Literature DB >> 30051879

A Monte Carlo study of the impact of phosphor optical properties on EPID imaging performance.

Mengying Shi1, Marios Myronakis, Yue-Houng Hu, Daniel Morf, Joerg Rottmann, Ross Berbeco.   

Abstract

We have developed a Monte Carlo computational model of a clinically employed electronic portal imaging device (EPID), and demonstrated the impact of phosphor optical properties on the imaging performance. The EPID model was built with Geant4 application for tomographic emission. Both radiative and optical transport were included in the model. Modulation transfer function (MTF), normalized noise-power spectrum times the incident x-ray fluence (qNNPS), and detective quantum efficiency (DQE) were calculated for simulated and measured data, and their agreement was quantified by the normalized root-mean-square error (NRMSE). MTF was computed using a 100 µm wide slit tilted by 1.5° and qNNPS was estimated using the Fujita-Lubberts-Swank method. DQE was calculated from MTF and qNNPS data. The NRMSE value was 0.0467 for MTF, 0.0217 for qNNPS, and 0.0885 for DQE, showing good agreement between measurement and simulation. Five major optical properties, phosphor grain size, phosphor thickness, phosphor refractive index, binder refractive index, and packing ratio were tested for their influence on the qNNPS, MTF, and DQE(0) of the model. Generally, the effect on the qNNPS is greater than MTF, and no impact on DQE(0), except from phosphor thickness, was observed. Multiple applications, such as imager design optimization and investigations of the dosimetric performance, are expected to benefit from the validated model.

Entities:  

Mesh:

Year:  2018        PMID: 30051879      PMCID: PMC6147143          DOI: 10.1088/1361-6560/aad647

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  31 in total

1.  Monte Carlo simulations of the imaging performance of metal plate/phosphor screens used in radiotherapy.

Authors:  C Kausch; B Schreiber; F Kreuder; R Schmidt; O Dössel
Journal:  Med Phys       Date:  1999-10       Impact factor: 4.071

2.  A simple method for determining the modulation transfer function in digital radiography.

Authors:  H Fujita; D Y Tsai; T Itoh; K Doi; J Morishita; K Ueda; A Ohtsuka
Journal:  IEEE Trans Med Imaging       Date:  1992       Impact factor: 10.048

Review 3.  A literature review of electronic portal imaging for radiotherapy dosimetry.

Authors:  Wouter van Elmpt; Leah McDermott; Sebastiaan Nijsten; Markus Wendling; Philippe Lambin; Ben Mijnheer
Journal:  Radiother Oncol       Date:  2008-08-14       Impact factor: 6.280

4.  Signal, noise power spectrum, and detective quantum efficiency of indirect-detection flat-panel imagers for diagnostic radiology.

Authors:  J H Siewerdsen; L E Antonuk; Y el-Mohri; J Yorkston; W Huang; I A Cunningham
Journal:  Med Phys       Date:  1998-05       Impact factor: 4.071

5.  X-ray quantum limited portal imaging using amorphous silicon flat-panel arrays.

Authors:  P Munro; D C Bouius
Journal:  Med Phys       Date:  1998-05       Impact factor: 4.071

6.  Optical photon transport in powdered-phosphor scintillators. Part II. Calculation of single-scattering transport parameters.

Authors:  Gavin G Poludniowski; Philip M Evans
Journal:  Med Phys       Date:  2013-04       Impact factor: 4.071

7.  Relative dosimetry using active matrix flat-panel imager (AMFPI) technology.

Authors:  Y El-Mohri; L E Antonuk; J Yorkston; K W Jee; M Maolinbay; K L Lam; J H Siewerdsen
Journal:  Med Phys       Date:  1999-08       Impact factor: 4.071

8.  A novel multilayer MV imager computational model for component optimization.

Authors:  Marios Myronakis; Josh Star-Lack; Paul Baturin; Joerg Rottmann; Daniel Morf; Adam Wang; Yue-Houng Hu; Daniel Shedlock; Ross I Berbeco
Journal:  Med Phys       Date:  2017-06-28       Impact factor: 4.071

9.  A piecewise-focused high DQE detector for MV imaging.

Authors:  Josh Star-Lack; Daniel Shedlock; Dennis Swahn; Dave Humber; Adam Wang; Hayley Hirsh; George Zentai; Daren Sawkey; Isaac Kruger; Mingshan Sun; Eric Abel; Gary Virshup; Mihye Shin; Rebecca Fahrig
Journal:  Med Phys       Date:  2015-09       Impact factor: 4.071

10.  Optical photon transport in powdered-phosphor scintillators. Part 1. Multiple-scattering and validity of the Boltzmann transport equation.

Authors:  Gavin G Poludniowski; Philip M Evans
Journal:  Med Phys       Date:  2013-04       Impact factor: 4.071

View more
  6 in total

Review 1.  Monte Carlo methods for device simulations in radiation therapy.

Authors:  Hyojun Park; Harald Paganetti; Jan Schuemann; Xun Jia; Chul Hee Min
Journal:  Phys Med Biol       Date:  2021-09-14       Impact factor: 4.174

2.  Frequency-dependent optimal weighting approach for megavoltage multilayer imagers.

Authors:  Ingrid Valencia Lozano; Mengying Shi; Marios Myronakis; Paul Baturin; Rony Fueglistaller; Pascal Huber; Mathias Lehmann; Daniel Morf; Dianne Ferguson; Matthew W Jacobson; Thomas Harris; Ross I Berbeco; Christopher L Williams
Journal:  Phys Med Biol       Date:  2021-04-16       Impact factor: 4.174

3.  GPU-accelerated Monte Carlo simulation of MV-CBCT.

Authors:  Mengying Shi; Marios Myronakis; Matthew Jacobson; Dianne Ferguson; Christopher Williams; Mathias Lehmann; Paul Baturin; Pascal Huber; Rony Fueglistaller; Ingrid Valencia Lozano; Thomas Harris; Daniel Morf; Ross I Berbeco
Journal:  Phys Med Biol       Date:  2020-12-02       Impact factor: 4.174

4.  A rapid, accurate image simulation strategy for mega-voltage cone-beam computed tomography.

Authors:  Mengying Shi; Marios Myronakis; Matthew Jacobson; Mathias Lehmann; Dianne Ferguson; Paul Baturin; Pascal Huber; Rony Fueglistaller; Thomas Harris; Ingrid Valencia Lozano; Christopher Williams; Daniel Morf; Ross I Berbeco
Journal:  Phys Med Biol       Date:  2020-07-06       Impact factor: 4.174

5.  A Comprehensive Evaluation of the Application of the Halcyon(2.0) IMRT Technique in Long-Course Radiotherapy for Rectal Cancer.

Authors:  Jiajun Zheng; Yuqing Xia; Li Sun
Journal:  Technol Cancer Res Treat       Date:  2022 Jan-Dec

6.  Evaluating the sensitivity of Halcyon's automatic transit image acquisition for treatment error detection: A phantom study using static IMRT.

Authors:  Xenia Ray; Casey Bojechko; Kevin L Moore
Journal:  J Appl Clin Med Phys       Date:  2019-10-06       Impact factor: 2.102

  6 in total