Aju P Pazhenkottil1, Bernhard A Herzog, Lars Husmann, Ronny R Buechel, Irene A Burger, Ines Valenta, Ulf Landmesser, Christophe A Wyss, Philipp A Kaufmann.   

Abstract

PURPOSE: To validate a new low-dose and rapid stepwise individualized algorithm for non-invasive assessment of ischemic coronary artery disease by sequential use of prospectively ECG-triggered low-dose CT coronary angiography (CTCA) and low-dose single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI).
METHODS: Forty patients referred for elective invasive coronary angiography (CA) were prospectively enrolled to undergo a comprehensive non-invasive evaluation with low-dose CTCA and a dose-reduced stress/rest SPECT-MPI scan (using dedicated reconstruction algorithms for low count scans). The following algorithm was reviewed: CTCA first, followed by a stress-only MPI if a coronary stenosis (> or = 50% diameter narrowing) or equivocal findings were observed. Only abnormal stress MPI scans were followed by rest MPI. The accuracy of the individualized algorithm to predict coronary revascularization and its mean effective radiation dose were assessed.
RESULTS: CTCA documented CAD in 18 and equivocal findings in two patients, thus, requiring additional stress MPI scans. Of these, 16 were abnormal, therefore requiring a rest MPI scan, revealing ischemia in 15 patients. Sensitivity, specificity, negative and positive predictive value, and accuracy of the individualized algorithm for predicting coronary revascularization was 93.3%, 96.0%, 96.0%, 93.3% and 95.0% on a per-patient base. The mean effective radiation dose was significantly lower for the individualized (4.8 +/- 3.4 mSv) versus the comprehensive method (8.1 +/- 1.5 mSv) resulting in a total population radiation dose reduction of 132.6 mSv.
CONCLUSION: This new individualized low-dose algorithm allows rapid and accurate prediction of invasive CA findings and of treatment decision with minimized radiation dose.

Entities:  

Mesh:

Year:  2009        PMID: 19789871     DOI: 10.1007/s00259-009-1273-z

Source DB:  PubMed          Journal:  Eur J Nucl Med Mol Imaging        ISSN: 1619-7070            Impact factor:   9.236


  25 in total

1.  Noninvasive coronary angiography by retrospectively ECG-gated multislice spiral CT.

Authors:  S Achenbach; S Ulzheimer; U Baum; M Kachelriess; D Ropers; T Giesler; W Bautz; W G Daniel; W A Kalender; W Moshage
Journal:  Circulation       Date:  2000-12-05       Impact factor: 29.690

2.  Noninvasive coronary angiography--an acceptable alternative?

Authors:  S Achenbach; W G Daniel
Journal:  N Engl J Med       Date:  2001-12-27       Impact factor: 91.245

3.  Relationship between noninvasive coronary angiography with multi-slice computed tomography and myocardial perfusion imaging.

Authors:  Joanne D Schuijf; William Wijns; J Wouter Jukema; Douwe E Atsma; Albert de Roos; Hildo J Lamb; Marcel P M Stokkel; Petra Dibbets-Schneider; Isabel Decramer; Pieter De Bondt; Ernst E van der Wall; Piet K Vanhoenacker; Jeroen J Bax
Journal:  J Am Coll Cardiol       Date:  2006-11-28       Impact factor: 24.094

Review 4.  Cardiac computed tomography: indications, applications, limitations, and training requirements: report of a Writing Group deployed by the Working Group Nuclear Cardiology and Cardiac CT of the European Society of Cardiology and the European Council of Nuclear Cardiology.

Authors:  Stephen Schroeder; Stephan Achenbach; Frank Bengel; Christof Burgstahler; Filippo Cademartiri; Pim de Feyter; Richard George; Philipp Kaufmann; Andreas F Kopp; Juhani Knuuti; Dieter Ropers; Joanne Schuijf; Laurens F Tops; Jeroen J Bax
Journal:  Eur Heart J       Date:  2007-12-15       Impact factor: 29.983

5.  Low-dose CT coronary angiography using prospective ECG-triggering: impact of mean heart rate and heart rate variability on image quality.

Authors:  Bernhard A Herzog; Lars Husmann; Nina Burkhard; Ines Valenta; Oliver Gaemperli; Fuminari Tatsugami; Christophe A Wyss; Uif Landmesser; Philipp A Kaufmann
Journal:  Acad Radiol       Date:  2009-01       Impact factor: 3.173

6.  Validation of a new cardiac image fusion software for three-dimensional integration of myocardial perfusion SPECT and stand-alone 64-slice CT angiography.

Authors:  Oliver Gaemperli; Tiziano Schepis; Victor Kalff; Mehdi Namdar; Ines Valenta; Laurent Stefani; Lotus Desbiolles; Sebastian Leschka; Lars Husmann; Hatem Alkadhi; Philipp A Kaufmann
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-01-24       Impact factor: 9.236

7.  Feasibility and diagnostic accuracy of a gated SPECT early-imaging protocol: a multicenter study of the Myoview Imaging Optimization Group.

