Literature DB >> 11465885

Error analysis of a natural breathing calibration method for respiratory inductive plethysmography.

N O Strömberg1.   

Abstract

Respiratory volumes are measured non-invasively by recording rib cage and abdominal motions using respiratory inductive plethysmography (RIP). Qualitative diagnostic calibration (QDC) of RIP is based on the natural variability in the relative rib-cage-to-abdomen contribution during tidal breathing. ODC does not require subject cooperation but it has previously been shown that accuracy may deteriorate when breathing pattern changes. The aim of this study was to investigate the causes and situations where QDC accuracy deteriorates. The QDC method was compared to PRA (calibration during voluntarily preferential rib cage or abdomen breathing) in ten adults. A reference RIP calibration was obtained from all validation data (REF). The PRA method had better accuracy than the ODC method (p<0.01). The volumetric error ranged between 10% and 136% with QDC and between 5% and 33% with PRA. The PRA calibration factors were within 6% of those from REF, while the QDC rib-cage factor was underestimated by 15% and the abdominal factor was overestimated by 38%. Small natural variability in the relative rib-cage-to-abdomen contribution was related to poor accuracy. Each compartment's variability depended on its magnitude, which is a violation of the QDC assumptions.

Mesh:

Year:  2001        PMID: 11465885     DOI: 10.1007/BF02345285

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  14 in total

1.  Comparison of thoracoabdominal calibration methods in normal human subjects.

Authors:  R Sartene; C Dartus; J L Bernard; M Mathieu; M D Goldman
Journal:  J Appl Physiol (1985)       Date:  1993-11

2.  Measurement of the separate volume changes of rib cage and abdomen during breathing.

Authors:  K Konno; J Mead
Journal:  J Appl Physiol       Date:  1967-03       Impact factor: 3.531

3.  Calibration of respiratory inductive plethysmograph during natural breathing.

Authors:  M A Sackner; H Watson; A S Belsito; D Feinerman; M Suarez; G Gonzalez; F Bizousky; B Krieger
Journal:  J Appl Physiol (1985)       Date:  1989-01

4.  Ventilatory inhomogeneity determined from multiple-breath washouts during sustained microgravity on Spacelab SLS-1.

Authors:  G K Prisk; H J Guy; A R Elliott; M Paiva; J B West
Journal:  J Appl Physiol (1985)       Date:  1995-02

5.  Evaluation of various models for respiratory inductance plethysmography calibration.

Authors:  N O Strömberg; G O Dahlbäck; P M Gustafsson
Journal:  J Appl Physiol (1985)       Date:  1993-03

6.  Postural changes in rib cage and abdominal volume-motion coefficients and their effect on the calibration of a respiratory inductance plethysmograph.

Authors:  P V Zimmerman; S J Connellan; H C Middleton; M V Tabona; M D Goldman; N Pride
Journal:  Am Rev Respir Dis       Date:  1983-02

7.  The respiratory inductive plethysmograph: a new non-invasive monitor of respiration.

Authors:  M A Cohn; A S Rao; M Broudy; S Birch; H Watson; N Atkins; B Davis; F D Stott; M A Sackner
Journal:  Bull Eur Physiopathol Respir       Date:  1982 Jul-Aug

8.  Validation of respiratory inductive plethysmography using different calibration procedures.

Authors:  T S Chadha; H Watson; S Birch; G A Jenouri; A W Schneider; M A Cohn; M A Sackner
Journal:  Am Rev Respir Dis       Date:  1982-06

9.  Multiple-breath washin of helium and sulfur hexafluoride in sustained microgravity.

Authors:  G K Prisk; A R Elliott; H J Guy; S Verbanck; M Paiva; J B West
Journal:  J Appl Physiol (1985)       Date:  1998-01

10.  Computerized determination of pneumotachometer characteristics using a calibrated syringe.

Authors:  M P Yeh; R M Gardner; T D Adams; F G Yanowitz
Journal:  J Appl Physiol Respir Environ Exerc Physiol       Date:  1982-07
View more
  2 in total

1.  Non-invasive respiratory monitoring using long-period fiber grating sensors.

Authors:  M D Petrović; J Petrovic; A Daničić; M Vukčević; B Bojović; Lj Hadžievski; T Allsop; G Lloyd; D J Webb
Journal:  Biomed Opt Express       Date:  2014-03-12       Impact factor: 3.732

2.  Respiratory inductance plethysmography calibration for pediatric upper airway obstruction: an animal model.

Authors:  Robinder G Khemani; Rutger Flink; Justin Hotz; Patrick A Ross; Anoopindar Ghuman; Christopher J L Newth
Journal:  Pediatr Res       Date:  2014-10-03       Impact factor: 3.756

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.