Literature DB >> 19152134

Intra-patient reproducibility of myocardial SPECT imaging with 201Tl.

Barbra E Backus1, Frederik A Verburg, R Leo Romijn, Mark W Konijnenberg, Freek J Beekman, J Fred Verzijlbergen.   

Abstract

BACKGROUND: To define the physical and clinical reproducibility of (201)Tl myocardial perfusion SPECT (MPS), this study assesses the variation between two repeated rest (201)Tl MPS with repositioning only, with a two-hour time interval and with phantom measurements as a reference.
METHODS: Three anthropomorphic thorax phantoms were filled with (201)Tl. For each phantom five repeated (201)Tl MPS were obtained. In addition, in 20 patients repeated (201)Tl rest-MPS and in 26 patients early and delayed (201)Tl rest-MPS were performed. Quantitative analysis was done using MunichHeart. Statistical methods were used to calculate variability. Visual analysis was performed by 2 independent observers.
RESULTS: The average variation between repeated phantom MPS was 0.5% (95% confidence interval (CI): -0.4% to 1.4%). For patient scans this was -5.0% (95% CI: -2.5% to -7.5%) and between early and delayed (201)Tl MPS -15.5% (95% CI: -11.7% to -19.3%). Visual assessment revealed no clinical significant differences between rest (201)Tl and repeated or delayed (201)Tl MPS.
CONCLUSIONS: Repositioning in phantom (201)Tl MPS does not cause significant variation. Repeated (201)Tl MPS in patients shows 5.0% decrease of (201)Tl in 30 minutes, which increases to 15% during a two-hour time interval without quantitative or visual regional differences. This decrease indicates a time-related washout of (201)Tl, but does not change clinical diagnosis.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19152134     DOI: 10.1007/s12350-008-9011-7

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  9 in total

1.  Feasibility of simultaneous stress 99mTc-sestamibi/rest 201Tl dual-isotope myocardial perfusion SPECT in the detection of coronary artery disease.

Authors:  M Nakamura; K Takeda; T Ichihara; N Motomura; H Shimizu; Y Saito; Y Nomura; N Isaka; T Konishi; T Nakano
Journal:  J Nucl Med       Date:  1999-06       Impact factor: 10.057

2.  Effect of mechanically simulated diaphragmatic respiratory motion on myocardial SPECT processed with and without attenuation correction.

Authors:  Alexander G Pitman; Victor Kalff; Bruce Van Every; Borghild Risa; Leighton R Barnden; Michael J Kelly
Journal:  J Nucl Med       Date:  2002-09       Impact factor: 10.057

3.  Clinical validation of simultaneous dual-isotope myocardial scintigraphy.

Authors:  Pierre Weinmann; Marc Faraggi; Jean Luc Moretti; Pascal Hannequin
Journal:  Eur J Nucl Med Mol Imaging       Date:  2002-10-19       Impact factor: 9.236

4.  A comparison of 180 degrees and 360 degrees acquisition for attenuation-compensated thallium-201 SPECT images.

Authors:  K J LaCroix; B M Tsui; B H Hasegawa
Journal:  J Nucl Med       Date:  1998-03       Impact factor: 10.057

5.  Contributions of subdiaphragmatic activity, attenuation, and diaphragmatic motion to inferior wall artifact in attenuation-corrected Tc-99m myocardial perfusion SPECT.

Authors:  Alexander G Pitman; Victor Kalff; Bruce Van Every; Borghild Risa; Leighton R Barnden; Michael J Kelly
Journal:  J Nucl Cardiol       Date:  2005 Jul-Aug       Impact factor: 5.952

6.  Myocardial kinetics of thallium and potassium in man.

Authors:  A L'Abbate; A Biagini; C Michelassi; A Maseri
Journal:  Circulation       Date:  1979-10       Impact factor: 29.690

7.  Reproducibility of polar map generation and assessment of defect severity and extent assessment in myocardial perfusion imaging using positron emission tomography.

Authors:  S G Nekolla; C Miethaner; N Nguyen; S I Ziegler; M Schwaiger
Journal:  Eur J Nucl Med       Date:  1998-09

8.  Simultaneous (99m)Tc/(201)Tl dual-isotope SPET with Monte Carlo-based down-scatter correction.

Authors:  H W A M de Jong; F J Beekman; M A Viergever; P P van Rijk
Journal:  Eur J Nucl Med Mol Imaging       Date:  2002-05-25       Impact factor: 9.236

9.  Myocardial thallium-201 kinetics in normal and ischemic myocardium.

Authors:  A M Grunwald; D D Watson; H H Holzgrefe; J F Irving; G A Beller
Journal:  Circulation       Date:  1981-09       Impact factor: 29.690

  9 in total
  2 in total

1.  A study of SPECT/CT camera stability for quantitative imaging.

Authors:  Wendy A McDougald; Robert S Miyaoka; Adam M Alessio; Robert L Harrison; Thomas K Lewellen
Journal:  EJNMMI Phys       Date:  2016-07-29

2.  Accuracy of washout rate analysis for thallium-201 single-photon emission computed tomography myocardial perfusion imaging using cadmium zinc telluride detectors: A phantom study.

Authors:  Masaru Ishihara; Masahisa Onoguchi; Takayuki Shibutani
Journal:  JRSM Cardiovasc Dis       Date:  2020-01-13
  2 in total