Diagnostic value of SPECT, PET and PET/CT in the diagnosis of coronary artery disease: A systematic review.

M Al Moudi1, Z Sun, N Lenzo.   

Abstract

PURPOSE: The purpose of the study was to investigate the diagnostic value of SPECT, PET and PET/CT in the diagnosis of coronary artery disease, based on a systematic review.
MATERIAL AND METHODS: A search of PubMed/Medline and Sciencedirect databases in the English-language literature published over the last 24 years was performed. Only studies with at least 10 patients comparing SPECT, PET or combined PET/CT with invasive coronary angiography in the diagnosis of coronary artery disease (50% stenosis) were included for analysis. Sensitivities and specificities estimates pooled across studies were analysed using a Chi-square test.
RESULTS: Twenty-five studies met the selection criteria and were included for the analysis. Ten studies were performed with SPECT alone; while another six studies were performed with PET alone. Five studies were carried out with both PET and SPECT modalities, and the remaining four studies were investigated with integrated PET-CT. The mean value of sensitivity, specificity and accuracy of these imaging modalities for the diagnosis of coronary artery disease was 82% (95%CI: 76 to 88), 76% (95%CI: 70 to 82) and 83% (95%CI: 77 to 89) for SPECT; 91% (95%CI: 85 to 97), 89% (95%CI: 83 to 95) and 89% (95%CI: 83 to 95) for PET; and 85% (95%CI: 79 to 90), 83% (95%CI: 77 to 89) and 88% (95%CI: 82 to 94) for PET/CT, respectively. The diagnostic accuracy of these imaging modalities was dependent on the radiotracers used in these studies, with ammonia resulting in the highest diagnostic value.
CONCLUSION: Our review shows that PET has high diagnostic value for diagnosing coronary artery disease, and this indicates that it is a valuable technique for both detection and prediction of coronary artery disease.

Entities:  

Keywords:  Coronary artery disease; computed tomography; diagnostic value; positron emission tomography; single photon emission computed tomography

Year:  2011        PMID: 22287989      PMCID: PMC3265156          DOI: 10.2349/biij.7.2.e9

Source DB:  PubMed          Journal:  Biomed Imaging Interv J        ISSN: 1823-5530


INTRODUCTION

Coronary artery disease (CAD) remains the leading cause of mortality and morbidity in Western countries [1]. Invasive coronary angiography is currently the gold standard for diagnosis and treatment of CAD; however, it is an invasive procedure associated with risks and complications [2]. Moreover, it is reported that around 20% to 40% of all diagnostic invasive coronary angiography procedures were performed for diagnostic purposes without any interventional procedures being applied [3-5]. Thus, investigation of less invasive imaging modalities is important for reducing or avoiding the use of invasive coronary angiography examinations [4]. Currently, multislice computed tomography (CT) angiography is widely used in clinical practice for the diagnosis of CAD, and its diagnostic accuracy has been significantly enhanced with the recent development of 64-, 256- and 320-slice scanners [6-9]. Studies have shown that multislice CT angiography can be used as a reliable alternative to invasive coronary angiography in selected patients, due to its high sensitivity and specificity [6-9]. Myocardial perfusion imaging with SPECT is a widely established method for non-invasive evaluation of coronary artery stenosis [10]. However, the most important applications of SPECT are in the diagnosis of CAD, prediction of disease prognosis, selection of patients for revascularisation and assessment of acute coronary syndromes. Moreover, SPECT holds special value in some particular patient subgroups [11, 12]. Generally speaking, the sensitivity of stress SPECT for detecting angiographically-defined CAD is consistently above 70%, but in the better-designed studies, it is within the range of 85–90% [13, 14]. Positron emission tomography (PET) has contributed significantly to advancing our understanding of heart physiology and pathophysiology for more than 25 years. The diagnostic accuracy of myocardial perfusion by PET in the assessment of CAD has been reported to be superior to SPECT [15, 16]. PET with rest-stress myocardial perfusion is regarded as an exact imaging modality for diagnosing and managing patients with CAD [16]. Moreover, the combined modality of PET/CT further increases the diagnostic accuracy in CAD [12-16]. Despite promising results reported in the literature [17, 18], the diagnostic value of SPECT and PET to detect CAD has not been well established. This is mainly due to the fact that the diagnostic accuracy reported by these studies is variable and the radiopharmaceuticals used in these studies are different. Thus, the purpose of our study was to investigate the diagnostic value of SPECT, PET and PET/CT when compared to invasive coronary angiography for detection of CAD, based on a systematic review of the current literature.