Authors:  Assuero Giorgetti; Massimiliano Rossi; Mario Stanislao; Guido Valle; Pietro Bertolaccini; Alberto Maneschi; Raffaele Giubbini; Maria Luisa De Rimini; Marco Mazzanti; Mario Cappagli; Elisa Milan; Duccio Volterrani; Paolo Marzullo
Journal:  J Nucl Med       Date:  2007-09-14       Impact factor: 10.057

8.  Half-time SPECT myocardial perfusion imaging with attenuation correction.

Authors:  Iftikhar Ali; Terrence D Ruddy; Abdulaziz Almgrahi; Frank G Anstett; R Glenn Wells
Journal:  J Nucl Med       Date:  2009-03-16       Impact factor: 10.057

9.  The effect of beta-blockers on the diagnostic accuracy of vasodilator pharmacologic SPECT myocardial perfusion imaging.

Authors:  Andrew J Yoon; Rowlens M Melduni; Shelly-Ann Duncan; Robert J Ostfeld; Mark I Travin
Journal:  J Nucl Cardiol       Date:  2009-03-06       Impact factor: 5.952

10.  Impact of ethnicity and gender differences on angiographic coronary artery disease prevalence and in-hospital mortality in the American College of Cardiology-National Cardiovascular Data Registry.

Authors:  Leslee J Shaw; Richard E Shaw; C Noel Bairey Merz; Ralph G Brindis; Lloyd W Klein; Brahmajee Nallamothu; Pamela S Douglas; Ronald J Krone; Charles R McKay; Peter C Block; Kathleen Hewitt; William S Weintraub; Eric D Peterson
Journal:  Circulation       Date:  2008-03-31       Impact factor: 29.690

View more
  9 in total

1.  Sequential SPECT/CT imaging for detection of coronary artery disease in a large cohort: evaluation of the need for additional imaging and radiation exposure.

Authors:  Elsemiek M Engbers; Jorik R Timmer; Jan Paul Ottervanger; Mohamed Mouden; Ad H J Oostdijk; Siert Knollema; Pieter L Jager
Journal:  J Nucl Cardiol       Date:  2015-09-22       Impact factor: 5.952

2.  Nuclear cardiology at the door of a new era: better to save mSv or to reduce imaging time?

Authors:  Assuero Giorgetti; Dario Genovesi; Paolo Marzullo
Journal:  Eur J Nucl Med Mol Imaging       Date:  2012-12       Impact factor: 9.236

Review 3.  Assessment of myocardial perfusion and function with PET and PET/CT.

Authors:  Mouaz H Al-Mallah; Arkadiusz Sitek; Stephen C Moore; Marcelo Di Carli; Sharmila Dorbala
Journal:  J Nucl Cardiol       Date:  2010-06       Impact factor: 5.952

4.  Corrected coronary opacification decrease from coronary computed tomography angiography: Validation with quantitative 13N-ammonia positron emission tomography.

Authors:  Dominik C Benz; Christoph Gräni; Paola Ferro; Luis Neumeier; Michael Messerli; Mathias Possner; Olivier F Clerc; Catherine Gebhard; Oliver Gaemperli; Aju P Pazhenkottil; Philipp A Kaufmann; Ronny R Buechel
Journal:  J Nucl Cardiol       Date:  2017-07-06       Impact factor: 5.952

5.  Hybrid cardiac imaging: SPECT/CT and PET/CT. A joint position statement by the European Association of Nuclear Medicine (EANM), the European Society of Cardiac Radiology (ESCR) and the European Council of Nuclear Cardiology (ECNC).

Authors:  Albert Flotats; Juhani Knuuti; Matthias Gutberlet; Claudio Marcassa; Frank M Bengel; Philippe A Kaufmann; Michael R Rees; Birger Hesse
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-01       Impact factor: 9.236

6.  Ultra high speed SPECT bone imaging enabled by a deep learning enhancement method: a proof of concept.

Authors:  Boyang Pan; Na Qi; Qingyuan Meng; Jiachen Wang; Siyue Peng; Chengxiao Qi; Nan-Jie Gong; Jun Zhao
Journal:  EJNMMI Phys       Date:  2022-06-13

7.  Temporal evolution of administered activity in cardiac gated SPECT and patients' effective dose: analysis of an historical series.

Authors:  C Marcassa; O Zoccarato; P Calza; R Campini
Journal:  Eur J Nucl Med Mol Imaging       Date:  2012-11-21       Impact factor: 9.236

8.  Impact of cardiac hybrid single-photon emission computed tomography/computed tomography imaging on choice of treatment strategy in coronary artery disease.

Authors:  Aju P Pazhenkottil; Rene N Nkoulou; Jelena-Rima Ghadri; Bernhard A Herzog; Silke M Küest; Lars Husmann; Mathias Wolfrum; Robert Goetti; Ronny R Buechel; Oliver Gaemperli; Thomas F Lüscher; Philipp A Kaufmann
Journal:  Eur Heart J       Date:  2011-07-30       Impact factor: 29.983

9.  Clinical impact of low-radiation computed tomography coronary angiography diagnosis for coronary artery stenosis: Study Protocol.

Authors:  Jian-Jun Li; Ming Zeng
Journal:  Medicine (Baltimore)       Date:  2019-11       Impact factor: 1.817

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.