Literature DB >> 23143711

Basic imaging properties of an indirect flat-panel detector system employing irradiation side sampling (ISS) technology for chest radiography: comparison with a computed radiographic system.

Nobukazu Tanaka1, Yuki Yano, Hidetake Yabuuchi, Tsutomu Akasaka, Masayuki Sasaki, Masafumi Ohki, Junji Morishita.   

Abstract

The image quality and potential usefulness for patient skin-dose reduction of a newly developed flat-panel detector (FPD) system employing irradiation side sampling (ISS) were investigated and compared to a conventional computed radiography (CR) system. We used the X-ray beam quality of RQA 9 as noted in the standard evaluation method by the International Electrotechnical Commission 62220-1 to evaluate the image quality of the detector for chest radiography. The presampled modulation transfer function (MTF) of the ISS-FPD system was slightly higher than that of the CR system in the horizontal direction at more than 2.2 cycles/mm. However, the presampled MTF of the ISS-FPD system was slightly lower than that of the CR system in the vertical direction. The Wiener spectrum of the ISS-FPD system showed a 50-65 % lesser noise level than that of the CR system under the same exposure condition. The detective quantum efficiency of the ISS-FPD system was at least twice as great as that of the CR system. We conclude that the ISS-FPD system has the potential to reduce the patient skin dose compared to a conventional CR system for chest radiography.

Entities:  

Mesh:

Year:  2012        PMID: 23143711     DOI: 10.1007/s12194-012-0184-z

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  24 in total

1.  Measurement of the presampled two-dimensional modulation transfer function of digital imaging systems.

Authors:  Kenneth A Fetterly; Nicholas J Hangiandreou; Beth A Schueler; E Russell Ritenour
Journal:  Med Phys       Date:  2002-05       Impact factor: 4.071

2.  Image quality in two phosphor-based flat panel digital radiographic detectors.

Authors:  Ehsan Samei
Journal:  Med Phys       Date:  2003-07       Impact factor: 4.071

3.  On site evaluation of three flat panel detectors for digital radiography.

Authors:  Giovanni Borasi; Andrea Nitrosi; Paolo Ferrari; Davide Tassoni
Journal:  Med Phys       Date:  2003-07       Impact factor: 4.071

4.  Determination of the detective quantum efficiency of a digital x-ray detector: comparison of three evaluations using a common image data set.

Authors:  Ulrich Neitzel; Susanne Günther-Kohfahl; Giovanni Borasi; Ehsan Samei
Journal:  Med Phys       Date:  2004-08       Impact factor: 4.071

5.  Guidelines for management of small pulmonary nodules detected on CT scans: a statement from the Fleischner Society.

Authors:  Heber MacMahon; John H M Austin; Gordon Gamsu; Christian J Herold; James R Jett; David P Naidich; Edward F Patz; Stephen J Swensen
Journal:  Radiology       Date:  2005-11       Impact factor: 11.105

6.  Comparison of imaging properties of a computed radiography system and screen-film systems.

Authors:  S Sanada; K Doi; X W Xu; F F Yin; M L Giger; H MacMahon
Journal:  Med Phys       Date:  1991 May-Jun       Impact factor: 4.071

7.  A method for measuring the presampled MTF of digital radiographic systems using an edge test device.

Authors:  E Samei; M J Flynn; D A Reimann
Journal:  Med Phys       Date:  1998-01       Impact factor: 4.071

8.  Computed radiography utilizing laser-stimulated luminescence: detectability of simulated low-contrast radiographic objects.

Authors:  Y Higashida; N Moribe; Y Hirata; K Morita; S Doudanuki; Y Sonoda; N Katsuda; Y Hiai; W Misumi; M Matsumoto
Journal:  Comput Med Imaging Graph       Date:  1988 May-Jun       Impact factor: 4.790

9.  High-speed, single-screen/single-emulsion film systems: basic imaging properties and preliminary clinical applications.

Authors:  Y Higashida; P H Frank; K Doi
Journal:  Radiology       Date:  1983-11       Impact factor: 11.105

10.  Computed radiography utilizing scanning laser stimulated luminescence.

Authors:  M Sonoda; M Takano; J Miyahara; H Kato
Journal:  Radiology       Date:  1983-09       Impact factor: 11.105

View more
  4 in total

1.  Comparison of CsI:Tl and Gd2 O2 S:Tb indirect flat panel detector x-ray imaging performance in front- and back-irradiation geometries.

Authors:  Adrian Howansky; Anastasiia Mishchenko; A R Lubinsky; Wei Zhao
Journal:  Med Phys       Date:  2019-09-23       Impact factor: 4.071

2.  Dose reduction in general radiography for adult patients by use of a dual-side-reading photostimulable phosphor plate in a computed radiography system.

Authors:  Norisato Tsuda; Nobukazu Tanaka; Tsutomu Akasaka; Hidetake Yabuuchi; Junji Morishita
Journal:  Radiol Phys Technol       Date:  2014-05-21

3.  Detectability of simulated interstitial pneumonia on chest radiographs: comparison between irradiation side sampling indirect flat-panel detector and computed radiography.

Authors:  Y Yano; H Yabuuchi; A Kairada; N Tanaka; J Morishita; T Akasaka; Y Matsuo; T Kamitani; Y Yamasaki; M Nagao; M Sasaki
Journal:  Br J Radiol       Date:  2014-05-29       Impact factor: 3.039

4.  Effect of differences in pixel size on image characteristics of digital intraoral radiographic systems: a physical and visual evaluation.

Authors:  Taku Kuramoto; Shinya Takarabe; Kazutoshi Okamura; Kenshi Shiotsuki; Yusuke Shibayama; Hiroki Tsuru; Hiroshi Akamine; Masato Tatsumi; Toyoyuki Kato; Junji Morishita; Kazunori Yoshiura
Journal:  Dentomaxillofac Radiol       Date:  2020-05-07       Impact factor: 2.419

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.