Literature DB >> 34104875

Counter examples for unmatched projector/backprojector in an iterative algorithm.

Gengsheng L Zeng1,2.   

Abstract

It is rather controversial whether it is justified to use an unmatched projector/backprojector pair in an iterative image reconstruction algorithm. One common concern of using an unmatched projector/backprojector pair is that the optimal solution cannot be reached. This concern is misleading and must be clarified. We define a figure-of-merit in the image domain as the distance between the reconstructed image and the true image, as the normalized mean-squared-error (NMSE). The NMSE is used to determine whether an unmatched matched projector/backprojector pair can provide a better image than a matched projector/backprojector pair. Hot and cold lesion's contrast-to-noise ratio is also used as an alternative secondary figure-of-merit for algorithm comparison. Computer-generated counterexamples are used to test the performance for matched and unmatched projection/backprojection pairs for different reconstruction algorithms. The projectors are ray-driven, and the backprojectors are ray-driven and pixel-driven. For the attenuation-free data examples, the unmatched pixel-driven backprojector outperforms the matched ray-driven backprojector. For the attenuated data example, the matched ray-driven backprojector performs better. The ray-driven backprojector can be slightly improved by using an attenuation coefficient that is larger than the true one; in this case the backprojector becomes unmatched. Unmatched projector/backprojector pairs are fairly flexible. If the backprojector is properly chosen, good results can be obtained. However, we have not found a general rule to select a good backprojector.

Entities:  

Keywords:  Iterative algorithms; Projector/backprojector pair; Tomographic image reconstruction

Year:  2019        PMID: 34104875      PMCID: PMC8184118          DOI: 10.1007/s42058-019-00006-1

Source DB:  PubMed          Journal:  Chin J Acad Radiol        ISSN: 2520-8985


  12 in total

1.  Distance-driven projection and backprojection in three dimensions.

Authors:  Bruno De Man; Samit Basu
Journal:  Phys Med Biol       Date:  2004-06-07       Impact factor: 3.609

2.  Bayesian reconstructions from emission tomography data using a modified EM algorithm.

Authors:  P J Green
Journal:  IEEE Trans Med Imaging       Date:  1990       Impact factor: 10.048

3.  Maximum likelihood reconstruction for emission tomography.

Authors:  L A Shepp; Y Vardi
Journal:  IEEE Trans Med Imaging       Date:  1982       Impact factor: 10.048

4.  System matrix modelling of externally tracked motion.

Authors:  Arman Rahmim; Ju-Chieh Cheng; Katie Dinelle; Mikhail Shilov; W Paul Segars; Olivier G Rousset; Benjamin M W Tsui; Dean F Wong; Vesna Sossi
Journal:  Nucl Med Commun       Date:  2008-06       Impact factor: 1.690

5.  Iterative reconstruction in x-ray computed laminography from differential phase measurements.

Authors:  Sébastien Harasse; Wataru Yashiro; Atsushi Momose
Journal:  Opt Express       Date:  2011-08-15       Impact factor: 3.894

6.  Matched Backprojection Operator for Combined Scanning Transmission Electron Microscopy Tilt- and Focal Series.

Authors:  Tim Dahmen; Holger Kohr; Niels de Jonge; Philipp Slusallek
Journal:  Microsc Microanal       Date:  2015-06-05       Impact factor: 4.127

7.  On Few-View Tomography and Staircase Artifacts.

Authors:  Gengsheng L Zeng
Journal:  IEEE Trans Nucl Sci       Date:  2015-02-23       Impact factor: 1.679

8.  Dual matrix ordered subsets reconstruction for accelerated 3D scatter compensation in single-photon emission tomography.

Authors:  C Kamphuis; F J Beekman; P P van Rijk; M A Viergever
Journal:  Eur J Nucl Med       Date:  1998-01

9.  An Effective CUDA Parallelization of Projection in Iterative Tomography Reconstruction.

Authors:  Lizhe Xie; Yining Hu; Bin Yan; Lin Wang; Benqiang Yang; Wenyuan Liu; Libo Zhang; Limin Luo; Huazhong Shu; Yang Chen
Journal:  PLoS One       Date:  2015-11-30       Impact factor: 3.240

10.  Monte Carlo-based quantitative pinhole SPECT reconstruction using a ray-tracing back-projector.

Authors:  Mikael Peterson; Johan Gustafsson; Michael Ljungberg
Journal:  EJNMMI Phys       Date:  2017-12-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.