Literature DB >> 10973470

Semiautomated quantification of hepatitis B virus DNA in a routine diagnostic laboratory.

H H Kessler1, E Stelzl, E Daghofer, B I Santner, E Marth, H Lackner, R E Stauber.   

Abstract

The Cobas Amplicor HBV Monitor test for quantitative determination of hepatitis B virus (HBV) DNA in serum has recently been introduced. To evaluate the performance of this assay in a routine diagnostic laboratory, reproducibility of results was determined with the First European Union Concerted Action HBV Proficiency Panel and the Accurun 325 HBV DNA Positive Control, Series 300. Results for 270 routine serum samples were additionally evaluated. To avoid the retesting of a large number of samples due to titers exceeding the upper limit for the linear range of the assay, sera of patients with chronic hepatitis B (CHB) were diluted prior to the assay to 10(-4) in normal human plasma, which is included in the assay. The mean coefficient of variation was 22.9% for all input HBV DNAs. Of 270 routine serum samples, 182 (150 sera from transplant donors and 32 sera from patients who had recovered from CHB) tested negative. Eighty-six sera were found to be HBV DNA positive; in six sera, HBV DNA levels were found to exceed the upper limit for the linear range of the assay and had to be retested. In the remaining two sera, inhibition occurred. The semiautomated Cobas Amplicor HBV Monitor test showed sufficient reproducibility and helped in avoiding human error. The relatively narrow linear range of detection is a limitation of the new assay.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10973470      PMCID: PMC95971          DOI: 10.1128/CDLI.7.5.853-855.2000

Source DB:  PubMed          Journal:  Clin Diagn Lab Immunol        ISSN: 1071-412X


  15 in total

1.  Evaluation of the COBAS AMPLICOR CMV MONITOR test for detection of viral DNA in specimens taken from patients after liver transplantation.

Authors:  I G Sia; J A Wilson; M J Espy; C V Paya; T F Smith
Journal:  J Clin Microbiol       Date:  2000-02       Impact factor: 5.948

2.  Heat-soaked PCR: an efficient method for DNA amplification with applications to forensic analysis.

Authors:  G Ruano; E M Pagliaro; T R Schwartz; K Lamy; D Messina; R E Gaensslen; H C Lee
Journal:  Biotechniques       Date:  1992-08       Impact factor: 1.993

3.  Evaluation of the COBAS AMPLICOR MTB system.

Authors:  T Bodmer; A Gurtner; M Scholkmann; L Matter
Journal:  J Clin Microbiol       Date:  1997-06       Impact factor: 5.948

4.  Evaluation of automated COBAS AMPLICOR PCR system for detection of several infectious agents and its impact on laboratory management.

Authors:  D Jungkind; S Direnzo; K G Beavis; N S Silverman
Journal:  J Clin Microbiol       Date:  1996-11       Impact factor: 5.948

5.  A distinctive property of Tth DNA polymerase: enzymatic amplification in the presence of phenol.

Authors:  H L Katcher; I Schwartz
Journal:  Biotechniques       Date:  1994-01       Impact factor: 1.993

6.  Automated quantitative analysis of hepatitis B virus DNA by using the Cobas Amplicor HBV monitor test.

Authors:  U Noborg; A Gusdal; E K Pisa; A Hedrum; M Lindh
Journal:  J Clin Microbiol       Date:  1999-09       Impact factor: 5.948

7.  Performance of the automated COBAS AMPLICOR system for the detection of hepatitis C virus RNA.

Authors:  H H Kessler; E A Dragon; K Pierer; B I Santner; Y Liao; D Stünzner; E Stelzl; E Marth
Journal:  Clin Diagn Virol       Date:  1997-02

8.  Routine detection and quantification of hepatitis B virus DNA in clinical laboratories: performance of three commercial assays.

Authors:  J M Pawlotsky; A Bastie; C Hézode; I Lonjon; F Darthuy; J Rémiré; D Dhumeaux
Journal:  J Virol Methods       Date:  2000-03       Impact factor: 2.014

9.  Inhibition of human immunodeficiency virus gene amplification by heparin.

Authors:  M Holodniy; S Kim; D Katzenstein; M Konrad; E Groves; T C Merigan
Journal:  J Clin Microbiol       Date:  1991-04       Impact factor: 5.948

10.  Comparison of methods for detection of hepatitis B virus DNA.

Authors:  H L Zaaijer; F ter Borg; H T Cuypers; M C Hermus; P N Lelie
Journal:  J Clin Microbiol       Date:  1994-09       Impact factor: 5.948

View more
  6 in total

1.  Evaluation of the COBAS TaqMan 48 real-time PCR system for quantitation of hepatitis B virus DNA.

Authors:  Rafael M Gordillo; Juan Gutiérrez; Manuel Casal
Journal:  J Clin Microbiol       Date:  2005-07       Impact factor: 5.948

2.  Estimation of smooth ROC curves for biomarkers with limits of detection.

Authors:  Leonidas E Bantis; Qingxiang Yan; John V Tsimikas; Ziding Feng
Journal:  Stat Med       Date:  2017-08-07       Impact factor: 2.373

3.  Evaluation of the COBAS amplicor HBV monitor assay and comparison with the ultrasensitive HBV hybrid capture 2 assay for quantification of hepatitis B virus DNA.

Authors:  Eric Q Konnick; Maria Erali; Edward R Ashwood; David R Hillyard
Journal:  J Clin Microbiol       Date:  2005-02       Impact factor: 5.948

4.  Fully automated, internally controlled quantification of hepatitis B Virus DNA by real-time PCR by use of the MagNA Pure LC and LightCycler instruments.

Authors:  Victoria Leb; Markus Stöcher; Elizabeth Valentine-Thon; Gabriele Hölzl; Harald Kessler; Herbert Stekel; Jörg Berg
Journal:  J Clin Microbiol       Date:  2004-02       Impact factor: 5.948

5.  Rapid quantification of hepatitis B virus DNA by automated sample preparation and real-time PCR.

Authors:  Evelyn Stelzl; Zsofia Muller; Egon Marth; Harald H Kessler
Journal:  J Clin Microbiol       Date:  2004-06       Impact factor: 5.948

6.  [Dual infection with hepatitis B and C. Spontaneous course and response to virostatic therapy in children following neoplastic diseases].

Authors:  Andrea Moser; Herwig Lackner; Johann Deutsch; Reinhold Kerbl; Wolfgang Schwinger; Hans Jürgen Dornbusch; Harald H Kessler; Christian Urban
Journal:  Wien Klin Wochenschr       Date:  2003-01-31       Impact factor: 1.704

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.