Super-resolution imaging in a multiple layer EPID.

Haijian Chen1, Joerg Rottmann1, Stephen Sf Yip1, Daniel Morf2, Rony Füglistaller2, Josh Star-Lack3, George Zentai3, Ross Berbeco1.   

Abstract

A new portal imager consisting of four vertically stacked conventional electronic portal imaging device (EPID) layers has been constructed in pursuit of improved detective quantum efficiency (DQE). We hypothesize that super-resolution (SR) imaging can also be achieved in such a system by shifting each layer laterally by half a pixel relative to the layer above. Super-resolution imaging will improve resolution and contrast-to-noise ratio (CNR) in megavoltage (MV) planar and cone beam computed tomography (MV-CBCT) applications. Simulations are carried out to test this hypothesis with digital phantoms. To assess planar resolution, 2 mm long iron rods with 0.3 × 0.3 mm2 square cross-section are arranged in a grid pattern at the center of a 1 cm thick solid water. For measuring CNR in MV-CBCT, a 20 cm diameter digital phantom with 8 inserts of different electron densities is used. For measuring resolution in MV-CBCT, a digital phantom featuring a bar pattern similar to the Gammex™ phantom is used. A 6 MV beam is attenuated through each phantom and detected by each of the four detector layers. Fill factor of the detector is explicitly considered. Projections are blurred with an estimated point spread function (PSF) before super-resolution reconstruction. When projections from multiple shifted layers are used in SR reconstruction, even a simple shift-add fusion can significantly improve the resolution in reconstructed images. In the reconstructed planar image, the grid pattern becomes visually clearer. In MV-CBCT, combining projections from multiple layers results in increased CNR and resolution. The inclusion of two, three and four layers increases CNR by 40%, 70% and 99%, respectively. Shifting adjacent layers by half a pixel almost doubles resolution. In comparison, using four perfectly aligned layers does not improve resolution relative to a single layer.

Entities:  

Keywords:  EPID; MV-CBCT; portal imaging; super-resolution imaging

Year:  2017        PMID: 28713589      PMCID: PMC5507372          DOI: 10.1088/2057-1976/aa5d20

Source DB:  PubMed          Journal:  Biomed Phys Eng Express        ISSN: 2057-1976


  40 in total

1.  Monte Carlo simulations of the imaging performance of metal plate/phosphor screens used in radiotherapy.

Authors:  C Kausch; B Schreiber; F Kreuder; R Schmidt; O Dössel
Journal:  Med Phys       Date:  1999-10       Impact factor: 4.071

2.  A megavoltage CT scanner for radiotherapy verification.

Authors:  D G Lewis; W Swindell; E J Morton; P M Evans; Z R Xiao
Journal:  Phys Med Biol       Date:  1992-10       Impact factor: 3.609

3.  Performance characterization of megavoltage computed tomography imaging on a helical tomotherapy unit.

Authors:  Sanford L Meeks; Joseph F Harmon; Katja M Langen; Twyla R Willoughby; Thomas H Wagner; Patrick A Kupelian
Journal:  Med Phys       Date:  2005-08       Impact factor: 4.071

4.  Volumetric modulated arc therapy: IMRT in a single gantry arc.

Authors:  Karl Otto
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

5.  Low dose megavoltage cone beam computed tomography with an unflattened 4 MV beam from a carbon target.

Authors:  Bruce A Faddegon; Vincent Wu; Jean Pouliot; Bijumon Gangadharan; Ali Bani-Hashemi
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

6.  Registration of clinical volumes to beams-eye-view images for real-time tracking.

Authors:  Jonathan H Bryant; Joerg Rottmann; John H Lewis; Pankaj Mishra; Paul J Keall; Ross I Berbeco
Journal:  Med Phys       Date:  2014-12       Impact factor: 4.071

7.  Low-dose megavoltage cone-beam CT for radiation therapy.

Authors:  Jean Pouliot; Ali Bani-Hashemi; Josephine Chen; Michelle Svatos; Farhad Ghelmansarai; Matthias Mitschke; Michele Aubin; Ping Xia; Olivier Morin; Kara Bucci; Mack Roach; Paco Hernandez; Zirao Zheng; Dimitre Hristov; Lynn Verhey
Journal:  Int J Radiat Oncol Biol Phys       Date:  2005-02-01       Impact factor: 7.038

8.  Image quality and dose distributions of three linac-based imaging modalities.

Authors:  Yvonne Dzierma; Evemarie Ames; Frank Nuesken; Jan Palm; Norbert Licht; Christian Rübe
Journal:  Strahlenther Onkol       Date:  2014-12-20       Impact factor: 3.621

9.  Residual setup errors and dose variations with less-than-daily image guided patient setup in external beam radiotherapy for esophageal cancer.

Authors:  Chunhui Han; Daniel C Schiffner; Timothy E Schultheiss; Yi-Jen Chen; An Liu; Jeffrey Y C Wong
Journal:  Radiother Oncol       Date:  2011-08-27       Impact factor: 6.280

Review 10.  Megavoltage cone-beam CT: system description and clinical applications.

Authors:  Olivier Morin; Amy Gillis; Josephine Chen; Michèle Aubin; M Kara Bucci; Mack Roach; Jean Pouliot
Journal:  Med Dosim       Date:  2006       Impact factor: 1.482

View more
  3 in total

1.  Leveraging multi-layer imager detector design to improve low-dose performance for megavoltage cone-beam computed tomography.

Authors:  Yue-Houng Hu; Joerg Rottmann; Rony Fueglistaller; Marios Myronakis; Adam Wang; Pascal Huber; Daniel Shedlock; Daniel Morf; Paul Baturin; Josh Star-Lack; Ross Berbeco
Journal:  Phys Med Biol       Date:  2018-01-30       Impact factor: 3.609

Review 2.  Technical Principles of Dual-Energy Cone Beam Computed Tomography and Clinical Applications for Radiation Therapy.

Authors:  Shailaja Sajja; Young Lee; Markus Eriksson; Håkan Nordström; Arjun Sahgal; Masoud Hashemi; James G Mainprize; Mark Ruschin
Journal:  Adv Radiat Oncol       Date:  2019-07-30

3.  Development of a novel high quantum efficiency MV x-ray detector for image-guided radiotherapy: A feasibility study.

Authors:  Jian Liu; Yuan Xu; Aram Teymurazyan; Zisis Papandreou; Geordi Pang
Journal:  Med Phys       Date:  2019-11-04       Impact factor: 4.071

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.