Literature DB >> 10884747

Correlation of patient skin doses in cardiac interventional radiology with dose-area product.

S van de Putte1, F Verhaegen, Y Taeymans, H Thierens.   

Abstract

The use of X-rays in cardiac interventional radiology has the potential to induce deterministic radiation effects on the patient's skin. Guidelines published by official organizations encourage the recording of information to evaluate this risk, and the use of reference values in terms of the dose-area product (DAP). Skin dose measurements were made with thermoluminescent dosemeters placed at eight different locations on the body. In addition, DAP was recorded in 100 patients for four types of interventional radiology procedures. Mean, median and third quartile for these results are presented. Maximum skin dose values found were 412 mGy, 725 mGy, 760 mGy and 1800 mGy for coronary catheterization, coronary catheterization with left ventricle investigation, and percutaneous transluminal angiography without and with stenting, respectively. Median DAPs for these same procedures were, respectively, 5682 cGy cm2, 10,632 cGy cm2, 10,880 cGy cm2 and 13,161 cGy cm2. The relationship between DAP and skin dose was investigated. We found a poor correlation of DAP with maximum skin dose (r = 0.77) and skin dose indicator (r = 0.78). Using conversion factors derived from Monte Carlo simulations, skin dose distributions were calculated based on the measured DAPs. Agreement between the calculated skin dose distribution, using DAP values averaged over a group of patients who underwent coronary catheterization and left ventricle investigation, and the measured skin dose averaged over the same group of patients was very good. However, there were large differences between the calculated skin doses using the individual DAP data per patient and measured skin doses for individual patients (r = 0.66). Hence, calculation of individual skin doses based on the specific DAP data per patient is not reliable and therefore measuring skin dose is preferable.

Entities:  

Mesh:

Year:  2000        PMID: 10884747     DOI: 10.1259/bjr.73.869.10884747

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  21 in total

1.  Main clinical, therapeutic and technical factors related to patient's maximum skin dose in interventional cardiology procedures.

Authors:  N Journy; S Sinno-Tellier; C Maccia; A Le Tertre; P Pirard; P Pagès; D Eilstein; J Donadieu; O Bar
Journal:  Br J Radiol       Date:  2012-04       Impact factor: 3.039

2.  Do flat detector cardiac X-ray systems convey advantages over image-intensifier-based systems? Study comparing X-ray dose and image quality.

Authors:  Andrew G Davies; Arnold R Cowen; Stephen M Kengyelics; Janet Moore; Mohan U Sivananthan
Journal:  Eur Radiol       Date:  2006-11-18       Impact factor: 5.315

3.  How to set up and apply reference levels in fluoroscopy at a national level.

Authors:  A Aroua; H Rickli; J-C Stauffer; P Schnyder; P R Trueb; J-F Valley; P Vock; F R Verdun
Journal:  Eur Radiol       Date:  2006-10-27       Impact factor: 5.315

4.  Radiation exposure benefit of a lead cap in invasive cardiology.

Authors:  E Kuon; J Birkel; M Schmitt; J B Dahm
Journal:  Heart       Date:  2003-10       Impact factor: 5.994

5.  Radiation-reducing planning of cardiac catheterisation.

Authors:  E Kuon; J B Dahm; D M Robinson; K Empen; M Günther; W Wucherer
Journal:  Z Kardiol       Date:  2005-10

6.  Development of Diagnostic Reference Levels Using a Real-Time Radiation Dose Monitoring System at a Cardiovascular Center in Korea.

Authors:  Jungsu Kim; Deoknam Seo; Inseok Choi; Sora Nam; Yongsu Yoon; Hyunji Kim; Jae Her; Seonggyu Han; Soonmu Kwon; Hunsik Park; Dongheon Yang; Jungmin Kim
Journal:  J Digit Imaging       Date:  2015-12       Impact factor: 4.056

7.  Radiation peak skin dose to risk stratify electrophysiological procedures for deterministic skin damage.

Authors:  J R Paisey; A M Yue; A White; A Moss; J M Morgan; P R Roberts
Journal:  Int J Cardiovasc Imaging       Date:  2004-08       Impact factor: 2.357

8.  Entrance skin dose measured with MOSFETs in children undergoing interventional radiology procedures.

Authors:  Diana Glennie; Bairbre L Connolly; Christopher Gordon
Journal:  Pediatr Radiol       Date:  2008-08-19

9.  Evaluation of patient-absorbed doses during coronary angiography and intervention by femoral and radial artery access.

Authors:  Michael Sandborg; Sven-Göran Fransson; Håkan Pettersson
Journal:  Eur Radiol       Date:  2003-11-14       Impact factor: 5.315

10.  Patient radiation doses in interventional cardiology procedures.

Authors:  Ioannis Pantos; Georgios Patatoukas; Demosthenes G Katritsis; Efstathios Efstathopoulos
Journal:  Curr Cardiol Rev       Date:  2009-01
View more