Literature DB >> 10535628

Monte Carlo simulations of the imaging performance of metal plate/phosphor screens used in radiotherapy.

C Kausch1, B Schreiber, F Kreuder, R Schmidt, O Dössel.   

Abstract

The imaging performance of metal plate/phosphor screens which are used for the creation of portal images in radiotherapy is investigated by using Monte Carlo simulations. To this end the modulation transfer function, the noise power spectrum and the detective quantum efficiency [DQE(f)] are calculated for different metals and phosphors and different thicknesses of metal and phosphor for a range of spatial resolutions. The interaction of x-rays with the metal plate/phosphor screen is modeled with the EGS4 electron gamma shower code. Optical transport in the phosphor is modeled by simulating scattering and reabsorption events of individual optical photons. It is shown that metals with a high atomic number perform better than lighter metals in maximizing the DQE(f). It is furthermore shown that the DQE(f) for the metal plate/phosphor screen alone is nearly x-ray quantum absorption limited up to spatial frequencies of 0.4 cycles/mm. In addition, it is argued that the secondary quantum sink of optical photons imposed by the optical chain (mirror, lenses and video camera) leads to a significant degradation of the signal-to-noise ratio at spatial frequencies which are most important for successful registration of portal images. Therefore, the conclusion is that a replacement of the optical chain by a flat array of photodiodes placed directly under the phosphor will lead to a substantial improvement in image quality of portal images.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10535628     DOI: 10.1118/1.598727

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  13 in total

1.  Super-resolution imaging in a multiple layer EPID.

Authors:  Haijian Chen; Joerg Rottmann; Stephen Sf Yip; Daniel Morf; Rony Füglistaller; Josh Star-Lack; George Zentai; Ross Berbeco
Journal:  Biomed Phys Eng Express       Date:  2017-02-21

2.  Determination of radiotherapy X-ray spectra using a screen-film system.

Authors:  H M Garnica-Garza
Journal:  Med Biol Eng Comput       Date:  2008-09-09       Impact factor: 2.602

3.  A Monte Carlo investigation of Swank noise for thick, segmented, crystalline scintillators for radiotherapy imaging.

Authors:  Yi Wang; Larry E Antonuk; Youcef El-Mohri; Qihua Zhao
Journal:  Med Phys       Date:  2009-07       Impact factor: 4.071

4.  Rapid Monte Carlo simulation of detector DQE(f).

Authors:  Josh Star-Lack; Mingshan Sun; Andre Meyer; Daniel Morf; Dragos Constantin; Rebecca Fahrig; Eric Abel
Journal:  Med Phys       Date:  2014-03       Impact factor: 4.071

5.  Evaluation of a hybrid direct-indirect active matrix flat-panel imager using Monte Carlo simulation.

Authors:  Scott Dow; Adrian Howansky; Anthony R Lubinsky; Wei Zhao
Journal:  J Med Imaging (Bellingham)       Date:  2020-05-12

6.  A Monte Carlo study of the impact of phosphor optical properties on EPID imaging performance.

Authors:  Mengying Shi; Marios Myronakis; Yue-Houng Hu; Daniel Morf; Joerg Rottmann; Ross Berbeco
Journal:  Phys Med Biol       Date:  2018-08-20       Impact factor: 3.609

7.  A novel multilayer MV imager computational model for component optimization.

Authors:  Marios Myronakis; Josh Star-Lack; Paul Baturin; Joerg Rottmann; Daniel Morf; Adam Wang; Yue-Houng Hu; Daniel Shedlock; Ross I Berbeco
Journal:  Med Phys       Date:  2017-06-28       Impact factor: 4.071

8.  A piecewise-focused high DQE detector for MV imaging.

Authors:  Josh Star-Lack; Daniel Shedlock; Dennis Swahn; Dave Humber; Adam Wang; Hayley Hirsh; George Zentai; Daren Sawkey; Isaac Kruger; Mingshan Sun; Eric Abel; Gary Virshup; Mihye Shin; Rebecca Fahrig
Journal:  Med Phys       Date:  2015-09       Impact factor: 4.071

9.  Modelling the transport of optical photons in scintillation detectors for diagnostic and radiotherapy imaging.

Authors:  Emilie Roncali; Mohammad Amin Mosleh-Shirazi; Aldo Badano
Journal:  Phys Med Biol       Date:  2017-10-04       Impact factor: 3.609

Review 10.  Monte Carlo methods for device simulations in radiation therapy.

Authors:  Hyojun Park; Harald Paganetti; Jan Schuemann; Xun Jia; Chul Hee Min
Journal:  Phys Med Biol       Date:  2021-09-14       Impact factor: 4.174

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.