MATERIALS AND METHODS

A search of the English-language literature was performed using two main databases, PubMed/Medline and ScienceDirect. The search included articles published between 1985 and 2009 on the topics of SPECT, PET and PET/CT in CAD. The research was limited to peer-reviewed articles on human subjects and studies published in the English language. The keywords used for the search were “Positron Emission Tomography”, “Single Photon Emission Computed Tomography”, “integrated Positron Emission Tomography and Computed Tomography”, “Coronary Artery Disease”, “Myocardial perfusion”, “Nuclear Medicine Imaging in cardiac disease”. The reference lists for studies matching these criteria were also reviewed to identify additional articles which were not found through the initial search. The last search was performed in September 2010 to ensure inclusion of all recent publications in the analysis. Articles that met the following criteria were included for analysis: SPECT, PET, or PET/CT studies were performed in patients who underwent myocardial perfusion imaging (MPI) rest/stress test while invasive coronary angiography was used as the standard of reference; at least ten patients were included in each study; diagnosis of CAD was based on >50% stenosis. The reason >50% stenosis was chosen was because it has become a routine clinical practice to consider coronary stenosis >50% as haemodynamically significant [19-21]. Also, the diagnostic value in terms of sensitivity and specificity was reported in the study. The exclusion criteria included: review articles or case study reports; animal or phantom studies; studies dealing with myocardial perfusion without addressing the diagnostic accuracy of coronary artery stenosis or occlusion, and studies including patients treated with coronary stents or bypass grafts. Two reviewers checked the references independently and the following information was extracted from each study: year of publication; number of participants in the study; prevalence of patients with suspected or confirmed CAD; mean age; percentage of male patients affected; type of radiotracer used in each study; rest and stress imaging protocols; diagnostic value of SPECT, PET and PET/CT in terms of sensitivity and specificity; and the accuracy of SPECT, PET and PET/CT for detection of CAD. The main findings were summarised in terms of the extent to which studies were reported to have shown the value of using SPECT, PET and PET-CT to diagnose CAD towards improving patient management and cost-effectiveness. All of the statistical analyses were undertaken using SPSS software version 17.0 (SPSS Inc., Chicago, ILL). Each of the study estimates for sensitivity and specificity were independently combined across studies using one sample test. Comparison was performed by Chi Square test using n-1 degree of freedom to test if there are any significant differences between different imaging modalities (SPECT vs PET, SEPCT vs PET/CT, PET vs PET/CT). Statistical hypotheses (2-tailed) were tested at the 5% level of significance.

RESULTS

Twenty-five studies (with 25 comparisons) met the selection criteria and were included in the analysis [19-43]. Ten of these studies were performed with SPECT alone [19–24, 39–41, 43], while six of the studies were performed with PET alone [30-35]. Five studies were carried out with both PET and SPECT modalities [25-29] and the remaining four studies were investigated with integrated PET/CT [36–38, 42]. The total number of patients included in these studies was 4,114 with 53.5% of the patients suspected of CAD, 72.2 % being male and the mean age of patients being 48-years-old. Table 1 summarises the number of patients, the radiotracers used in each study, and the reported sensitivity, specificity and accuracy with use of SPECT, PET and PET/CT imaging modalities, respectively.
Table 1

Study characteristics of SPECT, PET and PET/CT for detection of coronary artery disease

