Literature DB >> 11295691

Preliminary clinical results of photon energy recovery in simultaneous rest Tl-201/stress Tc-99m sestamibi myocardial SPECT.

P Hannequin1, P Weinmann, J Mas, S Vinot.   

Abstract

BACKGROUND: The purpose of this study is to report the first clinical results obtained with the spectral deconvolution technique photon energy recovery (PER) for crosstalk correction in simultaneous rest thallium 201/stress technetium 99m sestamibi myocardial perfusion single photon emission computed tomography (SPECT). METHODS AND
RESULTS: Thirty-four patients with suspected coronary artery disease received Tl-201 (111-130 MBq) at rest, followed by single SPECT. Tc-99m sestamibi (444-518 MBq) was then injected at stress, followed by dual SPECT. Single SPECT data were processed to obtain the following data sets: single raw (conventional) Tl-201 and single PER (scatter-corrected) Tl-201. Dual SPECT data were processed to obtain the following data sets: dual raw Tl-201, dual PER (scatter- and crosstalk-corrected) Tl-201, dual raw Tc-99m, and dual PER (scatter-corrected) Tc-99m. All data sets were automatically analyzed with Cedars-Sinai Quantitative Perfusion SPECT software to derive the relative segmental uptake, the summed score, and the summed difference score. The relative segmental uptake, the summed score, and the number of patients with significant reversibility (summed difference score >2) were 74.84% +/- 12.79%, 3.44 +/- 3.07, and 13, respectively, for single raw Tl-201; 80.5% +/- 10.18%, 1.97 +/- 2.25, and 20, respectively, for dual raw Tl-201; 69.47% +/- 14.08%, 6.41 +/- 3.68, and 17, respectively, for single PER Tl-201; and 69.99% +/- 13.39%, 6.58 +/- 3.63, and 17, respectively, for dual PER Tl-201. The differences between single and dual raw Tl-201 data sets were highly significant, whereas there was no significant difference between PER-corrected Tl-201 data sets.
CONCLUSIONS: PER is quantitatively efficient to correct for crosstalk in patients investigated with simultaneous rest Tl-201/stress Tc-99m sestamibi myocardial SPECT.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11295691     DOI: 10.1067/mnc.2001.111799

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  29 in total

Review 1.  Clinical application of rest thallium-201/Stress technetium-99m sestamibi dual isotope myocardial perfusion single-photon emission computed tomography.

Authors:  R Hachamovitch
Journal:  Cardiol Rev       Date:  1999 Mar-Apr       Impact factor: 2.644

2.  Feasibility of simultaneous dual-isotope myocardial perfusion acquisition using a lower dose of sestamibi.

Authors:  C G Kwok; S Wu; H P Tsang; H W Strauss
Journal:  Eur J Nucl Med       Date:  1997-03

3.  Effects of scatter correction on the measurement of infarct size from SPECT cardiac phantom studies.

Authors:  M K O'Connor; C Caiati; T F Christian; R J Gibbons
Journal:  J Nucl Med       Date:  1995-11       Impact factor: 10.057

4.  Compton scatter compensation using the triple-energy window method for single- and dual-isotope SPECT.

Authors:  T Ichihara; K Ogawa; N Motomura; A Kubo; S Hashimoto
Journal:  J Nucl Med       Date:  1993-12       Impact factor: 10.057

5.  A new dual-isotope convolution cross-talk correction method: a Tl-201/Tc-99m SPECT cardiac phantom study.

Authors:  K Knesaurek
Journal:  Med Phys       Date:  1994-10       Impact factor: 4.071

6.  Simultaneous dual-radionuclide imaging: are the images trustworthy?

Authors:  J M Links
Journal:  Eur J Nucl Med       Date:  1996-10

7.  Enhanced cross-talk correction technique for simultaneous dual-isotope imaging: a TL-201/Tc-99m myocardial perfusion SPECT dog study.

Authors:  K Knesaurek; J Machac
Journal:  Med Phys       Date:  1997-12       Impact factor: 4.071

8.  Simultaneous dual-isotope technetium-99m/thallium-201 cardiac SPET imaging using a projection-dependent spilldown correction factor.

Authors:  G J Hademenos; M Dahlbom; E J Hoffman
Journal:  Eur J Nucl Med       Date:  1995-05

9.  Separate acquisition rest thallium-201/stress technetium-99m sestamibi dual-isotope myocardial perfusion single-photon emission computed tomography: a clinical validation study.

Authors:  D S Berman; H Kiat; J D Friedman; F P Wang; K van Train; L Matzer; J Maddahi; G Germano
Journal:  J Am Coll Cardiol       Date:  1993-11-01       Impact factor: 24.094

10.  Comparative prognostic value of automatic quantitative analysis versus semiquantitative visual analysis of exercise myocardial perfusion single-photon emission computed tomography.

Authors:  D S Berman; X Kang; K F Van Train; H C Lewin; I Cohen; J Areeda; J D Friedman; G Germano; L J Shaw; R Hachamovitch
Journal:  J Am Coll Cardiol       Date:  1998-12       Impact factor: 24.094

View more
  2 in total

1.  Impact of photon energy recovery on the assessment of left ventricular volume using myocardial perfusion SPECT.

Authors:  Alain Manrique; Anne Hitzel; Pierre Véra
Journal:  J Nucl Cardiol       Date:  2004 May-Jun       Impact factor: 5.952

2.  Optimisation of simultaneous tl-201/tc-99m dual isotope reconstruction with monte-carlo-based scatter correction.

Authors:  Tuija Kangasmaa; Jyrki Kuikka; Antti Sohlberg
Journal:  Int J Mol Imaging       Date:  2012-11-19
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.