The accuracy of pneumotachograph measurements during mechanical ventilation.

J W Kreit1, F C Sciurba.   

Abstract

We hypothesized that differences between the conditions under which a pneumotachograph (PT) is calibrated and those during data collection might lead to large errors in measured flow and volume during mechanical ventilation. A Fleisch No. 1 and Fleisch No. 2 and a screen PT were connected to "ideal" tubing configurations that optimized flow characteristics, and to ventilator tubing with and without a Y-connector and endotracheal (ET) tube. Each PT was also evaluated after water had accumulated in its resistive element. Air was passed through each PT configuration, using both a continuous and a pulsatile flow pattern, and collected in a water-seal spirometer. "Measured" and "true" flow and volume were determined from the PT and the spirometer, respectively. Measured flow and volume were falsely low when the PT was adapted to ventilator tubing. Addition of a Y-connector and ET tube caused measured flow and volume to increase, and, in some cases the relationship between measured and true flow became nonlinear. Water accumulation in the PT did not lead to measurement errors. We conclude that when a PT is used during mechanical ventilation, tubing geometry must be identical during calibration and data collection, and that calibration should be performed over the entire range of relevant flows.

Entities:  

Mesh:

Year:  1996        PMID: 8887585     DOI: 10.1164/ajrccm.154.4.8887585

Source DB:  PubMed          Journal:  Am J Respir Crit Care Med        ISSN: 1073-449X            Impact factor:   21.405


  7 in total

1.  The syringe potentiometer: a low-cost device for pneumotachograph calibration.

Authors:  Troy J Cross; Eli F Kelley; Tim A Hardy; Jennifer M J Isautier; Bruce D Johnson
Journal:  J Appl Physiol (1985)       Date:  2019-09-05

2.  Application of the nonlinear methods in pneumocardiogram signals.

Authors:  Nazmi Yılmaz; Mahmut Akıllı; Mustafa Özbek; Tamer Zeren; K Gediz Akdeniz
Journal:  J Biol Phys       Date:  2020-06-11       Impact factor: 1.365

3.  A New Differential Pressure Flow Meter for Measurement of Human Breath Flow: Simulation and Experimental Investigation.

Authors:  Devon Bridgeman; Francis Tsow; Xiaojun Xian; Erica Forzani
Journal:  AIChE J       Date:  2016-01-08       Impact factor: 3.993

4.  Improved accuracy and extended flow range for a Fleisch pneumotachograph.

Authors:  N O Strömberg; M J Grönkvist
Journal:  Med Biol Eng Comput       Date:  1999-07       Impact factor: 2.602

5.  Accuracy of volume measurements in mechanically ventilated newborns: a comparative study of commercial devices.

Authors:  K Roske; B Foitzik; R R Wauer; G Schmalisch
Journal:  J Clin Monit Comput       Date:  1998-08       Impact factor: 2.502

6.  Nonlinear Flow Sensor Calibration with an Accurate Syringe.

Authors:  Paolo Jose Cesare Biselli; Raquel Siqueira Nóbrega; Francisco Garcia Soriano
Journal:  Sensors (Basel)       Date:  2018-07-05       Impact factor: 3.576

7.  Comparison of a micro-electro-mechanical system airflow sensor with the pneumotach in the forced oscillation technique.

Authors:  Xiaohe K Xu; Brian P Harvey; Kenneth R Lutchen; Brian D Gelbman; Stephen L Monfre; Robert E Coifman; Charles E Forbes
Journal:  Med Devices (Auckl)       Date:  2018-12-13
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.