Literature DB >> 16200481

Radiation-reducing planning of cardiac catheterisation.

E Kuon1, J B Dahm, D M Robinson, K Empen, M Günther, W Wucherer.   

Abstract

Any radiation exposition for medical purposes should be kept as low as is reasonably achievable. Mean patient radiation exposure of diagnostic cardiac catheterisation is high (16-106 Gy x cm2) and for this reason the International Commission on Radiological Protection (ICRP) recommends credentialing radiation protection training programmes. Twenty cardiologists each documented various dose parameters of 10 cardiac catheterisations, before and after a 90-minute mini-course of the ELICIT study group ("Encourage to Less Irradiating Cardiologic Interventional Techniques"), and could achieve a reduction of the mean dose-area product by 15.9+/-9.0 Gy x cm2, equivalent to 47%. The presented radiation-reducing planning of invasive cardiac catheterisation for this reason is the first one validated in clinical routine and consists of 6 standard runs--one for the left ventricle, 3 and 2 for the left (LCA) and right coronary artery (RCA), respectively--depending on anatomy and findings supplemented by 1...4 special projections. The caudal posteroanterior (PA) view documents the left coronary main stem, proximal and distal left anterior descending artery (LAD), and proximal and mid circumflex segments. The cranial PA view however is suitable for the left coronary orifice, circumflex periphery, LAD, all diagonal bifurcations, and collateral pathways towards the RCA. LCA standard angiography is completed by lateral 90 degrees/0 degrees left anterior oblique (LAO) angulation. The 60 degrees/0 degrees LAO angulation visualises the right posterolateral artery (RPL) and the RCA to its bifurcation. The more proximal one finds the bifurcation, the more the second standard cranial PA view for RCA should vary towards the cranial right anterior oblique (RAO) and finally 30 degrees/0 degrees RAO view. The efficiency of these less-irradiating angulations are improved by radiation-reducing techniques as follows: restriction to essential radiographic frames and runs, consistent collimation to the region of interest--particularly during coronary intubation--, adequate instead of best possible image quality, short skin-to-image-intensifier distance, inspiration during radiography, preference for projections that rotate out the spine, optimisation of fluoroscopy time, well-experienced and well-rested interventionists.

Entities:  

Mesh:

Year:  2005        PMID: 16200481     DOI: 10.1007/s00392-005-0277-3

Source DB:  PubMed          Journal:  Z Kardiol        ISSN: 0300-5860


  43 in total

1.  Radiation exposure to medical staff in interventional and cardiac radiology.

Authors:  E Vañó; L González; E Guibelalde; J M Fernández; J I Ten
Journal:  Br J Radiol       Date:  1998-09       Impact factor: 3.039

2.  Significant reduction of radiation exposure to operator and staff during cardiac interventions by analysis of radiation leakage and improved lead shielding.

Authors:  Eberhard Kuon; Moritz Schmitt; Johannes B Dahm
Journal:  Am J Cardiol       Date:  2002-01-01       Impact factor: 2.778

Review 3.  Radiation dose in computed tomography of the heart.

Authors:  Richard L Morin; Thomas C Gerber; Cynthia H McCollough
Journal:  Circulation       Date:  2003-02-18       Impact factor: 29.690

4.  Radiation doses to patients undergoing coronary angiography and percutaneous transluminal coronary angioplasty.

Authors:  M G Delichas; K Psarrakos; E Molyvda-Athanassopoulou; G Giannoglou; K Hatziioannou; E Papanastassiou
Journal:  Radiat Prot Dosimetry       Date:  2003       Impact factor: 0.972

5.  [Personal operator dose in invasive cardiology as a function of body height and tube angulation].

Authors:  E Kuon; K Empen; G Reuter; J B Dahm
Journal:  Rofo       Date:  2004-05

6.  [Body build and radiation exposure in static roentgen studies (I): A contribution for determining a national reference dose value. Promoted by the Federal Office for Radiation Protection (St.Sch 4163)].

Authors:  W Golder; G Weiner
Journal:  Rofo       Date:  2001-06

7.  Does cardiologist- or radiographer-operated fluoroscopy and image acquisition influence optimization of patient radiation exposure during routine coronary angiography?

Authors:  W R Arthur; J Dhawan; M S Norell; A J Hunter; A L Clark
Journal:  Br J Radiol       Date:  2002-09       Impact factor: 3.039

Review 8.  [Prognostic value of noninvasive coronary plaque burden quantification in patients with risk factors].

Authors:  S Möhlenkamp; A Schmermund; G Kerkhoff; T Budde; R Erbel
Journal:  Z Kardiol       Date:  2003-05

9.  Effective techniques for reduction of radiation dosage to patients undergoing invasive cardiac procedures.

Authors:  E Kuon; C Glaser; J B Dahm
Journal:  Br J Radiol       Date:  2003-06       Impact factor: 3.039

Review 10.  [Imaging of coronary atherosclerotic plaque].

Authors:  P Schoenhagen; R D White; S E Nissen; E M Tuzcu
Journal:  Z Kardiol       Date:  2003-06
View more
  3 in total

1.  Assessment of modified Blalock-Taussig shunt in children with congenital heart disease using multidetector-row computed tomography.

Authors:  Manal Mohamed Helmy Nabo; Yasunobu Hayabuchi; Miki Inoue; Noriko Watanabe; Miho Sakata; Shoji Kagami
Journal:  Heart Vessels       Date:  2010-09-28       Impact factor: 2.037

2.  Imaging of aortopulmonary collateral arteries with high-resolution multidetector CT.

Authors:  Gerald F Greil; Max Schoebinger; Axel Kuettner; Juergen F Schaefer; Florian Dammann; Claus D Claussen; Michael Hofbeck; Hans-Peter Meinzer; Ludger Sieverding
Journal:  Pediatr Radiol       Date:  2006-03-23

3.  Predictors of Excess Patient Radiation Exposure During Chronic Total Occlusion Coronary Intervention: Insights From a Contemporary Multicentre Registry.

Authors:  Georgios E Christakopoulos; Georgios Christopoulos; Dimitri Karmpaliotis; Khaldoon Alaswad; Robert W Yeh; Farouc A Jaffer; Michael R Wyman; William L Lombardi; Muhammad Nauman J Tarar; J Aaron Grantham; David E Kandzari; Nicholas Lembo; Jeffrey W Moses; Ajay J Kirtane; Manish Parikh; Philip Green; Matthew Finn; Santiago Garcia; Anthony H Doing; Raja Hatem; Craig A Thompson; Subhash Banerjee; Emmanouil S Brilakis
Journal:  Can J Cardiol       Date:  2016-11-11       Impact factor: 5.223

  3 in total