[Screening for diabetic retinopathy and optic disc topography with the "retinal thickness analyzer" (RTA)].

A S Neubauer1, C Chryssafis, M Thiel, S Priglinger, U Welge-Lüssen, A Kampik.   

Abstract

BACKGROUND: The RTA features a fundus photography mode and optic disc topography. Those two new modes were investigated regarding their clinical use.
METHODS: First, the combination of wide-field photography with a retinal thickness map was assessed for tele-screening for diabetic retinopathy in 31 eyes. Second, normal values of the optic disc were collected on 30 non-glaucomatous probands in the non-mydriatic mode and compared to the results of the mydriatic mode, for which reproducibility was also investigated.
RESULTS: For diabetic retinopathy, the RTA yielded mean 93% sensitivity for proliferative diabetic retinopathy and 100% sensitivity for detecting diabetic macular edema compared to clinical examination at specificities ranging from 58 to 96%. Regarding the measurements of the optic disc, the normal values in mydriasis coincided with those in miosis in all but 4 of 12 parameters.
CONCLUSIONS: The RTA is suitable for application in tele-screening for diabetic retinopathy. The topography of the optic disc is highly reproducible and may be used for glaucoma diagnostics.

Entities:  

Mesh:

Year:  2005        PMID: 15351898     DOI: 10.1007/s00347-004-1098-x

Source DB:  PubMed          Journal:  Ophthalmologe        ISSN: 0941-293X            Impact factor:   1.059


  14 in total

1.  Comparison of foveal thickness measured with the retinal thickness analyzer and optical coherence tomography.

Authors:  A S Neubauer; S Priglinger; S Ullrich; M Bechmann; M J Thiel; M W Ulbig; A Kampik
Journal:  Retina       Date:  2001       Impact factor: 4.256

2.  A new method for rapid mapping of the retinal thickness at the posterior pole.

Authors:  R Zeimer; M Shahidi; M Mori; S Zou; S Asrani
Journal:  Invest Ophthalmol Vis Sci       Date:  1996-09       Impact factor: 4.799

3.  Feasibility test of a new method to measure retinal thickness noninvasively.

Authors:  R C Zeimer; M T Mori; B Khoobehi
Journal:  Invest Ophthalmol Vis Sci       Date:  1989-10       Impact factor: 4.799

4.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

5.  Retinal thickness study with optical coherence tomography in patients with diabetes.

Authors:  Hortensia Sánchez-Tocino; Aurora Alvarez-Vidal; Miguel J Maldonado; Javier Moreno-Montañés; Alfredo García-Layana
Journal:  Invest Ophthalmol Vis Sci       Date:  2002-05       Impact factor: 4.799

6.  Agreement in assessing optic discs with a digital stereoscopic optic disc camera (Discam) and Heidelberg retina tomograph.

Authors:  Velota C T Sung; Anna Bhan; Stephen A Vernon
Journal:  Br J Ophthalmol       Date:  2002-02       Impact factor: 4.638

7.  Intraobserver and interobserver reproducibility in the evaluation of optic disc stereometric parameters by Heidelberg Retina Tomograph.

Authors:  Stefano Miglior; Elena Albé; Magda Guareschi; Luca Rossetti; Nicola Orzalesi
Journal:  Ophthalmology       Date:  2002-06       Impact factor: 12.079

8.  Photocoagulation for diabetic macular edema. Early Treatment Diabetic Retinopathy Study report number 1. Early Treatment Diabetic Retinopathy Study research group.

Authors: 
Journal:  Arch Ophthalmol       Date:  1985-12

9.  Evaluation of a district-wide screening programme for diabetic retinopathy utilizing trained optometrists using slit-lamp and Volk lenses.

Authors:  S A Hulme; A Tin-U; K J Hardy; P W Joyce
Journal:  Diabet Med       Date:  2002-09       Impact factor: 4.359

Review 10.  Screening for diabetic retinopathy.

Authors:  D R Owens; J Dolben; S Young; R E Ryder; I R Jones; J Vora; D Jones; D Morsman; T M Hayes
Journal:  Diabet Med       Date:  1991       Impact factor: 4.359

View more
  2 in total

1.  Repeatability and reproducibility of optic nerve head topography using the retinal thickness analyzer.

Authors:  Esther M Hoffmann; Felipe A Medeiros; Christina Kramann; Norbert Pfeiffer; Franz H Grus
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2005-08-05       Impact factor: 3.117

Review 2.  Algorithms for the automated detection of diabetic retinopathy using digital fundus images: a review.

Authors:  Oliver Faust; Rajendra Acharya U; E Y K Ng; Kwan-Hoong Ng; Jasjit S Suri
Journal:  J Med Syst       Date:  2010-04-06       Impact factor: 4.460

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.