Influence of tidal volume and thoraco-abdominal separation on the respiratory induced variation of the photoplethysmogram.

A Johansson1, T Strömberg.   

Abstract

OBJECTIVE: The present study was aimed at determining the relative influences of tidal volume and thoraco-abdominal separation (relative thoracic and abdominal contribution to the tidal volume) on the respiratory induced intensity variation (RIIV) of the photoplethysmographic signal. The effects were studied in two body positions.
METHODS: Respiratory inductive plethysmography was used for quantifying thoraco-abdominal separation and for assessing tidal volumes. 10 subjects were trained to perform widely varying degrees of thoraco-abdominal separation at different tidal volumes. The relationship between the RIIV signal peak-to-peak value (measured at the forearm), and the tidal volume and thoraco-abdominal separation was investigated in two body positions with the use of multiple linear regression.
RESULTS: Larger tidal volume and more thoracic contribution to respiration were found to increase the RIIV peak-to-peak value (p < 0.0005). In the supine position, the tidal volume influence was stronger than that of thoraco-abdominal separation, and in the sitting position, the opposite was seen.
CONCLUSIONS: The effects on the RIIV signal following changes in thoraco-abdominal separation and tidal volume are of the same order of magnitude. In the supine position, the influence of thoracic versus abdominal contribution to the tidal volume is not as significant as in the sitting position. Photoplethysmography is a promising technique for combined monitoring of several respiratory parameters, including tidal volume. In situations where the relative thoracic and abdominal contributions are likely to vary, the tidal volume information becomes less reliable.

Mesh:

Year:  2000        PMID: 12580233     DOI: 10.1023/a:1012260415191

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  16 in total

Review 1.  Pulse oximetry.

Authors:  K K Tremper; S J Barker
Journal:  Anesthesiology       Date:  1989-01       Impact factor: 7.892

2.  Superior and inferior vena caval flows during respiration: pathogenesis of Kussmaul's sign.

Authors:  M Takata; S Beloucif; M Shimada; J L Robotham
Journal:  Am J Physiol       Date:  1992-03

3.  Breathing pattern variability during bronchial histamine and methacholine challenges in asthmatics.

Authors:  N O Strömberg; P M Gustafsson
Journal:  Respir Med       Date:  1996-05       Impact factor: 3.415

4.  The peripheral pulse wave: information overlooked.

Authors:  W B Murray; P A Foster
Journal:  J Clin Monit       Date:  1996-09

5.  Evaluation of various models for respiratory inductance plethysmography calibration.

Authors:  N O Strömberg; G O Dahlbäck; P M Gustafsson
Journal:  J Appl Physiol (1985)       Date:  1993-03

6.  The respiratory inductive plethysmograph: a new non-invasive monitor of respiration.

Authors:  M A Cohn; A S Rao; M Broudy; S Birch; H Watson; N Atkins; B Davis; F D Stott; M A Sackner
Journal:  Bull Eur Physiopathol Respir       Date:  1982 Jul-Aug

7.  A method for clinical evaluation of peripheral circulation: photoelectric hemodensitometry.

Authors:  S Eldrup-Jorgensen; S I Schwartz; J D Wallace
Journal:  Surgery       Date:  1966-04       Impact factor: 3.982

8.  Improved accuracy and extended flow range for a Fleisch pneumotachograph.

Authors:  N O Strömberg; M J Grönkvist
Journal:  Med Biol Eng Comput       Date:  1999-07       Impact factor: 2.602

9.  Monitoring of heart and respiratory rates in newborn infants using a new photoplethysmographic technique.

Authors:  A Johansson; P A Oberg; G Sedin
Journal:  J Clin Monit Comput       Date:  1999-12       Impact factor: 2.502

10.  Monitoring of respiratory rate in postoperative care using a new photoplethysmographic technique.

Authors:  L Nilsson; A Johansson; S Kalman
Journal:  J Clin Monit Comput       Date:  2000       Impact factor: 2.502

View more
  3 in total

1.  Age and gender do not influence the ability to detect respiration by photoplethysmography.

Authors:  Lena Nilsson; Tomas Goscinski; Anders Johansson; Lars-Göran Lindberg; Sigga Kalman
Journal:  J Clin Monit Comput       Date:  2006-10-11       Impact factor: 2.502

2.  Identifying airway obstructions using photoplethysmography (PPG).

Authors:  Bethany R Knorr-Chung; Susan P McGrath; George T Blike
Journal:  J Clin Monit Comput       Date:  2008-01-25       Impact factor: 2.502

3.  An assessment of algorithms to estimate respiratory rate from the electrocardiogram and photoplethysmogram.

Authors:  Peter H Charlton; Timothy Bonnici; Lionel Tarassenko; David A Clifton; Richard Beale; Peter J Watkinson
Journal:  Physiol Meas       Date:  2016-03-30       Impact factor: 2.833

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.