Literature DB >> 10204934

The prediction of failure of the stem in THR by measurement of early migration using EBRA-FCA. Einzel-Bild-Roentgen-Analyse-femoral component analysis.

M Krismer1, R Biedermann, B Stöckl, M Fischer, R Bauer, C Haid.   

Abstract

We report the ten-year results for three designs of stem in 240 total hip replacements, for which subsidence had been measured on plain radiographs at regular intervals. Accurate migration patterns could be determined by the method of Einzel-Bild-Roentgen-Analyse-femoral component analysis (EBRA-FCA) for 158 hips (66%). Of these, 108 stems (68%) remained stable throughout, and five (3%) started to migrate after a median of 54 months. Initial migration of at least 1 mm was seen in 45 stems (29%) during the first two years, but these then became stable. We revised 17 stems for aseptic loosening, and 12 for other reasons. Revision for aseptic loosening could be predicted by EBRA-FCA with a sensitivity of 69%, a specificity of 80%, and an accuracy of 79% by the use of a threshold of subsidence of 1.5 mm during the first two years. Similar observations over a five-year period allowed the long-term outcome to be predicted with an accuracy of 91%. We discuss the importance of four different patterns of subsidence and confirm that the early measurement of migration by a reasonably accurate method can help to predict long-term outcome. Such methods should be used to evaluate new and modified designs of prosthesis.

Entities:  

Mesh:

Year:  1999        PMID: 10204934     DOI: 10.1302/0301-620x.81b2.8840

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  52 in total

1.  [Implant position of total hip arthroplasty shafts. Establishment of a new method for comparison between planned and achieved shaft positions].

Authors:  A Fottner; A Steinbrück; E Volkmer; F Haasters; F Mazoochian; V Jansson
Journal:  Orthopade       Date:  2012-07       Impact factor: 1.087

2.  Analysis of migration of the Nanos® short-stem hip implant within two years after surgery.

Authors:  Stefan Budde; Frank Seehaus; Michael Schwarze; Christof Hurschler; Thilo Floerkemeier; Henning Windhagen; Yvonne Noll; Max Ettinger; Fritz Thorey
Journal:  Int Orthop       Date:  2015-09-25       Impact factor: 3.075

3.  Differences in subsidence rate between alternative designs of a commonly used uncemented femoral stem.

Authors:  Munnan Al-Najjim; Usman Khattak; Juluis Sim; Iain Chambers
Journal:  J Orthop       Date:  2016-07-05

4.  Modes of failure of a threaded acetabular cup : a radiographic study with EBRA of 42 revised cups.

Authors:  Thomas Ilchmann; Severin Neher; Franz Maurer; Kuno Weise
Journal:  Int Orthop       Date:  2006-06-08       Impact factor: 3.075

5.  [The cemented MS-30 stem. A multi-surgeon series of 333 consecutive cases].

Authors:  M Clauss; T Reitzel; M Pritsch; U J Schlegel; R G Bitsch; V Ewerbeck; H Mau; S J Breusch
Journal:  Orthopade       Date:  2006-07       Impact factor: 1.087

6.  The influence of surface topography on wear debris generation at the cement/bone interface under cyclic loading.

Authors:  Kirk A Stoffel; Dongliang T Yang; Dwayne Arola
Journal:  J Mater Sci Mater Med       Date:  2007-10-13       Impact factor: 3.896

7.  Migration of the Duraloc cup after 5 years.

Authors:  Christoph Stihsen; Christof Pabinger; Roman Radl; Peter Rehak; Reinhard Windhager
Journal:  Int Orthop       Date:  2007-07-03       Impact factor: 3.075

8.  Early migration characteristics of a hydroxyapatite-coated femoral stem: an RSA study.

Authors:  David Campbell; Graham Mercer; Kjell G Nilsson; Vanessa Wells; John R Field; Stuart A Callary
Journal:  Int Orthop       Date:  2009-12-13       Impact factor: 3.075

9.  Randomised clinical trial assessing migration of uncemented primary total hip replacement stems, with and without autologous impaction bone grafting.

Authors:  Michael Rutherford; Riaz J K Khan; Daniel P Fick; Samantha Haebich; Oscar Nivbrant; Thomas Kozak
Journal:  Int Orthop       Date:  2019-01-31       Impact factor: 3.075

10.  Pose estimation of artificial hip joint using a single radiographic projection.

Authors:  H Inaoka; A Ishidal; Y Fukuoka; K Suzuki; M Matsubara
Journal:  Med Biol Eng Comput       Date:  2003-01       Impact factor: 2.602

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.