AuthorsYearPatients (n)Male (%)Mean age (yr)StenosisRadiotracerSensitivitySpecificityAccuracy
Husmann et al162008808536>50%201Thallium77%84%NA
Fallahi et al202008518534NA99mTc-sestamibi91%71%88%
Di Carli et al35200711054.557.3>50%82Rubidium65%75%NA
Cesar et al36200728151.638.3>50%82Rubidium93%75%91%
Sampson et al3720071025937>50%82Rubidium93%83%85%
Bateman et al112006855265>50%99mTc-sestamibi82%73%79%
Elhendy et al2120013327757>50%99mTc-sestamibi77%74%77%
Leoncini et al222001339337NA99mTc-sestamibi85%55%NA
Nakamura et al231999818037>50%201Thallium & 99mTc-sestamibi83%99%95%
Levine et al241999507636NA99mTc-sestamibi86%55%85%
Milavetz et al2519982097736.5>50%99mTc-sestamibi95%73%88%
Williams et al29199428775NA>50%82Rubidium87%88%88%
Simone et al30199222580NA>50%82Rubidium92%91%91%
Marwick et al31199274NA34>50%82Rubidium90%100%91%
Grover-McKay et al321992318434.5>50%82Rubidium100%73%87%
Stewart et al2619918164.335>50%201Thallium87%53%78%
Go et al271990202NANA>50%201Thallium76%80%77%
Demer et al33198919374.1NA>50%82Rubidium & 13N ammonia83%95%85%
Tamaki et al28198851NA56.1>50%201Thallium81%92%NA
Gould et al34198650NANA>50%82Rubidium & 13N ammonia95%100%97%

NA-not available

Study characteristics of SPECT, PET and PET/CT for detection of coronary artery disease NA-not available The degree of coronary artery stenosis was assessed based on the criterion of >50%, which was determined by invasive coronary angiography in all studies. Of these 20 studies, 82Rubidium was the most commonly-used radiopharmaceutical which was utilised in 10 studies [26–28, 30–33, 36–38]; 99mTc-Sestamibi was used in seven studies [19–21, 23, 24, 26, 41]; 201Thallium was used in four studies [25, 26, 28, 29]; a combination of 201Thallium and 99mTc-Sestamibi was used in one study [22]; 99mTc-Tetrofosmin was used in three studies [39, 40, 43]; and combinations of 13N Ammonia and 82Rubidium were used in the remaining two studies [34, 35].

Analysis of diagnostic value of SPECT in CAD

A total of 2,208 patients were included in 15 SPECT studies based on significant CAD which was determined by visual assessment of coronary angiography. Figure 2 shows the mean sensitivity, specificity and accuracy of SPECT for diagnosis of CAD. As shown in the figure, the diagnostic value of SPECT was moderate when compared to invasive coronary angiography.
Figure 2

Overall pooled mean diagnostic value of SPECT, PET and PET/CT for detection of coronary artery disease.

Flow chart shows the searching strategy of eligible references. Overall pooled mean diagnostic value of SPECT, PET and PET/CT for detection of coronary artery disease.

Analysis of diagnostic value of PET in CAD

1,376 patients were included in another 11 studies performed with PET tests based on significant CAD which was determined by visual assessment of coronary angiography. Figure 2 shows the mean sensitivity, specificity and accuracy of PET for diagnosis of CAD. As shown in the figure, PET imaging was found to have high diagnostic value in the detection of CAD.

Analysis of diagnostic value of PET/CT in CAD

518 patients were included in four studies performed with PET/CT studies based on significant CAD which was determined by visual assessment of coronary angiography. Again Figure 2 demonstrates that moderate sensitivity, specificity and accuracy of SPECT were reached for diagnosis of CAD.

Comparison of SPECT, PET and PET/CT

There is a significant difference in sensitivity, specificity and accuracy between PET and SPECT, PET and PET/CT, SPECT and PET/CT for the diagnosis of CAD (p < 0.05), with PET demonstrating the highest diagnostic value among these three imaging modalities as shown in Figure 2.

Analysis of diagnostic value for assessment of individual coronary artery disease

Table 2 demonstrates the diagnostic value of SPECT, PET and PET/CT in three studies with five comparisons based on analysis of three main coronary arteries.
Table 2

Mean diagnostic value of SPECT, PET and PET/CT for detection of coronary artery disease by individual coronary branches.

Individual vessel CAD using 50% stenosisRadiotracerSensitivitySpecificityAccuracy
SPECTPETPET/CTSPECTPETPET/CTSPECTPETPET/CTSPECTPETPET/CT
Bateman et al11 >50% stenosis99mTc-sestamibi/ 82Rubidium99mTc-sestamibi/ 82Rubidium
LAD61%79%92%95%75%87%
LCx33%58%86%93%68%79%
RCA60%58%87%100%73%78%
Tamaki et al28 >50% stenosis201Thallium/ 13N ammonia201Thallium/ 13N ammoniaNANA
LAD90%93%89%100%
LCx65%85%93%90%
RCA79%76%95%86%
Cesar et al36 >50% stenosis82Rubidium
LAD70%69%70%
LCx76%86%83%
RCA66%92%77%
Mean diagnostic value of SPECT, PET and PET/CT for detection of coronary artery disease by individual coronary branches. Figures 3 to 5 demonstrate the overall results of sensitivity, specificity and accuracy analysed with three different nuclear medicine modalities at left anterior descending (LAD), left circumflex (LCx) and right coronary artery (RCA). As shown in the figures, PET has the highest diagnostic value among the 3 imaging modalities for diagnosis of CAD.
Figure 3

