Literature DB >> 10931561

Review of patient safety in time-varying gradient fields.

D J Schaefer1, J D Bourland, J A Nyenhuis.   

Abstract

In magnetic resonance, time-varying gradient magnetic fields (dB/dt) may stimulate nerves or muscles by inducing electric fields in patients. Models predicted mean peripheral nerve and cardiac stimulation thresholds. For gradient ramp durations of less than a few milliseconds, mean peripheral nerve stimulation is a safe indicator of high dB/dt. At sufficient amplitudes, peripheral nerve stimulation is perceptible (i.e., tingling or tapping sensations). Magnetic fields from simultaneous gradient axes combine almost as a vector sum to produce stimulation. Patients may become uncomfortable at amplitudes 50%-100% above perception thresholds. In dogs, respiratory stimulation has been induced at about 300% of mean peripheral nerve thresholds. Cardiac stimulation has been induced in dogs by small gradient coils at thresholds near Reilly's predictions. Cardiac stimulation required nearly 80 times the energy needed to produce nerve stimulation in dogs. Nerve and cardiac stimulation thresholds for dogs were unaffected by 1.5-T magnetic fields.

Entities:  

Mesh:

Year:  2000        PMID: 10931561     DOI: 10.1002/1522-2586(200007)12:1<20::aid-jmri3>3.0.co;2-y

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  45 in total

1.  Quantification of adverse events associated with functional MRI scanning and with real-time fMRI-based training.

Authors:  Jon E Hawkinson; Amy J Ross; Sudharshan Parthasarathy; David J Scott; Ella A Laramee; Lainie J Posecion; William R Rekshan; Kristen E Sheau; Nkechi D Njaka; Peter J Bayley; R Christopher deCharms
Journal:  Int J Behav Med       Date:  2012-09

Review 2.  Occupational exposure in MRI.

Authors:  D W McRobbie
Journal:  Br J Radiol       Date:  2012-04       Impact factor: 3.039

3.  Adaptive removal of gradients-induced artefacts on ECG in MRI: a performance analysis of RLS filtering.

Authors:  Mario Sansone; Luciano Mirarchi; Marcello Bracale
Journal:  Med Biol Eng Comput       Date:  2010-03-18       Impact factor: 2.602

Review 4.  [Physical interactions in MRI: Some rules of thumb for their reduction].

Authors:  M Mühlenweg; G Schaefers; S Trattnig
Journal:  Radiologe       Date:  2015-08       Impact factor: 0.635

Review 5.  [Safety aspects in high-field magnetic resonance imaging].

Authors:  M Mühlenweg; G Schaefers; S Trattnig
Journal:  Radiologe       Date:  2008-03       Impact factor: 0.635

Review 6.  Magnetic resonance imaging methodology.

Authors:  Ewald Moser; Andreas Stadlbauer; Christian Windischberger; Harald H Quick; Mark E Ladd
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-03       Impact factor: 9.236

7.  Increasing the oscillation frequency of strong magnetic fields above 101 kHz significantly raises peripheral nerve excitation thresholds.

Authors:  Irving N Weinberg; Pavel Y Stepanov; Stanley T Fricke; Roland Probst; Mario Urdaneta; Daniel Warnow; Howard Sanders; Steven C Glidden; Alan McMillan; Piotr M Starewicz; J Patrick Reilly
Journal:  Med Phys       Date:  2012-05       Impact factor: 4.071

Review 8.  Implementation of a comprehensive MR safety course for medical students.

Authors:  Steffen Sammet; Christina L Sammet
Journal:  J Magn Reson Imaging       Date:  2015-07-14       Impact factor: 4.813

Review 9.  Is MRI imaging in pediatric age totally safe? A critical reprisal.

Authors:  Sergio Salerno; Claudio Granata; Marco Trapenese; Vittorio Cannata; Davide Curione; Maria Camilla Rossi Espagnet; Andrea Magistrelli; Paolo Tomà
Journal:  Radiol Med       Date:  2018-05-03       Impact factor: 3.469

10.  Controlled E-field gradient coils.

Authors:  P Mansfield; R M Bowley; B Haywood
Journal:  MAGMA       Date:  2003-10-31       Impact factor: 2.310