Literature DB >> 12917163

Comparison of optic nerve head assessment with a digital stereoscopic camera (discam), scanning laser ophthalmoscopy, and stereophotography.

Anthony J Correnti1, Gadi Wollstein, Lori Lyn Price, Joel S Schuman.   

Abstract

PURPOSE: To compare computer-assisted planimetry using the Discam system (Marcher Enterprises Ltd., Hereford, UK), confocal scanning laser ophthalmoscopy (CSLO), and stereoscopic disc photography with respect to optic nerve head (ONH) measurements and glaucoma status.
DESIGN: Comparative, observational case series and interobserver variability study.
METHODS: Three hundred eighty-six eyes of 233 consecutive subjects were imaged with the Discam, and a subset underwent ONH evaluation with CSLO (n = 297), stereoscopic photography (n = 233), or both. Subjects were classified into normal, glaucoma suspect, and glaucoma groups based on clinical findings of slit-lamp disc examination and visual field testing. Agreement of cup-to-disc ratio measurements among the three technologies was assessed by the intraclass correlation coefficient (ICC) and areas under the receiver operator characteristic (AROC) curves. MAIN OUTCOME MEASURES: Cup-to-disc ratio as measured by Discam, CSLO, and stereography.
RESULTS: Intraclass correlation coefficients calculated using the two-way random effects model for comparing Discam, CSLO, and stereography among cup-to-disc area ratio, vertical cup-to-disc ratio, and horizontal cup-to-disc ratio were 0.46 to 0.53. The ICC was higher for eyes with larger optic discs (0.51) than those with smaller ones (0.32). The ICC calculated using the fixed effects model for the Discam and CSLO comparison was 0.72. Areas under the receiver operator characteristic curves were 0.67 to 0.80 among the three technologies comparing normal with glaucomatous eyes. In general, there was no statistically significant difference between techniques with respect to sensitivity and specificity of glaucoma detection.
CONCLUSIONS: There is good agreement between ONH measurements obtained by Discam, CSLO, and stereography; however, the results are not interchangeable. Similar AROC curve values among all three techniques imply that the Discam, CSLO, and stereography perform equally for the determination of glaucoma status.

Entities:  

Mesh:

Year:  2003        PMID: 12917163      PMCID: PMC1939717          DOI: 10.1016/S0161-6420(03)00496-2

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  18 in total

1.  A new digital optic disc stereo camera: intraobserver and interobserver repeatability of optic disc measurements.

Authors:  G N Shuttleworth; C H Khong; J P Diamond
Journal:  Br J Ophthalmol       Date:  2000-04       Impact factor: 4.638

Review 2.  Intraclass correlations: uses in assessing rater reliability.

Authors:  P E Shrout; J L Fleiss
Journal:  Psychol Bull       Date:  1979-03       Impact factor: 17.737

3.  Intraobserver and interobserver agreement in measurement of optic disc characteristics.

Authors:  J M Tielsch; J Katz; H A Quigley; N R Miller; A Sommer
Journal:  Ophthalmology       Date:  1988-03       Impact factor: 12.079

4.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

5.  Agreement in assessing optic discs with a digital stereoscopic optic disc camera (Discam) and Heidelberg retina tomograph.

Authors:  Velota C T Sung; Anna Bhan; Stephen A Vernon
Journal:  Br J Ophthalmol       Date:  2002-02       Impact factor: 4.638

6.  Neuroretinal rim areas and visual field indices in glaucoma.

Authors:  P J Airaksinen; S M Drance; G R Douglas; M Schulzer
Journal:  Am J Ophthalmol       Date:  1985-02-15       Impact factor: 5.258

7.  Identification of early glaucoma cases with the scanning laser ophthalmoscope.

Authors:  G Wollstein; D F Garway-Heath; R A Hitchings
Journal:  Ophthalmology       Date:  1998-08       Impact factor: 12.079

8.  Chronic human glaucoma causing selectively greater loss of large optic nerve fibers.

Authors:  H A Quigley; G R Dunkelberger; W R Green
Journal:  Ophthalmology       Date:  1988-03       Impact factor: 12.079

