Literature DB >> 14534803

Preliminary reference levels in interventional cardiology.

V Neofotistou1, E Vano, R Padovani, J Kotre, A Dowling, M Toivonen, S Kottou, V Tsapaki, S Willis, G Bernardi, K Faulkner.   

Abstract

This article describes the European DIMOND approach to defining reference levels (RLs) for radiation doses delivered to patients during two types of invasive cardiology procedures, namely coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA). Representative centres of six European countries recorded patients' doses in terms of dose-area product (DAP), fluoroscopy time and number of radiographic exposures, using X-ray equipment that has been subject to constancy testing. In addition, a DAP trigger level for cardiac procedures which should alert the operator to possible skin injury, was set to 300 Gyxcm2. The estimation of maximum skin dose was recommended in the event that a DAP trigger level was likely to be exceeded. The proposed RLs for CA and PTCA were for DAP 45 Gyxcm2 and 75 Gyxcm2, for fluoroscopy time 7.5 min and 17 min and for number of frames 1250 and 1300, respectively. The proposed RLs should be considered as a first approach to help in the optimisation of these procedures. More studies are required to establish certain "tolerances" from the proposed levels taking into account the complexity of the procedure and the patient's size.

Entities:  

Mesh:

Year:  2003        PMID: 14534803     DOI: 10.1007/s00330-003-1831-x

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  20 in total

1.  Skin dose and dose-area product values for interventional cardiology procedures.

Authors:  E Vano; L Gonzalez; J I Ten; J M Fernandez; E Guibelalde; C Macaya
Journal:  Br J Radiol       Date:  2001-01       Impact factor: 3.039

Review 2.  Skin injuries from fluoroscopically guided procedures: part 2, review of 73 cases and recommendations for minimizing dose delivered to patient.

Authors:  T R Koenig; F A Mettler; L K Wagner
Journal:  AJR Am J Roentgenol       Date:  2001-07       Impact factor: 3.959

3.  Approaches to establishing reference levels in interventional radiology.

Authors:  E Vañó; L Gonzalez
Journal:  Radiat Prot Dosimetry       Date:  2001       Impact factor: 0.972

4.  A method based on DIMOND quality criteria to evaluate imaging in diagnostic and interventional cardiology.

Authors:  G Bernardi; R Padovani; G Morocutti; L Spedicato; J D Giannuleas; E Neofotistou; A Maginas; J C Goicolea; J McNeill; E Vañó
Journal:  Radiat Prot Dosimetry       Date:  2001       Impact factor: 0.972

5.  Introduction to constancy check protocols in fluoroscopic systems.

Authors:  K Faulkner
Journal:  Radiat Prot Dosimetry       Date:  2001       Impact factor: 0.972

6.  Deterministic effects in interventional radiology.

Authors:  K Faulkner; E Vañó
Journal:  Radiat Prot Dosimetry       Date:  2001       Impact factor: 0.972

7.  Quality criteria for cardiac images in diagnostic and interventional cardiology.

Authors:  G Bernardi; R Padovani; G Morocutti; L Spedicato; J D Giannuleas; E Neofotistou; A Manginas; J C Goicolea; J McNeill; E Vaño; A Marzocchi; V Tsapaki; P M Fioretti; J Malone
Journal:  Br J Radiol       Date:  2001-09       Impact factor: 3.039

8.  The impact of cardiology on the collective effective dose in the North of England.

Authors:  D A Broadhead; C L Chapple; K Faulkner; M L Davies; H McCallum
Journal:  Br J Radiol       Date:  1997-05       Impact factor: 3.039

9.  Dose displays and record keeping.

Authors:  K Faulkner
Journal:  Radiat Prot Dosimetry       Date:  2001       Impact factor: 0.972

10.  Review of patient dosimetry in cardiology.

Authors:  V Neofotistou
Journal:  Radiat Prot Dosimetry       Date:  2001       Impact factor: 0.972

View more
  26 in total

Review 1.  Occupational radiation doses to operators performing fluoroscopically-guided procedures.

Authors:  Kwang Pyo Kim; Donald L Miller; Amy Berrington de Gonzalez; Stephen Balter; Ruth A Kleinerman; Evgenia Ostroumova; Steven L Simon; Martha S Linet
Journal:  Health Phys       Date:  2012-07       Impact factor: 1.316

2.  Do flat detector cardiac X-ray systems convey advantages over image-intensifier-based systems? Study comparing X-ray dose and image quality.

Authors:  Andrew G Davies; Arnold R Cowen; Stephen M Kengyelics; Janet Moore; Mohan U Sivananthan
Journal:  Eur Radiol       Date:  2006-11-18       Impact factor: 5.315

3.  Protective aprons in imaging departments: manufacturer stated lead equivalence values require validation.

Authors:  M Finnerty; P C Brennan
Journal:  Eur Radiol       Date:  2005-03-24       Impact factor: 5.315

4.  How to set up and apply reference levels in fluoroscopy at a national level.

Authors:  A Aroua; H Rickli; J-C Stauffer; P Schnyder; P R Trueb; J-F Valley; P Vock; F R Verdun
Journal:  Eur Radiol       Date:  2006-10-27       Impact factor: 5.315

5.  Impact of biplane versus single-plane imaging on radiation dose, contrast load and procedural time in coronary angioplasty.

Authors:  V Sadick; W Reed; L Collins; N Sadick; R Heard; J Robinson
Journal:  Br J Radiol       Date:  2009-12-17       Impact factor: 3.039

Review 6.  Coronary CT angiography with low radiation dose.

Authors:  Lei Xu; Zhaoqi Zhang
Journal:  Int J Cardiovasc Imaging       Date:  2010-02       Impact factor: 2.357

7.  Reference levels for patient radiation doses in interventional radiology: proposed initial values for U.S. practice.

Authors:  Donald L Miller; Deukwoo Kwon; Grant H Bonavia
Journal:  Radiology       Date:  2009-09-29       Impact factor: 11.105

8.  Summary of the Italian inter-society recommendations for radiation protection optimization in interventional radiology.

Authors:  Gaetano Compagnone; Renato Padovani; Maria Antonietta D'Avanzo; Sveva Grande; Francesco Campanella; Antonella Rosi
Journal:  Radiol Med       Date:  2018-01-06       Impact factor: 3.469

9.  Radiation-reducing planning of cardiac catheterisation.

Authors:  E Kuon; J B Dahm; D M Robinson; K Empen; M Günther; W Wucherer
Journal:  Z Kardiol       Date:  2005-10

10.  Patient Radiation Exposure During Diagnostic and Therapeutic Procedures for Intracranial Aneurysms: A Multicenter Study.

Authors:  Yon Kwon Ihn; Bum-Soo Kim; Jun Soo Byun; Sang Hyun Suh; Yoo Dong Won; Deok Hee Lee; Byung Moon Kim; Young Soo Kim; Pyong Jeon; Chang-Woo Ryu; Sang-Il Suh; Dae Seob Choi; See Sung Choi; Jin Wook Choi; Hyuk Won Chang; Jae-Wook Lee; Sang Heum Kim; Young Jun Lee; Shang Hun Shin; Soo Mee Lim; Woong Yoon; Hae Woong Jeong; Moon Hee Han
Journal:  Neurointervention       Date:  2016-09-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.