Literature DB >> 3174002

Intraobserver and interobserver agreement in measurement of optic disc characteristics.

J M Tielsch1, J Katz, H A Quigley, N R Miller, A Sommer.   

Abstract

Reliable measures of optic nerve status are important parameters for epidemiologic and clinical studies of glaucoma. Stereo fundus photography has been used to reduce interobserver variation, but little data have been reported quantifying the level of agreement in these situations. This article examines chance-corrected intraobserver and interobserver agreement for horizontal and vertical cup:disc ratios and width of the narrowest remaining neuroretinal rim on stereo, color, fundus photographs. Intraobserver agreement was substantial to almost perfect for both readers (kappas between 0.82 and 0.86 for horizontal and vertical cup:disc ratios and 0.71 for the neuroretinal rim). Interobserver agreement was also substantial (kappas of 0.71 for horizontal cup:disc ratio, 0.74 for vertical cup:disc ratio, and 0.58 for the neuroretinal rim). Both intraobserver and interobserver agreement were best for glaucoma patients followed by ocular hypertensives and controls. Dichotimizing cup:disc ratios into suspicious or not suspicious using a range of cutoff points (greater than or equal to 0.5, greater than or equal to 0.6, and greater than or equal to 0.7 disc diameters [DD]) had little effect on agreement levels. Estimation of the status of the optic nerve is complex, requiring judgment about the shape and structure of the cup. Agreement is optimized by using stereo photographs, using the same observer and, when evaluating progression, comparing photographs from different points in time at a single sitting.

Entities:  

Mesh:

Year:  1988        PMID: 3174002     DOI: 10.1016/s0161-6420(88)33177-5

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  54 in total

1.  Comparison between laser scanning tomography and computerised image analysis of the optic disc.

Authors:  A Azuara-Blanco; G L Spaeth; J Nicholl; I M Lanzl; J J Augsburger
Journal:  Br J Ophthalmol       Date:  1999-03       Impact factor: 4.638

2.  A new digital optic disc stereo camera: intraobserver and interobserver repeatability of optic disc measurements.

Authors:  G N Shuttleworth; C H Khong; J P Diamond
Journal:  Br J Ophthalmol       Date:  2000-04       Impact factor: 4.638

3.  Pharmacological mydriasis and optic disc examination.

Authors:  J F Kirwan; P Gouws; A E Linnell; J Crowston; C Bunce
Journal:  Br J Ophthalmol       Date:  2000-08       Impact factor: 4.638

4.  Ability of cirrus HD-OCT optic nerve head parameters to discriminate normal from glaucomatous eyes.

Authors:  Jean-Claude Mwanza; Jonathan D Oakley; Donald L Budenz; Douglas R Anderson
Journal:  Ophthalmology       Date:  2010-10-28       Impact factor: 12.079

5.  Single-nucleotide polymorphisms and glaucoma severity.

Authors:  Catey Bunce; Roger A Hitchings; Shomi S Bhattacharya; Ordan J Lehmann
Journal:  Am J Hum Genet       Date:  2003-06       Impact factor: 11.025

6.  Comparison of optic nerve head assessment with a digital stereoscopic camera (discam), scanning laser ophthalmoscopy, and stereophotography.

Authors:  Anthony J Correnti; Gadi Wollstein; Lori Lyn Price; Joel S Schuman
Journal:  Ophthalmology       Date:  2003-08       Impact factor: 12.079

7.  Automated segmentation of neural canal opening and optic cup in 3D spectral optical coherence tomography volumes of the optic nerve head.

Authors:  Zhihong Hu; Michael D Abràmoff; Young H Kwon; Kyungmoo Lee; Mona K Garvin
Journal:  Invest Ophthalmol Vis Sci       Date:  2010-06-16       Impact factor: 4.799

8.  Effect of Refractive Status and Axial Length on Peripapillary Retinal Nerve Fibre Layer Thickness: An Analysis Using 3D OCT.

Authors:  V Sowmya; V R Venkataramanan; Vishnu Prasad
Journal:  J Clin Diagn Res       Date:  2015-09-01

9.  Digitizing stereoscopic optic nerve head photographs for storage and viewing using a personal computer.

Authors:  Ronit Nesher; Ioannis Zacharopoulos; Ehud I Assia; Joel S Schuman
Journal:  Ophthalmic Surg Lasers Imaging       Date:  2005 Jul-Aug

10.  Diagnostic capability of peripapillary retinal thickness in glaucoma using 3D volume scans.

Authors:  Huseyin Simavli; Christian John Que; Mustafa Akduman; Jennifer L Rizzo; Edem Tsikata; Johannes F de Boer; Teresa C Chen
Journal:  Am J Ophthalmol       Date:  2014-12-09       Impact factor: 5.258

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.