Pooled diagnostic value of SPECT for detection of coronary artery disease based on individual coronary artery assessment.

Figure 5

Pooled diagnostic value of PET/CT for detection of coronary artery disease based on individual coronary artery assessment.

Pooled diagnostic value of SPECT for detection of coronary artery disease based on individual coronary artery assessment. Pooled diagnostic value of PET for detection of coronary artery disease based on individual coronary artery assessment. Pooled diagnostic value of PET/CT for detection of coronary artery disease based on individual coronary artery assessment.

Analysis of effects of different Radiotracers on diagnostic value

Since different types of radiotracers were used in these 20 studies, analyses of the diagnostic value of variable radiotracers for detection of CAD were investigated. Table 3 shows the radiotracers used in these studies and their corresponding diagnostic value. As demonstrated in the table, using ammonia as a radiotracer produced the highest diagnostic value for detection of CAD.
Table 3

Mean diagnostic value of nuclear medicine imaging with use of different radiotracers.

RadiotracerPatientMaleMean ageStenosisSensitivitySpecificityAccuracy
201Thallium41474.642.350%80%(95% CI: 74 to 86 )77%(95% CI: 71 to 83 )78%(95% CI: 72 to 84 )
99mTc-sestamibi76076.645.750%86%(95% CI: 80 to 92 )66%(95% CI: 60 to 72 )83%(95% CI: 77 to 89 )
201Thallium & 99mTc-sestamibi81803750%83%(95% CI: 77 to 89 )99%(95% CI: 93 to 100 )95%
13N ammonia1217142.550%92%(95% CI: 86 to 98 )86%(95% CI: 80 to 92 )90%(95% CI: 84 to 96 )
82Rubidium9857142.550%90%(95% CI: 84 to 96 )88%(95% CI: 82 to 94 )92%(95% CI: 86 to 98 )
82Rubidium & 13N ammonia24374NA50%89%(95% CI: 83 to 95)97%(95% CI: 91 to 100 )91%(95% CI: 75 to 87 )
Mean diagnostic value of nuclear medicine imaging with use of different radiotracers. Figure 6 shows the differences in sensitivity and specificity between both 201Thallium and 99mTc-sestamibi for the diagnosis of CAD (p < 0.05), and also significant differences in the specificity and accuracy between both 201Thallium and 99mTc-sestamibi and individual radiotracers for the diagnosis of CAD (p < 0.05).
Figure 6

Pooled diagnostic value of nuclear medicine imaging with use of variable radiotracers for detection of coronary artery disease.

Pooled diagnostic value of nuclear medicine imaging with use of variable radiotracers for detection of coronary artery disease. Significant differences in sensitivity and accuracy was found between 13N ammonia, 82Rubidium and both 13N ammonia with 82Rubidium for the diagnosis of CAD (p < 0.05) as shown in Figure 6. Significant differences were found in the sensitivity and specificity between use of combined radiotracers (13N ammonia and 82Rubidium, 201Thallium and 99mTc-sestamibi) and use of individual radiotracers alone for the diagnosis of CAD (p < 0.05).

