Literature DB >> 11482320

A comparison of polyethylene wear in hips with cobalt-chrome or zirconia heads. A prospective, randomised study.

Y H Kim1, J S Kim, S H Cho.   

Abstract

We have reviewed 70 patients with bilateral simultaneous total hip arthroplasties to determine the rate of failure and to compare polyethylene wear and osteolysis between an implant with a cobalt-chrome head and Hylamer liner with that of a zirconia head and Hylamer liner. The mean thickness of the polyethylene liner was 11.0 mm (8.8 to 12.2) in the hip with a zirconia head and 10.7 mm (8.8 to 12.2) in that with a cobalt-chrome head. At follow-up at 6.4 years no acetabular or femoral component had been revised for aseptic loosening and no acetabular or femoral component was loose according to radiological criteria in both the cemented and cementless groups. The mean rate of linear wear and annual wear rate were highest in the 22 mm zirconia femoral head (1.25 mm (SD 1.05) and 0.21 mm (SD 0.18), respectively) and lowest in the 22 mm cobalt-chrome femoral head (0.70 mm (SD 0.39) and 0.12 mm (SD 0.07), respectively). The mean volumetric wear was highest in the 28 mm zirconia femoral head (730.79 mm ) and lowest in the 22 mm cobalt-chrome femoral head (264.67 mm3), but if the results were compared by size of the femoral head and type of material there was no statistical difference (p > 0.05). Sequential measurements of annual wear showed that the zirconia femoral head had a relatively higher rate of penetration than the cobalt-chrome head over the first three years; thereafter the rate of wear was reduced and compared favourably with that of cobalt-chrome heads. There was a statistically significant relationship between the wear of the polyethylene liner and the age of the patient, male gender and the degree of abduction angle of the cup, but not diagnosis, weight, hip score, range of movement, or amount of anteversion. Osteolysis was identified on both sides of the acetabulum in six patients (9%). Of 12 hips with acetabular osteolysis, six had a 28 mm cobalt-chrome femoral head and the remaining six a 28 mm zirconia head. Osteolysis was observed in zones 1A and 7A of the femur in two hips (3%) with a 28 mm zirconia head (cemented hip) and in four (6%) with a 28 mm cobalt-chrome femoral head (cementless hip). Our findings suggest that although the performance of a zirconia femoral head with a Hylamer liner was not statistically different from that of a cobalt-chrome femoral head and Hylamer liner, there was a trend for the zirconia head to be worse than the cobalt-chrome femoral head.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11482320     DOI: 10.1302/0301-620x.83b5.10941

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  14 in total

1.  Increased volumetric wear of polyethylene liners with more than 3 years of shelf-life time.

Authors:  T J S Puolakka; J T Keränen; K A Juhola; K J J Pajamäki; P J Halonen; J K Nevalainen; V Saikko; M U K Lehto; M Järvinen
Journal:  Int Orthop       Date:  2003-04-01       Impact factor: 3.075

2.  Alumina-on-alumina THA in patients with juvenile idiopathic arthritis: a 5-year followup study.

Authors:  Ana Cruz-Pardos; Eduardo García-Rey; Eduardo García-Cimbrelo; Jose Ortega-Chamarro
Journal:  Clin Orthop Relat Res       Date:  2011-08-31       Impact factor: 4.176

3.  Clinical and radiographic results and wear performance in different generations of a cementless porous-coated acetabular cup.

Authors:  E García-Rey; E García-Cimbrelo
Journal:  Int Orthop       Date:  2007-01-31       Impact factor: 3.075

4.  Similar wear in total hip arthroplasties with metallic or zirconia femoral heads.

Authors:  Randy M Cohn; Alejandro González Della Valle; Margaret Peterson; Charles N Cornell
Journal:  HSS J       Date:  2008-07-15

5.  Polyethylene in total hip arthroplasty: half a century in the limelight.

Authors:  Eduardo García-Rey; Eduardo García-Cimbrelo
Journal:  J Orthop Traumatol       Date:  2010-05-27

6.  Alumina-on-alumina total hip arthroplasty in young patients: diagnosis is more important than age.

Authors:  Eduardo Garcia-Rey; Ana Cruz-Pardos; Eduardo Garcia-Cimbrelo
Journal:  Clin Orthop Relat Res       Date:  2009-06-04       Impact factor: 4.176

7.  Clinical comparison of polyethylene wear with zirconia or cobalt-chromium femoral heads.

Authors:  Maiken Stilling; Kjeld Anton Nielsen; Kjeld Søballe; Ole Rahbek
Journal:  Clin Orthop Relat Res       Date:  2009-03-27       Impact factor: 4.176

8.  A randomised prospective evaluation of ceramic-on-ceramic and ceramic-on-highly cross-linked polyethylene bearings in the same patients with primary cementless total hip arthroplasty.

Authors:  Young-Hoo Kim; Jang-Won Park; Sourabh S Kulkarni; Yoon-Hong Kim
Journal:  Int Orthop       Date:  2013-08-03       Impact factor: 3.075

9.  Alumina-on-alumina in THA: a multicenter prospective study.

Authors:  Eduardo Garcia-Cimbrelo; Eduardo Garcia-Rey; Antonio Murcia-Mazón; Agustín Blanco-Pozo; Eduardo Martí
Journal:  Clin Orthop Relat Res       Date:  2008-01-10       Impact factor: 4.176

10.  Outcomes after THA in patients with high hip dislocation after childhood sepsis.

Authors:  Young-Hoo Kim; Hee-Soo Seo; Jun-Shik Kim
Journal:  Clin Orthop Relat Res       Date:  2008-12-06       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.