Literature DB >> 12677300

Comparative value of ECG-gated blood pool SPET and ECG-gated myocardial perfusion SPET in the assessment of global systolic left ventricular function.

Doumit Daou1, Didier Vilain, Patrice Colin, Rachida Lebtahi, Thierry Fourme, Carlos Coaguila, Abdel Benada, Ilana Idy-Peretti, Michel Slama, Dominique Le Guludec.   

Abstract

Both electrocardiographically (ECG) gated blood pool SPET (GBPS) and ECG-gated myocardial perfusion SPET (GSPET) are currently used for the measurement of global systolic left ventricular (LV) function. In this study, we aimed to compare the value of GSPET and GBPS for this purpose. The population included 65 patients who underwent rest thallium-201 GSPET imaging at 15 min after (201)Tl injection followed by planar (planar(RNA)) and GBPS equilibrium radionuclide angiography immediately after 4-h redistribution myocardial perfusion SPET imaging. Thirty-five patients also underwent LV conventional contrast angiography (X-rays). LV ejection fraction (EF) and LV volume [end-diastolic (EDV) and end-systolic (ESV) volumes] were calculated with GBPS and GSPET and compared with the gold standard methods (planar(RNA) LVEF and X-ray based calculation of LV volume). For both LVEF and LV volume, the inter-observer variability was lower with GBPS than with GSPET. GBPS LVEF was higher than planar(RNA) (P<0.01) and GSPET LVEF (P<0.01). Planar(RNA) LVEF showed a slightly better correlation with GBPS LVEF than with GSPET LVEF: r=0.87 and r=0.83 respectively. GSPET LV volume was lower than that obtained using X-rays and GBPS (P<0.01 for both). LV volume calculated using X-rays showed a slightly better correlation with GBPS LV volume than with GSPET LV volume: r=0.88 and r=0.83 respectively. On stepwise regression analysis, the accuracy of GSPET for the measurement of LVEF and LV volume was correlated with a number of factors, including planar(RNA) LVEF, signal to noise ratio, LV volume calculated using X-rays, summed rest score and acquisition scan distance (i.e. the radius of rotation). The accuracy of GBPS for the measurement of LVEF and LV volume was correlated only with the signal level, the signal to noise ratio and the acquisition scan distance. Both GSPET and GBPS provide reliable estimation of global systolic LV function. The better reliability of GBPS and in particular its lower sensitivity to different variables as compared with GSPET favours its use when precise assessment of global systolic LV function is clinically indicated.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12677300     DOI: 10.1007/s00259-003-1121-5

Source DB:  PubMed          Journal:  Eur J Nucl Med Mol Imaging        ISSN: 1619-7070            Impact factor:   9.236


  26 in total

1.  Quantitative gated SPECT myocardial perfusion imaging with 201Tl: an assessment of the limitations.

Authors:  G A Wright; M McDade; W Keeble; W Martin; I Hutton
Journal:  Nucl Med Commun       Date:  2000-12       Impact factor: 1.690

2.  Electrocardiographically gated blood-pool SPECT and left ventricular function: comparative value of 3 methods for ejection fraction and volume estimation.

Authors:  D Daou; F Harel; B O Helal; T Fourme; P Colin; R Lebtahi; D Mariano-Goulart; M Faraggi; M Slama; D Le Guludec
Journal:  J Nucl Med       Date:  2001-07       Impact factor: 10.057

3.  Thallium-201 gated single-photon emission tomography for the assessment of left ventricular ejection fraction and regional wall motion abnormalities in comparison with two-dimensional echocardiography.

Authors:  C Bacher-Stier; S Müller; O Pachinger; S Strolz; H Erler; R Moncayo; M Wenger; E Donnemiller; G Riccabona
Journal:  Eur J Nucl Med       Date:  1999-12

4.  A scintiphotographic method for measuring left ventricular ejection fraction in man without cardiac catheterization.

Authors:  H W Strauss; B L Zaret; P J Hurley; T K Natarajan; B Pitt
Journal:  Am J Cardiol       Date:  1971-11       Impact factor: 2.778

5.  Gated myocardial perfusion tomography for the assessment of left ventricular function and volumes: comparison with echocardiography.

