Improved accuracy and extended flow range for a Fleisch pneumotachograph.

N O Strömberg1, M J Grönkvist.   

Abstract

A large linear flow range and a small instrumental dead space volume are incompatible properties for a pneumotachometer (PTM). The linearity of a Fleisch number 2 PTM is studied for flows up to 6 litre s-1 (nominal range 0-2 litre s-1) with various up- and downstream geometries. It is hypothesised that using an array of calibration factors (conductance; flow/pressure), instead of a single calibration factor over the entire flow range, could improve accuracy and also extend the applicable flow range. The conductance against pressure characteristics are calculated with a previously described weighted averaging technique based on multiple strokes from a precision syringe. A single conductance value gives stroke volume errors in the range of -5 to 3% (0-2 litre s-1) and -6 to 11% (0-6 litre s-1) for validation using the same geometry as for calibration. The pressure dependent conductance improves accuracy to within -3% and 1% independent of flow range. However, for validation using a different geometry than for calibration, errors range from -5% to +8%. The degree of non-linearity varies between the geometries (range 3-15%) and is highest when using a one-directional valve upstream of the PTM and a Y-shaped connector. In conclusion, a pressure-dependent conductance improves accuracy and can also be used to extend the applicable flow range up to at least three times the nominal flow range.

Entities:  

Mesh:

Year:  1999        PMID: 10696702     DOI: 10.1007/bf02513330

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  7 in total

1.  Design and calibration of unicapillary pneumotachographs.

Authors:  A Giannella-Neto; C Bellido; R B Barbosa; M F Melo
Journal:  J Appl Physiol (1985)       Date:  1998-01

2.  Heated Fleisch pneumotachometer: a calibration procedure.

Authors:  S Z Turney; W Blumenfeld
Journal:  J Appl Physiol       Date:  1973-01       Impact factor: 3.531

3.  Linearity and temperature control of the Fleisch pneumotachograph.

Authors:  M R Miller; A C Pincock
Journal:  J Appl Physiol (1985)       Date:  1986-02

4.  The accuracy of pneumotachograph measurements during mechanical ventilation.

Authors:  J W Kreit; F C Sciurba
Journal:  Am J Respir Crit Care Med       Date:  1996-10       Impact factor: 21.405

5.  Linearity and frequency response of pneumotachographs.

Authors:  K E Finucane; B A Egan; S V Dawson
Journal:  J Appl Physiol       Date:  1972-01       Impact factor: 3.531

6.  Computerized determination of pneumotachometer characteristics using a calibrated syringe.

Authors:  M P Yeh; R M Gardner; T D Adams; F G Yanowitz
Journal:  J Appl Physiol Respir Environ Exerc Physiol       Date:  1982-07

7.  Linearity and frequency response of Fleisch type pneumotachometers.

Authors:  J P Zock
Journal:  Pflugers Arch       Date:  1981-10       Impact factor: 3.657

  7 in total
  5 in total

1.  Error analysis of a natural breathing calibration method for respiratory inductive plethysmography.

Authors:  N O Strömberg
Journal:  Med Biol Eng Comput       Date:  2001-05       Impact factor: 2.602

2.  Influence of tidal volume and thoraco-abdominal separation on the respiratory induced variation of the photoplethysmogram.

Authors:  A Johansson; T Strömberg
Journal:  J Clin Monit Comput       Date:  2000       Impact factor: 2.502

3.  Validation of Respiratory Inductance Plethysmography for Measuring Tidal Volume in Swine.

Authors:  Zhenbo Su; Jun Oto; Jingwen Wang; William R Kimball; Christopher T Chenelle; Robert M Kacmarek; David R King; Yandong Jiang; Michael J Duggan
Journal:  Comp Med       Date:  2015-06       Impact factor: 0.982

4.  The syringe potentiometer: a low-cost device for pneumotachograph calibration.

Authors:  Troy J Cross; Eli F Kelley; Tim A Hardy; Jennifer M J Isautier; Bruce D Johnson
Journal:  J Appl Physiol (1985)       Date:  2019-09-05

5.  Comparison of a micro-electro-mechanical system airflow sensor with the pneumotach in the forced oscillation technique.

Authors:  Xiaohe K Xu; Brian P Harvey; Kenneth R Lutchen; Brian D Gelbman; Stephen L Monfre; Robert E Coifman; Charles E Forbes
Journal:  Med Devices (Auckl)       Date:  2018-12-13
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.