Literature DB >> 16261279

Myocardial perfusion defects with near-to-absent count reduction: a comparison of gated SPECT to radionuclide ventriculography in the determination of left ventricular function.

Fevziye Canbaz1, Tarik Basoglu, Oktay Yapici, Safak Aygul, Mustafa Yazici.   

Abstract

OBJECTIVE: The main aim of the study was, to estimate the impact of perfusion defects including significantly depleted areas of varying size on gated perfusion SPECT (GPS) determined ejection fraction (EF) measurements in comparison to radionuclide ventriculography (RVG). A secondary objective was the evaluation of the GPS-RVG agreement of EF in patients with normal and deteriorated left ventricular function, separately.
METHODS: Fifty-nine patients having perfusion defects including at least one segment with no visible tracer uptake in rest myocardial GPS related to myocardial infarction (older than 15 days) were studied. Myocardial perfusion was visually analyzed using a 17 segment-model, on a five-point (0-4) grading system in which Grade-4 (0-9% maximal uptake) represents cold defects. The patients with >or=4 adjacent, with 2-3 adjacent and with 1 single cold segments were named as Group1(GR1), Group2(GR2) and Group3(GR3), respectively. Secondly, the patients were re-grouped according to RVG-EF values. (Group A: patients with EF<50%; Group B: patients with EF>or=50%). In each group, the GPS-EFs were compared with RVG performed within one week and also the variations of GPS-RVG EF differences among the groups were statistically analyzed.
RESULTS: In overall (r=0.86) and in each subgroup, EFs obtained by GPS were well correlated with RVG. However, in overall (difference mean EF% [dEF%]=4.6+/-6.7, p<0.001) as well as in subgroup evaluation, GPS significantly (p<0.005) underestimated EF. There was no statistically significant difference in GPS-RVG EF variations between GR1, GR2 and GR3 (p>0.05). The RVG-mean differences and RVG-correlation coefficients calculated for GR1,GR2 and GR3 were dEF%=3.1+/-4.6, r=0.85; dEF%=3.7+/-6.03, r=0.80 and dEF%=6.2+/-8.03, r=0.79, respectively. Mean dEF% was statistically higher in group-B than group-A (mean difference of dEF%=4,2, p<0.05). In group-A, GPS-EF values were better agreed with RVG (dEF%=3.34, r=0.75) than in group-B (dEF%=7.52, r=0.53).
CONCLUSION: The stability of the calculation algorithm of QGS in EF calculation of patients with large depleted infarct areas could be confirmed. The agreement of GPS determined EF is higher in patients having myocardial integrity loss and left ventricular dysfunction.

Entities:  

Mesh:

Year:  2005        PMID: 16261279     DOI: 10.1007/s10554-005-9024-0

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  20 in total

1.  Electrocardiogram-gated single-photon emission computed tomography versus cardiac magnetic resonance imaging for the assessment of left ventricular volumes and ejection fraction: a meta-analysis.

Authors:  John P A Ioannidis; Thomas A Trikalinos; Peter G Danias
Journal:  J Am Coll Cardiol       Date:  2002-06-19       Impact factor: 24.094

Review 2.  Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association.

Authors:  Manuel D Cerqueira; Neil J Weissman; Vasken Dilsizian; Alice K Jacobs; Sanjiv Kaul; Waren K Laskey; Dudley J Pennell; John A Rumberger; Thomas Ryan; Mario S Verani
Journal:  Int J Cardiovasc Imaging       Date:  2002-02       Impact factor: 2.357

3.  Assessment of left ventricular volume using ECG-gated SPECT with technetium-99m-MIBI and technetium-99m-tetrofosmin.

Authors:  T Mochizuki; K Murase; H Tanaka; T Kondoh; K Hamamoto; W N Tauxe
Journal:  J Nucl Med       Date:  1997-01       Impact factor: 10.057

4.  Quantification of left ventricular function with thallium-201 and technetium-99m-sestamibi myocardial gated SPECT.

Authors:  C Maunoury; C C Chen; K B Chua; C J Thompson
Journal:  J Nucl Med       Date:  1997-06       Impact factor: 10.057

5.  Clinical validation of automatic quantitative defect size in rest technetium-99m-sestamibi myocardial perfusion SPECT.

Authors:  X Kang; D S Berman; K F Van Train; A M Amanullah; J Areeda; J D Friedman; H Kiat; G Germano
Journal:  J Nucl Med       Date:  1997-09       Impact factor: 10.057

6.  Assessment of left ventricular systolic and diastolic function based on the edge detection method with myocardial ECG-gated SPET.

Authors:  T Higuchi; K Nakajima; J Taki; S Kinuya; H Bunko; N Tonami
Journal:  Eur J Nucl Med       Date:  2001-10

7.  Left ventricular volumes, ejection fraction, and regional wall motion calculated with gated technetium-99m tetrofosmin SPECT in reperfused acute myocardial infarction at super-acute phase: comparison with left ventriculography.

Authors:  M Abe; Y Kazatani; H Fukuda; H Tatsuno; H Habara; H Shinbata
Journal:  J Nucl Cardiol       Date:  2000 Nov-Dec       Impact factor: 5.952

8.  Assessment of ejection fraction with Tl-201 gated SPECT in myocardial infarction: Precision in a rest-redistribution study and accuracy versus planar angiography.

Authors:  E Itti; J Rosso; P Damien; M Auffret; J P Thirion; M Meignan
Journal:  J Nucl Cardiol       Date:  2001 Jan-Feb       Impact factor: 5.952

9.  Evaluation of left ventricular function and volumes in patients with ischaemic cardiomyopathy: gated single-photon emission computed tomography versus two-dimensional echocardiography.

Authors:  E C Vourvouri; D Poldermans; J J Bax; G Sianos; F B Sozzi; A F Schinkel; J de Sutter; G Parcharidis; R Valkema; J R Roelandt
Journal:  Eur J Nucl Med       Date:  2001-11

10.  201Tl and 99mTc-MIBI gated SPECT in patients with large perfusion defects and left ventricular dysfunction: comparison with equilibrium radionuclide angiography.

Authors:  A Manrique; M Faraggi; P Véra; D Vilain; R Lebtahi; A Cribier; D Le Guludec
Journal:  J Nucl Med       Date:  1999-05       Impact factor: 10.057

View more
  2 in total

1.  The impacts of severe perfusion defects, akinetic/dyskinetic segments, and viable myocardium on the accuracy of volumes and LVEF measured by gated ⁹⁹mTc-MIBI SPECT and gated ¹⁸F-FDG PET in patients with left ventricular aneurysm: cardiac magnetic resonance imaging as the reference.

Authors:  Hongxing Wei; Congna Tian; Thomas H Schindler; Mei Qiu; Minjie Lu; Rui Shen; Yueqin Tian; Shi-hua Zhao; Xiaoli Zhang
Journal:  J Nucl Cardiol       Date:  2014-09-05       Impact factor: 5.952

2.  Left ventricular aneurysm in the scope of gated perfusion SPECT: accuracy of detection and ejection fraction calculation.

Authors:  Fevziye Canbaz; Tarik Basoglu; Kenan Durna; Sibel Ucak Semirgin; Sevgi Canbaz
Journal:  Int J Cardiovasc Imaging       Date:  2008-02-16       Impact factor: 2.357

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.