Literature DB >> 3949670

Linearity and temperature control of the Fleisch pneumotachograph.

M R Miller, A C Pincock.   

Abstract

We have investigated the optimal thermal conditions of a Fleisch no. 4 pneumotachograph (PT) necessary for recording maximal forced expiratory maneuvers (MFEM). Our PT assembly was tested with a computer-driven pump and found to be linear up to 14 l/s. Thermocouples (TC) were placed in a peripheral, mid, and a central capillary of the PT. Stable temperature control and consistent PT calibration were best obtained by proportional thermostatic control via the peripheral TC. When the PT was heated to 35 degrees C or above, expirations from either the pump (air at 33 degrees C saturated) or a subject cooled the PT, thus affecting its response. With the PT heated to 30 degrees C, repeated blows caused little change in PT temperature, with no evidence of condensation, thus indicating optimal thermal conditions for recording MFEM.

Entities:  

Mesh:

Year:  1986        PMID: 3949670     DOI: 10.1152/jappl.1986.60.2.710

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  7 in total

1.  The accuracy of portable peak flow meters.

Authors:  M R Miller; S A Dickinson; D J Hitchings
Journal:  Thorax       Date:  1992-11       Impact factor: 9.139

2.  Calibration of Fleisch and screen pneumotachographs for use with various oxygen concentrations.

Authors:  M J Turner; I M MacLeod; A D Rothberg
Journal:  Med Biol Eng Comput       Date:  1990-03       Impact factor: 2.602

3.  Assessment of a new transtelephonic portable spirometer.

Authors:  S Abboud; I Bruderman
Journal:  Thorax       Date:  1996-04       Impact factor: 9.139

4.  Critical evaluation of different objective techniques of nasal airway assessment: a clinical review.

Authors:  P A R Clement; S Halewyck; F Gordts; O Michel
Journal:  Eur Arch Otorhinolaryngol       Date:  2014-01-20       Impact factor: 2.503

5.  Improved accuracy and extended flow range for a Fleisch pneumotachograph.

Authors:  N O Strömberg; M J Grönkvist
Journal:  Med Biol Eng Comput       Date:  1999-07       Impact factor: 2.602

6.  In-airway molecular flow sensing: A new technology for continuous, noninvasive monitoring of oxygen consumption in critical care.

Authors:  Luca Ciaffoni; David P O'Neill; John H Couper; Grant A D Ritchie; Gus Hancock; Peter A Robbins
Journal:  Sci Adv       Date:  2016-08-10       Impact factor: 14.136

7.  A Calibration Device to Compare Body Plethysmographs Among Pediatric Lung Function Laboratories.

Authors:  Bruno Demoulin; Iulia Ioan; Claude Duvivier; Claude Bonabel; Cyril Schweitzer; François Marchal; Silvia Demoulin-Alexikova
Journal:  Front Physiol       Date:  2018-10-09       Impact factor: 4.566

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.