9.  Clinically detectable nerve fiber atrophy precedes the onset of glaucomatous field loss.

Authors:  A Sommer; J Katz; H A Quigley; N R Miller; A L Robin; R C Richter; K A Witt
Journal:  Arch Ophthalmol       Date:  1991-01

10.  Progression of disc and field damage in early glaucoma.

Authors:  T G Zeyen; J Caprioli
Journal:  Arch Ophthalmol       Date:  1993-01
View more
  13 in total

1.  [Measurement of the disc area by indirect ophthalmoscopy].

Authors:  M Haustein; E Schmidt; E Spörl; L E Pillunat; A G Böhm
Journal:  Ophthalmologe       Date:  2009-02       Impact factor: 1.059

2.  Agreement between optical coherence tomography and digital stereophotography in vertical cup-to-disc ratio measurement.

Authors:  Giacomo Savini; Edgar M Espana; Ana Carolina Acosta; Michele Carbonelli; Costantino Bellusci; Piero Barboni
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2008-10-29       Impact factor: 3.117

3.  Intraobserver and interobserver agreement of computer software-assisted optic nerve head photoplanimetry.

Authors:  Masaki Tanito; Takeshi Sagara; Michiya Takamatsu; Yoshiaki Kiuchi; Toshiaki Nakagawa; Yasuyuki Fujita; Akihiro Ohira
Journal:  Jpn J Ophthalmol       Date:  2013-10-08       Impact factor: 2.447

Review 4.  Test-retest variability in structural parameters measured with glaucoma imaging devices.

Authors:  Makoto Araie
Journal:  Jpn J Ophthalmol       Date:  2012-11-09       Impact factor: 2.447

5.  Agreement in assessing cup-to-disc ratio measurement among stereoscopic optic nerve head photographs, HRT II, and Stratus OCT.

Authors:  Stella N Arthur; Aric J Aldridge; Julio De León-Ortega; Gerald McGwin; Aiyuan Xie; Christopher A Girkin
Journal:  J Glaucoma       Date:  2006-06       Impact factor: 2.503

6.  Non-physician grader reliability in measuring morphological features of the optic nerve head in stereo digital images.

Authors:  Victoria Addis; Enny Oyeniran; Ebenezer Daniel; Rebecca Salowe; Richard Zorger; Roy Lee; Maxwell Pistilli; Maureen Maguire; Qi Cui; Eydie Miller-Ellis; Joan M O'Brien; Prithvi S Sankar
Journal:  Eye (Lond)       Date:  2019-01-11       Impact factor: 3.775

7.  Detection of optic nerve head neural canal opening within histomorphometric and spectral domain optical coherence tomography data sets.

Authors:  Nicholas G Strouthidis; Hongli Yang; Brad Fortune; J Crawford Downs; Claude F Burgoyne
Journal:  Invest Ophthalmol Vis Sci       Date:  2008-08-08       Impact factor: 4.799

8.  Comparison of disc damage likelihood scale, cup to disc ratio, and Heidelberg retina tomograph in the diagnosis of glaucoma.

Authors:  H V Danesh-Meyer; B J Gaskin; T Jayusundera; M Donaldson; G D Gamble
Journal:  Br J Ophthalmol       Date:  2006-04       Impact factor: 4.638

9.  Can Visual Field Progression be Predicted by Confocal Scanning Laser Ophthalmoscopic Imaging of the Optic Nerve Head in Glaucoma? (An American Ophthalmological Society Thesis).

Authors:  John Danias; Janet Serle
Journal:  Trans Am Ophthalmol Soc       Date:  2015

Review 10.  Teleglaucoma: improving access and efficiency for glaucoma care.

Authors:  Faazil Kassam; Kanagasingam Yogesan; Enitan Sogbesan; Louis R Pasquale; Karim F Damji
Journal:  Middle East Afr J Ophthalmol       Date:  2013 Apr-Jun
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.