Scatter/primary in mammography: comprehensive results.

J M Boone1, K K Lindfors, V N Cooper, J A Seibert.   

Abstract

Monte Carlo procedures using the SIERRA code (validated in a companion article) were used to investigate the scatter properties in mammography. The scatter to primary ratio (SPR) was used for quantifying scatter levels as a function of beam spectrum, position in the field, air gap, breast thickness, tissue composition, and the area of the field of view (FOV). The geometry of slot scan mammography was also simulated, and SPR values were calculated as a function of slot width. The influence of large air gaps (to 30 cm) was also studied in the context of magnification mammography. X-ray energy and tissue composition from 100% adipose to 100% glandular demonstrated little effect on the SPR. Air gaps over a range from 0 to 30 mm showed only slight effects. The SPR increased with increased breast thickness and with larger fields of view. Measurements from 82 mammograms provided estimates of the range of compressed breast thickness (median: 5.2 cm, 95% range: 2.4 cm to 7.9 cm) and projected breast area onto the film (left craniocaudal view, median: 146 cm2, 95% range: 58 cm2 to 298 cm2). SPR values for semicircular breast shapes, Mo/Mo spectra, and a 15 mm air gap were parametrized as a function of breast thickness and (semicircular) breast diameter. With the coefficients a = - 2.35452817439093, b = 22.3960980055927, and c = 8.85064260299289, the equation SPR= [a + b x (diameter in cm)--(-1.5) + c x (thickness in cm) --(-0.5)]-- -1 produces SPR data from 2 to 8 cm and from 3 to 30 cm breast diameters with an average error of about 1%.

Entities:  

Mesh:

Year:  2000        PMID: 11099211     DOI: 10.1118/1.1312812

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  29 in total

1.  Scatter radiation in digital tomosynthesis of the breast.

Authors:  Ioannis Sechopoulos; Sankararaman Suryanarayanan; Srinivasan Vedantham; Carl J D'Orsi; Andrew Karellas
Journal:  Med Phys       Date:  2007-02       Impact factor: 4.071

2.  Radiation dose to organs and tissues from mammography: Monte Carlo and phantom study.

Authors:  Ioannis Sechopoulos; Sankararaman Suryanarayanan; Srinivasan Vedantham; Carl J D'Orsi; Andrew Karellas
Journal:  Radiology       Date:  2007-12-04       Impact factor: 11.105

3.  Rejection and redistribution of scattered radiation in scan equalization digital radiography (SEDR): simulation with spot images.

Authors:  Xinming Liu; Chris C Shaw
Journal:  Med Phys       Date:  2007-07       Impact factor: 4.071

4.  Monte Carlo and phantom study of the radiation dose to the body from dedicated CT of the breast.

Authors:  Ioannis Sechopoulos; Srinivasan Vedantham; Sankararaman Suryanarayanan; Carl J D'Orsi; Andrew Karellas
Journal:  Radiology       Date:  2008-02-21       Impact factor: 11.105

5.  The effect of scatter and glare on image quality in contrast-enhanced breast imaging using an a-Si/CsI(TI) full-field flat panel detector.

Authors:  Ann-Katherine Carton; Raymond Acciavatti; Johnny Kuo; Andrew D A Maidment
Journal:  Med Phys       Date:  2009-03       Impact factor: 4.071

6.  Comparison of slot scanning digital mammography system with full-field digital mammography system.

Authors:  Chao-Jen Lai; Chris C Shaw; William Geiser; Lingyun Chen; Elsa Arribas; Tanya Stephens; Paul L Davis; Geetha P Ayyar; Basak E Dogan; Victoria A Nguyen; Gary J Whitman; Wei T Yang
Journal:  Med Phys       Date:  2008-06       Impact factor: 4.071

7.  Scatter rejection and low-contrast performance of a slot-scan digital chest radiography system with electronic aft-collimation: a chest phantom study.

Authors:  Xinming Liu; Chris C Shaw; Chao-Jen Lai; Mustafa C Altunbas; Lingyun Chen; Tao Han; Tianpeng Wang
Journal:  Med Phys       Date:  2008-06       Impact factor: 4.071

8.  Evaluation of scatter effects on image quality for breast tomosynthesis.

Authors:  Gang Wu; James G Mainprize; John M Boone; Martin J Yaffe
Journal:  Med Phys       Date:  2009-10       Impact factor: 4.071

9.  A comparative analysis of OTF, NPS, and DQE in energy integrating and photon counting digital x-ray detectors.

Authors:  Raymond J Acciavatti; Andrew D A Maidment
Journal:  Med Phys       Date:  2010-12       Impact factor: 4.071

10.  Characterization of scatter magnitude and distribution in dedicated breast computed tomography with bowtie filters.

Authors:  Kimberly Kontson; Robert J Jennings
Journal:  J Med Imaging (Bellingham)       Date:  2014-12-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.