DISCUSSION

This systematic review presents three significant findings which are considered to be important from a clinical perspective. First, the diagnostic value of SPECT and PET/CT in the detection of CAD is moderate when compared to invasive coronary angiography. Second, PET has higher sensitivity and specificity than SPECT or PET/CT for detection of CAD, indicating the increasing diagnostic accuracy of PET in cardiac imaging. Lastly, there are significant differences when different radiotracers are used for the diagnosis of CAD, with the use of combined radiotracers resulting in improved diagnostic value. SPECT has been used as a routine technique in clinical practice for myocardial perfusion imaging for decades [28]. Previous studies have shown that the diagnostic value of SPECT in cardiac imaging is variable, ranging from low to moderate [29]. Di Carli et al. [44] compared three studies using SPECT with PET, looking particularly at the diagnostic accuracy for detection of CAD. Only the sensitivity and specificity were provided in their study while the analysis of diagnostic accuracy was not identified. This analysis confirms their results to a greater extent, as the mean sensitivity, specificity and accuracy of SPECT for detection of CAD are moderate. This indicates that SPECT has not reached the diagnostic accuracy to be considered as a reliable technique for assessment of CAD. PET has been used more recently in cardiac imaging, and early results look promising [45]. PET offers potential advantages in a clinical practice over myocardial perfusion scintigraphy [46]. PET is able to assess myocardial blood flow and is superior in detecting multivessel disease [47]. Our analysis identifies PET as having the highest diagnostic value for CAD among the three different nuclear imaging modalities analysed. Husmann et al. [26] compared SPECT and PET in respect to diagnostic accuracy of myocardial perfusion imaging. Only the sensitivity and specificity were reported in their study, while the diagnostic accuracy was not available. In contrast, the sensitivity, specificity and accuracy of PET for detection of CAD were analysed in our report. This review provides a comprehensive analysis of the diagnostic value of these nuclear modalities, including sensitivity, specificity and accuracy. Thus, it is believed that the analysis offers additional and valuable diagnostic information, as compared to the previous reports in the literature. Recently, cardiac imaging has been further enhanced by the use of integrated PET/CT, a combined modality which provides the considerable benefit of anatomical and physiologic assessment in patients with CAD [36, 37]. PET/CT allows precise detection and localisation of CAD [38]. CT coronary angiography provides superior anatomical details but lacks the functional information of cardiac perfusion. The latest refinements in CT technology, including multidetector CT with faster gantry rotations, and dual-source devices, have advanced CT angiography as a promising alternative to conventional angiography in the diagnosis of CAD selected patients [48]. Recent studies have shown that 64-slice CTA has high sensitivity (73%- 100%) and specificity (90%-90%) in the detection of CAD [49-51]. PET offers evidence of sub-clinical coronary atherosclerosis as it is superior in demonstrating metabolic activities, but its spatial resolution is limited when demonstrating coronary anatomical structures [47]. Thus, combined PET/CT overcomes the limitations of each individual modality while maximising the advantages of both PET and CT in cardiac imaging [44-46]. However, the analysis of integrated PET/CT for detection of CAD was not as good as initially expected since PET/CT was shown to have moderate sensitivity, specificity and accuracy. This may be due to the selection of patients with different risk factors in the studies analysed. Therefore, results of this analysis should be interpreted with caution. PET/CT may show improved diagnostic accuracy in other areas, such as tumour imaging, but not in the diagnosis of CAD, based on this analysis. This analysis also involves a comparison of radiotracers used in SPECT and PET imaging which includes seven different types of radioisotopes, namely 201Thallium, 99mTc-tetrofosmin, 99mTc-Sestamibi, a combination of 201Thallium and 99mTc-Sestamibi, 13N Ammonia, 82Rubidium, and a combination of 13N Ammonia and 82Rubidium. The comparative analysis indicates significant benefits of using 13N ammonia for MPI to detect CAD by PET, leading to the highest sensitivity and accuracy. Both 13N ammonia and 82Rubidium have significantly high specificity in MPI by PET. PET imaging with use of 13N ammonia, 82Rubidium, and a combination of 13N ammonia and 82Rubidium for diagnosis of CAD, has been found to result in significant differences in sensitivity, specificity and accuracy than those using 201Thallium, 99mTc-sestamibi, and a combination of 201Thallium and 99mTc-sestamibi by SPECT imaging. This is consistent with results reported by other studies. Go and colleagues [28] compared PET and SPECT in 202 patients. Their results showed there was no significant difference between PET imaging with use of 82Rubidium and SPECT imaging with 201Thallium. Tamaki and colleagues [29] compared 13N ammonia PET with 201Thallium SPECT and reported similar findings. Hence, this analysis confirms that 13N ammonia PET and 201Thallium SPECT provide high diagnostic value for detection of CAD. In addition, the analysis of individual coronary arteries demonstrates the superiority of PET over the other two modalities, but a significant difference in diagnostic value was only found between PET and SPECT, PET/CT in LAD. PET/CT was found to be significantly higher than PET in the assessment of RCA in terms of diagnostic accuracy. However, only a few studies presented the analysis of individual coronary arteries, thus a robust conclusion cannot be drawn based on the current analyses. There were some limitations identified in this study which need to be addressed. First, most of the studies did not provide detailed numbers of true positive, true negative cases, thus this prevented the authors from performing an accurate analysis of the diagnostic value of these modalities. Second, studies currently under review or submitted for publication were not included, although the authors did try to cover as many articles as possible in the search. Third, diagnostic value reported in each study was dependent on the radiotracers used, thus results should be interpreted with caution. Fourth, there exists variability among readers to interpret the angiographic images in terms of the degree of stenosis, for example, 50% or more stenosis [52]. Last, this analysis was restricted to English language literature, which could introduce biased opinion to the results. PET/CT has more potential advantages because it integrated two modalities but not many studies were found. In conclusion, this analysis shows that PET has higher sensitivity, specificity and accuracy for detection of CAD than SPECT and PET/CT. PET can be used as a reliable, less invasive modality for functional analysis of patients suspected of CAD. Further studies comprising a large sample size are needed to verify these results.
  50 in total