Authors:  E Cwajg; J Cwajg; Z X He; W S Hwang; F Keng; S F Nagueh; M S Verani
Journal:  J Nucl Med       Date:  1999-11       Impact factor: 10.057

6.  Normal limits for left ventricular ejection fraction and volumes estimated with gated myocardial perfusion imaging in patients with normal exercise test results: influence of tracer, gender, and acquisition camera.

Authors:  A A Ababneh; R R Sciacca; B Kim; S R Bergmann
Journal:  J Nucl Cardiol       Date:  2000 Nov-Dec       Impact factor: 5.952

7.  Automatic determination of left ventricular ejection fraction from gated blood-pool tomography.

Authors:  C Vanhove; P R Franken; M Defrise; A Momen; H Everaert; A Bossuyt
Journal:  J Nucl Med       Date:  2001-03       Impact factor: 10.057

8.  Accuracy of left ventricular ejection fraction determined by gated myocardial perfusion SPECT with Tl-201 and Tc-99m sestamibi: comparison with first-pass radionuclide angiography.

Authors:  Z X He; E Cwajg; J S Preslar; J J Mahmarian; M S Verani
Journal:  J Nucl Cardiol       Date:  1999 Jul-Aug       Impact factor: 5.952

9.  201Tl and 99mTc-MIBI gated SPECT in patients with large perfusion defects and left ventricular dysfunction: comparison with equilibrium radionuclide angiography.

Authors:  A Manrique; M Faraggi; P Véra; D Vilain; R Lebtahi; A Cribier; D Le Guludec
Journal:  J Nucl Med       Date:  1999-05       Impact factor: 10.057

10.  Comparative study of three automatic programs of left ventricular ejection fraction evaluation.

Authors:  P Véra; I Gardin; B Bok
Journal:  Nucl Med Commun       Date:  1995-08       Impact factor: 1.690

View more
  6 in total

1.  Individual measurements may not closely follow average tendencies: the paradigm of nuclear cardiology.

Authors:  Efstratios Moralidis; Georgios Arsos; Dimitrios Boundas; Konstantinos Karakatsanis
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-09-20       Impact factor: 9.236

Review 2.  SPECT radionuclide angiography: it is time for a consensus statement.

Authors:  Doumit Daou
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-11       Impact factor: 9.236

3.  Comparison of contemporaneous left ventricular ejection fraction (LVEF) obtained from planar gated cardiac blood pool scans (GCBPS) and Tl-201 gated myocardial perfusion scans (MPS) using a novel solid state dedicated cardiac camera.

Authors:  Kenneth S K Yap; Martin Cherk; Bruce Van Every; Michael Bailey; Michael J Kelly; Victor Kalff
Journal:  J Nucl Cardiol       Date:  2013-02-27       Impact factor: 5.952

4.  Gated blood pool SPECT for measurement of left ventricular volumes and left ventricular ejection fraction: comparison of 8 and 16 frame gated blood pool SPECT.

Authors:  Seong-Jang Kim; In-Ju Kim; Yun-Seong Kim; Yong-Ki Kim
Journal:  Int J Cardiovasc Imaging       Date:  2005 Apr-Jun       Impact factor: 2.357

5.  Automatic quantification of right ventricular volumes and right ventricular ejection fraction with gated blood pool SPECT: Comparison of 8- and 16-frame gated blood pool SPECT with first-pass radionuclide angiography.

Authors:  Seong-Jang Kim; In-Ju Kim; Yun-Seong Kim; Yong-Ki Kim; Yong Beom Shin; Dong-Soo Kim
Journal:  J Nucl Cardiol       Date:  2005 Sep-Oct       Impact factor: 5.952

6.  Comparison of radionuclide ventriculography using SPECT and planar techniques in different cardiac conditions.

Authors:  Teresa Massardo; Rodrigo Jaimovich; Hugo Lavados; Daniela Gutiérrez; J Carlos Rodríguez; J Miguel Saavedra; Rita Alay; Héctor Gatica
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-06-20       Impact factor: 10.057

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.