Literature DB >> 9451654

Design and calibration of unicapillary pneumotachographs.

A Giannella-Neto1, C Bellido, R B Barbosa, M F Melo.   

Abstract

This study presents a method for design and calibration of unicapillary pneumotachographs for small-animal experiments. The design, based on Poiseuille's law, defines a set of internal radius and length values that allows for laminar flow, measurable pressure differences, and minimal interference with animal's respiratory mechanics and gas exchange. A third-order polynomial calibration (Pol) of the pressure-flow relationship was employed and compared with linear calibration (Lin). Tests were done for conditions of ambient pressure (Pam) and positive pressure (Ppos) ventilation at different flow ranges. A physical model designed to match normal and low compliance in rats was used. At normal compliance, Pol provided lower errors than Lin for mixed (1-12 ml/s), mean (4-10 ml/s), and high (8-12 ml/s) flow rate calibrations for both Pam and Ppos inspiratory tests (P < 0.001 for all conditions) and expiratory tests (P < 0.001 for all conditions). At low compliance, they differed significantly with 8.6 +/- 4.1% underestimation when Lin at Pam was used in Ppos tests. Ppos calibration, preferably in combination with Pol, should be used in this case to minimize errors (Pol = 0.8 +/- 0.5%, Lin = 6.5 +/- 4.0%, P < 0.0005). Nonlinear calibration may be useful for improvement of flow and volume measurements in small animals during both Pam and Ppos ventilation.

Entities:  

Mesh:

Year:  1998        PMID: 9451654     DOI: 10.1152/jappl.1998.84.1.335

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  3 in total

1.  Design and nonlinear modeling of a sensitive sensor for the measurement of flow in mice.

Authors:  Samer Bou Jawde; Bradford J Smith; Adam Sonnenberg; Jason H T Bates; Béla Suki
Journal:  Physiol Meas       Date:  2018-07-03       Impact factor: 2.833

2.  Improved accuracy and extended flow range for a Fleisch pneumotachograph.

Authors:  N O Strömberg; M J Grönkvist
Journal:  Med Biol Eng Comput       Date:  1999-07       Impact factor: 2.602

3.  Control of positive end-expiratory pressure (PEEP) for small animal ventilators.

Authors:  Antonio Giannella-Neto; Gabriel C da Motta Ribeiro; Edil L Santos; João Hn Soares; Marcelo V Leão Nunes; Frederico C Jandre
Journal:  Biomed Eng Online       Date:  2010-07-30       Impact factor: 2.819

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.