Literature DB >> 9396869

Dual matrix ordered subsets reconstruction for accelerated 3D scatter compensation in single-photon emission tomography.

C Kamphuis1, F J Beekman, P P van Rijk, M A Viergever.   

Abstract

Three-dimensional (3D) iterative maximum likelihood expectation maximization (ML-EM) algorithms for single-photon emission tomography (SPET) are capable of correcting image-degrading effects of non-uniform attenuation, distance-dependent camera response and patient shape-dependent scatter. However, the resulting improvements in quantitation, resolution and signal-to-noise ratio (SNR) are obtained at the cost of a huge computational burden. This paper presents a new acceleration method for ML-EM: dual matrix ordered subsets (DM-OS). DM-OS combines two acceleration methods: (a) different matrices for projection and back-projection and (b) ordered subsets of projections. DM-OS was compared with ML-EM on simulated data and on physical thorax phantom data, for both 180 degrees and 360 degrees orbits. Contrast, normalized standard deviation and mean squared error were calculated for the digital phantom experiment. DM-OS resulted in similar image quality to ML-EM, even for speed-up factors of 200 compared to ML-EM in the case of 120 projections. The thorax phantom data could be reconstructed 50 times faster (60 projections) using DM-OS with preservation of image quality. ML-EM and DM-OS with scatter compensation showed significant improvement of SNR compared to ML-EM without scatter compensation. Furthermore, inclusion of complex image formation models in the computer code is simplified in the case of DM-OS. It is thus shown that DM-OS is a fast and relatively simple algorithm for 3D iterative scatter compensation, with similar results to conventional ML-EM, for both 180 degrees and 360 degrees acquired data.

Entities:  

Mesh:

Year:  1998        PMID: 9396869     DOI: 10.1007/s002590050188

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  12 in total

1.  Unmatched projector/backprojector pairs in an iterative reconstruction algorithm.

Authors:  G L Zeng; G T Gullberg
Journal:  IEEE Trans Med Imaging       Date:  2000-05       Impact factor: 10.048

Review 2.  Scatter modelling and compensation in emission tomography.

Authors:  Habib Zaidi; Kenneth F Koral
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-03-31       Impact factor: 9.236

3.  Resolution recovery in pinhole SPECT based on multi-ray projections: a phantom study.

Authors:  Christian Vanhove; Andriy Andreyev; Michel Defrise; Johan Nuyts; Axel Bossuyt
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-09-05       Impact factor: 9.236

4.  Development and evaluation of an improved quantitative (90)Y bremsstrahlung SPECT method.

Authors:  Xing Rong; Yong Du; Michael Ljungberg; Erwann Rault; Stefaan Vandenberghe; Eric C Frey
Journal:  Med Phys       Date:  2012-05       Impact factor: 4.071

Review 5.  Quantitative myocardial perfusion SPECT.

Authors:  B M Tsui; E C Frey; K J LaCroix; D S Lalush; W H McCartney; M A King; G T Gullberg
Journal:  J Nucl Cardiol       Date:  1998 Sep-Oct       Impact factor: 5.952

6.  A residual correction method for high-resolution PET reconstruction with application to on-the-fly Monte Carlo based model of positron range.

Authors:  Lin Fu; Jinyi Qi
Journal:  Med Phys       Date:  2010-02       Impact factor: 4.071

7.  Accelerated statistical reconstruction for C-arm cone-beam CT using Nesterov's method.

Authors:  Adam S Wang; J Webster Stayman; Yoshito Otake; Sebastian Vogt; Gerhard Kleinszig; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2015-05       Impact factor: 4.071

8.  Counter examples for unmatched projector/backprojector in an iterative algorithm.

Authors:  Gengsheng L Zeng
Journal:  Chin J Acad Radiol       Date:  2019-04-11

Review 9.  The Use of Anatomical Information for Molecular Image Reconstruction Algorithms: Attenuation/Scatter Correction, Motion Compensation, and Noise Reduction.

Authors:  Se Young Chun
Journal:  Nucl Med Mol Imaging       Date:  2016-02-11

10.  Simultaneous technetium-99m/thallium-201 SPECT imaging with model-based compensation for cross-contaminating effects.

Authors:  D J Kadrmas; E C Frey; B M Tsui
Journal:  Phys Med Biol       Date:  1999-07       Impact factor: 3.609

View more