Literature DB >> 11182707

Assessment of ejection fraction with Tl-201 gated SPECT in myocardial infarction: Precision in a rest-redistribution study and accuracy versus planar angiography.

E Itti1, J Rosso, P Damien, M Auffret, J P Thirion, M Meignan.   

Abstract

BACKGROUND: Viability and left ventricular ejection fraction (LVEF) are essential measures for the assessment of myocardial infarction (MI). These 2 variables may be evaluated simultaneously by means of thallium-201 gated single photon emission computed tomography (SPECT); however, the precision and accuracy of LVEF measurements with this isotope remain controversial, particularly in cases of extended perfusion defects and poor count densities. METHODS AND
RESULTS: Fifty patients with a history of MI underwent a 20-minute rest and a 4-hour redistribution Tl-201 gated SPECT viability protocol, immediately followed by a technetium-99m planar equilibrium radionuclide angiography (ERNA). On gated SPECT images, various count statistics were calculated, and perfusion was automatically quantified by means of CardioMatch, which provided both the size and severity of MI defects. Rest and redistribution LVEFs were determined from gated SPECT with Germano's algorithm, whereas LVEFs were calculated from ERNA using the manufacturer's software. Mean LVEF values calculated with rest gated SPECT, redistribution gated SPECT, and planar ERNA were 30% +/- 13%, 30% +/- 13% and 33% +/- 13%, respectively. Significant differences between repeated gated SPECT LVEFs were not shown by means of the paired t test. Correlation coefficients were high between 20-minute and 4-hour scans (r = 0.89) and between gated SPECT and ERNA (r = 0.88 and r = 0.92 at 20 minutes and 4 hours, respectively). Additionally, close agreement between gated SPECT and ERNA was shown by means of the Bland-Altman plot, despite an underestimation of 3 units. Finally, neither the technical conditions (count density, heart rate, lung uptake, etc) nor the perfusion alteration (size, severity, redistribution) appeared to interfere with the precision and accuracy of gated SPECT LVEF measurement.
CONCLUSION: Tl-201 gated SPECT is a precise method for assessing LVEF within the same patient at 4-hour intervals, even with a substantial count decay, and it gives accurate results compared with planar ERNA, even in the case of large perfusion defects.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11182707     DOI: 10.1067/mnc.2001.109863

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  36 in total

Review 1.  Electrocardiographically gated myocardial perfusion SPECT: technical principles and quality control considerations.

Authors:  S J Cullom; J A Case; T M Bateman
Journal:  J Nucl Cardiol       Date:  1998 Jul-Aug       Impact factor: 5.952

2.  Assessment of myocardial viability by dobutamine echocardiography, positron emission tomography and thallium-201 SPECT: correlation with histopathology in explanted hearts.

Authors:  H Baumgartner; G Porenta; Y K Lau; M Wutte; U Klaar; M Mehrabi; R J Siegel; J Czernin; G Laufer; H Sochor; H Schelbert; M C Fishbein; G Maurer
Journal:  J Am Coll Cardiol       Date:  1998-11-15       Impact factor: 24.094

3.  Automatic registration and alignment on a template of cardiac stress and rest reoriented SPECT images.

Authors:  J Declerck; J Feldmar; M L Goris; F Betting
Journal:  IEEE Trans Med Imaging       Date:  1997-12       Impact factor: 10.048

4.  Significance of late redistribution thallium-201 imaging after rest injection for detection of viable myocardium.

Authors:  I Matsunari; S Fujino; J Taki; J Senma; T Aoyama; T Wakasugi; J Hirai; T Saga; S Yamamoto; N Tonami
Journal:  J Nucl Med       Date:  1997-07       Impact factor: 10.057

5.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

6.  Assessment of regional and global left ventricular function by reinjection T1-201 and rest Tc-99m sestamibi ECG-gated SPECT: comparison with three-dimensional magnetic resonance imaging.

Authors:  E Tadamura; T Kudoh; M Motooka; M Inubushi; S Shirakawa; N Hattori; T Okada; T Matsuda; T Koshiji; K Nishimura; K Matsuda; J Konishi
Journal:  J Am Coll Cardiol       Date:  1999-03-15       Impact factor: 24.094

7.  Gated TI-201 myocardial perfusion SPECT: application of energy window optimization.

Authors:  S S Wadhwa; R Mansberg; D Wilkinson; D Abbati
Journal:  Clin Nucl Med       Date:  1999-07       Impact factor: 7.794

8.  Analysis of aerosol deposition in the healthy human lung.

Authors:  C S Garrard; T R Gerrity; J F Schreiner; D B Yeates
Journal:  Arch Environ Health       Date:  1981 Jul-Aug

9.  Transient left ventricular dysfunction during provocative mental stress in patients with coronary artery disease.

Authors:  P J LaVeau; A Rozanski; D S Krantz; C E Cornell; L Cattanach; B L Zaret; F J Wackers
Journal:  Am Heart J       Date:  1989-07       Impact factor: 4.749

10.  Identification of severe and extensive coronary artery disease by automatic measurement of transient ischemic dilation of the left ventricle in dual-isotope myocardial perfusion SPECT.

