Literature DB >> 17115166

Do flat detector cardiac X-ray systems convey advantages over image-intensifier-based systems? Study comparing X-ray dose and image quality.

Andrew G Davies1, Arnold R Cowen, Stephen M Kengyelics, Janet Moore, Mohan U Sivananthan.   

Abstract

The recent introduction of "flat-panel detector" (FD)-based cardiac catheterisation laboratories should offer improvements in image quality and/or dose efficiency over X-ray systems of conventional design. We compared three X-ray systems, one image-intensifier (II)-based system (system A), and two FD-based designs (systems B and C), assessing their image quality and dose efficiency. Phantom measurements were performed to assess dose rates in fluoroscopy and cine acquisition. Phantom dose rates were broadly similar for all systems, with all systems classified as offering "low" dose rates in fluoroscopy on standard phantoms. Patient X-ray dose rate and subjective image quality was assessed for 90 patients. Dose area product (DAP) rates were similar for all systems, except system C, which had a lower DAP rate in fluoroscopy. In terms of subjective image quality, the order of preference was (best to worst): system C, system A, system B. This study indicates that the use of an FD detector does not infer an automatic improvement in image quality or dose efficiency over II based designs. Specification and configuration of all of the components in the X-ray system contribute to the dose levels used and image quality achieved.

Entities:  

Mesh:

Year:  2006        PMID: 17115166     DOI: 10.1007/s00330-006-0458-0

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  15 in total

Review 1.  Fluoroscopy: recording of fluoroscopic images and automatic exposure control.

Authors:  R A Geise
Journal:  Radiographics       Date:  2001 Jan-Feb       Impact factor: 5.333

Review 2.  The AAPM/RSNA physics tutorial for residents: X-ray image intensifiers for fluoroscopy.

Authors:  J Wang; T J Blackburn
Journal:  Radiographics       Date:  2000 Sep-Oct       Impact factor: 5.333

3.  Fluoroscopic image quality in the film and filmless eras: a standardized comparison performed in coronary interventional facilities.

Authors:  Warren Laskey; Merrill Wondrow; Charles Chambers
Journal:  Catheter Cardiovasc Interv       Date:  2003-03       Impact factor: 2.692

4.  Protocol for measurement of patient entrance surface dose rates for fluoroscopic X-ray equipment.

Authors:  C J Martin; D G Sutton; A Workman; A J Shaw; D Temperton
Journal:  Br J Radiol       Date:  1998-12       Impact factor: 3.039

5.  Flat detectors and their clinical applications.

Authors:  Martin Spahn
Journal:  Eur Radiol       Date:  2005-04-02       Impact factor: 5.315

6.  Flat-panel detectors in the cardiac catheterization laboratory: revolution or evolution-what are the issues?

Authors:  David R Holmes; Warren K Laskey; Merrill A Wondrow; Jack T Cusma
Journal:  Catheter Cardiovasc Interv       Date:  2004-11       Impact factor: 2.692

7.  Does digital acquisition reduce patients' skin dose in cardiac interventional procedures? An experimental study.

Authors:  Koichi Chida; Haruo Saito; Masayuki Zuguchi; Kazutoshi Shirotori; Shinsaku Kumagai; Hiromi Nakayama; Kana Matsubara; Masahiro Kohzuki
Journal:  AJR Am J Roentgenol       Date:  2004-10       Impact factor: 3.959

8.  Dose performance evaluation of a charge coupled device and a flat-panel digital fluoroscopy system recently installed in an interventional cardiology laboratory.

Authors:  Virginia Tsapaki; Sophia Kottou; Nikolaos Kollaros; Paraskevi Dafnomili; Zinon Kyriakidis; Vassiliki Neofotistou
Journal:  Radiat Prot Dosimetry       Date:  2004-07-20       Impact factor: 0.972

9.  Comparison of a conventional and a flat-panel digital system in interventional cardiology procedures.

Authors:  V Tsapaki; S Kottou; N Kollaros; P Dafnomili; M Koutelou; E Vano; V Neofotistou
Journal:  Br J Radiol       Date:  2004-07       Impact factor: 3.039

10.  Effective techniques for reduction of radiation dosage to patients undergoing invasive cardiac procedures.

Authors:  E Kuon; C Glaser; J B Dahm
Journal:  Br J Radiol       Date:  2003-06       Impact factor: 3.039

View more
  2 in total

Review 1.  Methods for the analysis of ordinal response data in medical image quality assessment.

Authors:  Claire Keeble; Paul D Baxter; Amber J Gislason-Lee; Laura A Treadgold; Andrew G Davies
Journal:  Br J Radiol       Date:  2016-04-12       Impact factor: 3.039

Review 2.  Coronary imaging techniques with emphasis on CT and MRI.

Authors:  Mathieu Lederlin; Jean-Benoit Thambo; Valérie Latrabe; Olivier Corneloup; Hubert Cochet; Michel Montaudon; François Laurent
Journal:  Pediatr Radiol       Date:  2011-11-30
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.