi Wollstein; Lori Lyn Price; Joel S Schuman
Journal:  Ophthalmology       Date:  2003-08       Impact factor: 12.079

2.  Agreement between optical coherence tomography and digital stereophotography in vertical cup-to-disc ratio measurement.

Authors:  Giacomo Savini; Edgar M Espana; Ana Carolina Acosta; Michele Carbonelli; Costantino Bellusci; Piero Barboni
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2008-10-29       Impact factor: 3.117

Review 3.  Test-retest variability in structural parameters measured with glaucoma imaging devices.

Authors:  Makoto Araie
Journal:  Jpn J Ophthalmol       Date:  2012-11-09       Impact factor: 2.447

4.  The relationship between cup-to-disc ratio and estimated number of retinal ganglion cells.

Authors:  Andrew J Tatham; Robert N Weinreb; Linda M Zangwill; Jeffrey M Liebmann; Christopher A Girkin; Felipe A Medeiros
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-05-07       Impact factor: 4.799

5.  Agreement among ophthalmologists in marking the optic disc and optic cup in fundus images.

Authors:  Ahmed Almazroa; Sami Alodhayb; Essameldin Osman; Eslam Ramadan; Mohammed Hummadi; Mohammed Dlaim; Muhannad Alkatee; Kaamran Raahemifar; Vasudevan Lakshminarayanan
Journal:  Int Ophthalmol       Date:  2016-08-30       Impact factor: 2.031

6.  Agreement in assessing cup-to-disc ratio measurement among stereoscopic optic nerve head photographs, HRT II, and Stratus OCT.

Authors:  Stella N Arthur; Aric J Aldridge; Julio De León-Ortega; Gerald McGwin; Aiyuan Xie; Christopher A Girkin
Journal:  J Glaucoma       Date:  2006-06       Impact factor: 2.503

7.  Spectral domain optical coherence tomography in glaucoma: qualitative and quantitative analysis of the optic nerve head and retinal nerve fiber layer (an AOS thesis).

Authors:  Teresa C Chen
Journal:  Trans Am Ophthalmol Soc       Date:  2009-12

8.  Agreement in identification of glaucomatous progression between the optic disc photography and Heidelberg retina tomography in young glaucomatous patients.

Authors:  Paraskeva Hentova-Sencanic; Ivan Sencanic; Goran Trajković; Marija Bozic; Nevena Bjelovic
Journal:  Int J Ophthalmol       Date:  2014-06-18       Impact factor: 1.779

9.  [Screening for diabetic retinopathy and optic disc topography with the "retinal thickness analyzer" (RTA)].

Authors:  A S Neubauer; C Chryssafis; M Thiel; S Priglinger; U Welge-Lüssen; A Kampik
Journal:  Ophthalmologe       Date:  2005-03       Impact factor: 1.059

10.  Clinical measurement and categorization of optic disc in glaucoma patients.

Authors:  Harsha B Laxmana Rao; G C Sekhar; Ganesh J Babu; Rajul S Parikh
Journal:  Indian J Ophthalmol       Date:  2009 Sep-Oct       Impact factor: 1.848

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.