1.  Assessment of coronary artery disease severity by positron emission tomography. Comparison with quantitative arteriography in 193 patients.

Authors:  L L Demer; K L Gould; R A Goldstein; R L Kirkeeide; N A Mullani; R W Smalling; A Nishikawa; M E Merhige
Journal:  Circulation       Date:  1989-04       Impact factor: 29.690

2.  A retrospective study of the diagnostic accuracy of a community hospital-based PET center for the detection of coronary artery disease using rubidium-82.

Authors:  B R Williams; N A Mullani; D E Jansen; B A Anderson
Journal:  J Nucl Med       Date:  1994-10       Impact factor: 10.057

3.  Dobutamine technetium-99m tetrofosmin SPECT imaging for the diagnosis of coronary artery disease in patients with limited exercise capacity.

Authors:  A Elhendy; F B Sozzi; R Valkema; R T van Domburg; J J Bax; J R Roelandt
Journal:  J Nucl Cardiol       Date:  2000 Nov-Dec       Impact factor: 5.952

4.  Comparison of rubidium-82 positron emission tomography and thallium-201 SPECT imaging for detection of coronary artery disease.

Authors:  R E Stewart; M Schwaiger; E Molina; J Popma; G M Gacioch; M Kalus; S Squicciarini; Z R al-Aouar; A Schork; D E Kuhl
Journal:  Am J Cardiol       Date:  1991-06-15       Impact factor: 2.778

5.  Incremental prognostic value of myocardial perfusion single photon emission computed tomography for the prediction of cardiac death: differential stratification for risk of cardiac death and myocardial infarction.

Authors:  R Hachamovitch; D S Berman; L J Shaw; H Kiat; I Cohen; J A Cabico; J Friedman; G A Diamond
Journal:  Circulation       Date:  1998-02-17       Impact factor: 29.690

6.  Functional assessment with electrocardiographic gated single-photon emission computed tomography improves the ability of technetium-99m sestamibi myocardial perfusion imaging to predict myocardial viability in patients undergoing revascularization.

Authors:  M G Levine; C C McGill; A W Ahlberg; M P White; S Giri; B Shareef; D Waters; G V Heller
Journal:  Am J Cardiol       Date:  1999-01-01       Impact factor: 2.778

Review 7.  Clinical myocardial perfusion PET/CT.

Authors:  Marcelo F Di Carli; Sharmila Dorbala; Jolene Meserve; Georges El Fakhri; Arkadiusz Sitek; Stephen C Moore
Journal:  J Nucl Med       Date:  2007-05       Impact factor: 10.057

8.  Diagnostic accuracy of myocardial perfusion imaging with single photon emission computed tomography and positron emission tomography: a comparison with coronary angiography.

Authors:  Lars Husmann; Mischa Wiegand; Ines Valenta; Oliver Gaemperli; Tiziano Schepis; Patrick T Siegrist; Mehdi Namdar; Christophe A Wyss; Hatem Alkadhi; Philipp A Kaufmann
Journal:  Int J Cardiovasc Imaging       Date:  2007-12-25       Impact factor: 2.357

9.  Diagnostic accuracy of rest/stress ECG-gated Rb-82 myocardial perfusion PET: comparison with ECG-gated Tc-99m sestamibi SPECT.