Authors:  M Mazzanti; G Germano; H Kiat; P B Kavanagh; E Alexanderson; J D Friedman; R Hachamovitch; K F Van Train; D S Berman
Journal:  J Am Coll Cardiol       Date:  1996-06       Impact factor: 24.094

View more
  10 in total

1.  Comparative value of ECG-gated blood pool SPET and ECG-gated myocardial perfusion SPET in the assessment of global systolic left ventricular function.

Authors:  Doumit Daou; Didier Vilain; Patrice Colin; Rachida Lebtahi; Thierry Fourme; Carlos Coaguila; Abdel Benada; Ilana Idy-Peretti; Michel Slama; Dominique Le Guludec
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-04-04       Impact factor: 9.236

2.  Variability of serial same-day left ventricular ejection fraction using quantitative gated SPECT.

Authors:  Enrique Vallejo; Hugo Chaya; Gerardo Plancarte; Diana Victoria; David Bialostozky
Journal:  J Nucl Cardiol       Date:  2002 Jul-Aug       Impact factor: 5.952

3.  Comparison of contemporaneous left ventricular ejection fraction (LVEF) obtained from planar gated cardiac blood pool scans (GCBPS) and Tl-201 gated myocardial perfusion scans (MPS) using a novel solid state dedicated cardiac camera.

Authors:  Kenneth S K Yap; Martin Cherk; Bruce Van Every; Michael Bailey; Michael J Kelly; Victor Kalff
Journal:  J Nucl Cardiol       Date:  2013-02-27       Impact factor: 5.952

4.  Inter-institution preference-based variability of ejection fraction and volumes using quantitative gated SPECT with 99mTc-tetrofosmin: a multicentre study involving 106 hospitals.

Authors:  Kenichi Nakajima; Tsunehiko Nishimura
Journal:  Eur J Nucl Med Mol Imaging       Date:  2005-09-29       Impact factor: 9.236

5.  Factors affecting accuracy of ventricular volume and ejection fraction measured by gated tl-201 myocardial perfusion single photon emission computed tomography.

Authors:  Moonsun Pai; You-Jung Yang; Ki Chun Im; Il Ki Hong; Sung Cheol Yun; Duk-Hyun Kang; Jae-Kwan Song; Dae Hyuk Moon
Journal:  Int J Cardiovasc Imaging       Date:  2006-05-12       Impact factor: 2.357

6.  Assessment of ejection fraction with Tl-201 gated SPECT in myocardial infarction: Precision in a rest-redistribution study and accuracy versus planar angiography.

Authors:  E Itti; J Rosso; P Damien; M Auffret; J P Thirion; M Meignan
Journal:  J Nucl Cardiol       Date:  2001 Jan-Feb       Impact factor: 5.952

7.  Myocardial perfusion defects with near-to-absent count reduction: a comparison of gated SPECT to radionuclide ventriculography in the determination of left ventricular function.

Authors:  Fevziye Canbaz; Tarik Basoglu; Oktay Yapici; Safak Aygul; Mustafa Yazici
Journal:  Int J Cardiovasc Imaging       Date:  2005-10-27       Impact factor: 2.357

8.  Sex-specific reference limits of left ventricular ejection fraction and volumes estimated by gated myocardial perfusion imaging for low-risk patients in China: a comparison between three quantitative algorithms.

Authors:  Jiajun Li; Lin Guo; Jingzhe Liu; Wei Fang; Xiaoxin Sun; Zuoxiang He
Journal:  Quant Imaging Med Surg       Date:  2022-01

9.  Transient postischemic stunning evaluation by stress gated Tl-201 SPECT myocardial imaging: Effect on systolic left ventricular function.

Authors:  Sherif I Heiba; Jonas Santiago; Majid Mirzaitehrane; Suman Jana; Fuat Dede; Hussein M Abdel-Dayem
Journal:  J Nucl Cardiol       Date:  2002 Sep-Oct       Impact factor: 5.952

10.  Assessment of Left Ventricular Ejection Fraction by Thallium-201 Myocardial SPECT-CT in Patients with Angina Pectoris: Comparison with 2D Echocardiography.

Authors:  Ji Young Kim; Hwan-Cheol Park; Soo Jeong Kim; Hyung Seok Chang; Hyung Jin Choi; Young Hwan Kim
Journal:  Nucl Med Mol Imaging       Date:  2019-01-16
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.