Literature DB >> 14593514

Controlled E-field gradient coils.

P Mansfield1, R M Bowley, B Haywood.   

Abstract

Peripheral neural stimulation is a major problem in current gradient coil designs. Induced current problems in patients relate directly to gradient strength and modulation frequency. Current designs of gradient coil tend to limit ultra-high-speed imaging methods such as echo-planar imaging through the effect of induced currents which produce tingling sensations and involuntary muscle twitch. Neural stimulation could also trigger epileptic fits and/or cardiac fibrillation. For reduction of induced currents, an important aspect is the coil geometry. It is desirable to design the gradient coil in such a way as to prevent closed loop circulating currents within the body. Preliminary results using a four-sector gradient coil with rectangular geometry, operating in a low mutual coupling mode, indicate significant reduction in the E-field within the subject volume of the coil. Reduction in induced currents in the patient allows safer operation at higher magnetic field strengths together with faster scans currently prohibited through neural stimulation effects in standard coil geometries.

Entities:  

Mesh:

Year:  2003        PMID: 14593514     DOI: 10.1007/s10334-003-0015-7

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  13 in total

1.  Simple linear formulation for magnetostimulation specific to MRI gradient coils.

Authors:  B A Chronik; B K Rutt
Journal:  Magn Reson Med       Date:  2001-05       Impact factor: 4.668

2.  Modular gradient coil: A new concept in high-performance whole-body gradient coil design.

Authors:  P R Harvey; E Katznelson
Journal:  Magn Reson Med       Date:  1999-09       Impact factor: 4.668

3.  Analytic calculations of the E-fields induced by time-varying magnetic fields generated by cylindrical gradient coils.

Authors:  R Bowtell; R M Bowley
Journal:  Magn Reson Med       Date:  2000-11       Impact factor: 4.668

4.  Gradient system providing continuously variable field characteristics.

Authors:  Ralph Kimmlingen; Matthias Gebhardt; Johann Schuster; Martin Brand; Franz Schmitt; Axel Haase
Journal:  Magn Reson Med       Date:  2002-04       Impact factor: 4.668

Review 5.  Review of patient safety in time-varying gradient fields.

Authors:  D J Schaefer; J D Bourland; J A Nyenhuis
Journal:  J Magn Reson Imaging       Date:  2000-07       Impact factor: 4.813

Review 6.  Theoretical evaluation of peripheral nerve stimulation during MRI with an implanted spinal fusion stimulator.

Authors:  J P Reilly; A M Diamant
Journal:  Magn Reson Imaging       Date:  1997       Impact factor: 2.546

7.  Magnetization transfer short inversion time inversion recovery enhanced 1H MRI of the human lung.

Authors:  Peter M Jakob; Tungte Wang; Georg Schultz; Helge Hebestreit; Alexandra Hebestreit; Marco Elfeber; Dietbert Hahn; Axel Haase
Journal:  MAGMA       Date:  2002-11       Impact factor: 2.310

8.  Peripheral nerve stimulation during MRI: effects of high gradient amplitudes and switching rates.

Authors:  C L Ham; J M Engels; G T van de Wiel; A Machielsen
Journal:  J Magn Reson Imaging       Date:  1997 Sep-Oct       Impact factor: 4.813

9.  Revised guidance on acceptable limits of exposure during nuclear magnetic resonance clinical imaging.

Authors: 
Journal:  Br J Radiol       Date:  1983-12       Impact factor: 3.039

Review 10.  The AAPM/RSNA physics tutorial for residents. MR imaging safety considerations. Radiological Society of North America.

Authors:  R R Price
Journal:  Radiographics       Date:  1999 Nov-Dec       Impact factor: 5.333

View more
  4 in total

1.  Performance of cryogenic probes as a function of ionic strength and sample tube geometry.

Authors:  Markus W Voehler; Galen Collier; John K Young; Michael P Stone; Markus W Germann
Journal:  J Magn Reson       Date:  2006-09-01       Impact factor: 2.229

2.  Electric field calculation and peripheral nerve stimulation prediction for head and body gradient coils.

Authors:  Peter B Roemer; Trevor Wade; Andrew Alejski; Charles A McKenzie; Brian K Rutt
Journal:  Magn Reson Med       Date:  2021-06-03       Impact factor: 3.737

3.  Early experience of pre- and post-contrast 7.0T MRI in brain tumors.

Authors:  Seung Leal Paek; Young Seob Chung; Sun Ha Paek; Jae Ha Hwang; Chul-Ho Sohn; Seung Hong Choi; Young Don Son; Young Bo Kim; Dong Gyu Kim; Kendall H Lee; Zang-Hee Cho
Journal:  J Korean Med Sci       Date:  2013-08-28       Impact factor: 2.153

4.  Minimum electric-field gradient coil design: Theoretical limits and practical guidelines.

Authors:  Peter B Roemer; Brian K Rutt
Journal:  Magn Reson Med       Date:  2021-02-09       Impact factor: 4.668

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.