Authors:  Timothy M Bateman; Gary V Heller; A Iain McGhie; John D Friedman; James A Case; Jan R Bryngelson; Ginger K Hertenstein; Kelly L Moutray; Kimberly Reid; S James Cullom
Journal:  J Nucl Cardiol       Date:  2006 Jan-Feb       Impact factor: 5.952

10.  Diagnostic accuracy of rubidium-82 myocardial perfusion imaging with hybrid positron emission tomography/computed tomography in the detection of coronary artery disease.

Authors:  Uchechukwu K Sampson; Sharmila Dorbala; Atul Limaye; Raymond Kwong; Marcelo F Di Carli
Journal:  J Am Coll Cardiol       Date:  2007-02-26       Impact factor: 24.094

View more
  9 in total

1.  Transient ischemic dilation in SPECT myocardial perfusion imaging for prediction of severe coronary artery disease in diabetic patients.

Authors:  Mario Petretta; Wanda Acampa; Stefania Daniele; Maria Piera Petretta; Carmela Nappi; Roberta Assante; Emilia Zampella; Pierluigi Costanzo; Pasquale Perrone-Filardi; Alberto Cuocolo
Journal:  J Nucl Cardiol       Date:  2012-10-23       Impact factor: 5.952

2.  SPECT vs CT: CT is not the first line test for the diagnosis and prognosis of stable coronary artery disease.

Authors:  Zachary J Trzaska; Mylan C Cohen
Journal:  J Nucl Cardiol       Date:  2013-06       Impact factor: 5.952

3.  Sudden cardiac death after repair of anomalous origin of left coronary artery from right sinus of Valsalva with an interarterial course : Case report and review of the literature.

Authors:  A L Nguyen; F Haas; J Evens; J M P J Breur
Journal:  Neth Heart J       Date:  2012-11       Impact factor: 2.380

4.  Comorbid conditions in individuals assessed by SPECT: Study of a reference cardiology center in Mexico City.

Authors:  Neftali Eduardo Antonio-Villa; Nilda Espínola-Zavaleta; Isabel Carvajal-Juárez; Alondra Noe Flores-Garcia; Erick Alexanderson-Rosas
Journal:  J Nucl Cardiol       Date:  2019-05-16       Impact factor: 5.952

Review 5.  Searching for novel PET radiotracers: imaging cardiac perfusion, metabolism and inflammation.

Authors:  Caitlund Q Davidson; Christopher P Phenix; T C Tai; Neelam Khaper; Simon J Lees
Journal:  Am J Nucl Med Mol Imaging       Date:  2018-06-05

6.  Update of the Brazilian Guideline on Nuclear Cardiology - 2020.

Authors:  Luiz Eduardo Mastrocola; Barbara Juarez Amorim; João Vicente Vitola; Simone Cristina Soares Brandão; Gabriel Blacher Grossman; Ronaldo de Souza Leão Lima; Rafael Willain Lopes; William Azem Chalela; Lara Cristiane Terra Ferreira Carreira; José Roberto Nolasco de Araújo; Cláudio Tinoco Mesquita; José Claudio Meneghetti
Journal:  Arq Bras Cardiol       Date:  2020-02       Impact factor: 2.000

7.  Amino Acid Transporters as Potential Therapeutic Targets in Thyroid Cancer.

Authors:  Keisuke Enomoto; Muneki Hotomi
Journal:  Endocrinol Metab (Seoul)       Date:  2020-06-24

8.  Changes in ventricular depolarisation vectors during exercise caused by regional myocardial ischaemia.

Authors:  Cameruddin W Vellani; Satwat Hashmi; Sadia Mahmud; Mohammad Yusuf; Safia Awan; Khawar Kazmi
Journal:  Sci Rep       Date:  2019-11-08       Impact factor: 4.379

9.  Use of coronary CT angiography in the diagnosis of patients with suspected coronary artery disease: findings and clinical indications.

Authors:  Zhong-Hua Sun; Yu-Pin Liu; Dong-Jin Zhou; Yan Qi
Journal:  J Geriatr Cardiol       Date:  2012-06       Impact factor: 3.327

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.