Literature DB >> 20012862

Early migration characteristics of a hydroxyapatite-coated femoral stem: an RSA study.

David Campbell1, Graham Mercer, Kjell G Nilsson, Vanessa Wells, John R Field, Stuart A Callary.   

Abstract

Measurement of early stem subsidence can be used to predict the likelihood of long-term femoral component loosening and clinical failure. Data that examines the early migration pattern of clinically proven stems will provide clinicians with useful baseline data with which to compare new stem designs. This study was performed to evaluate the early migration pattern of a hydroxyapatite-coated press-fit femoral component that has been in use for over ten years. We enrolled 30 patients who underwent THA for osteoarthritis. The median age was 70 years (range, 55-80 years). Patients were clinically assessed using the Harris hip score. Radiostereometric analysis was used to evaluate stem migration at three to four days, six months, one year and two years. We observed a mean subsidence of 0.73 mm at six months, 0.62 mm at one year and 0.58 mm at two years and a mean retroversion of 1.82° at six months, 1.90° at one year and 1.59° at two years. This data suggests that subsidence is confined to the first six months after which there was no further subsidence. The results from this study can be compared with those from novel cementless stem designs to help predict the long-term outcome one may expect from new cementless stem designs.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 20012862      PMCID: PMC3066322          DOI: 10.1007/s00264-009-0913-z

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  23 in total

1.  Accuracy and precision of radiostereometric analysis in the measurement of THR femoral component translations: human and canine in vitro models.

Authors:  I Onsten; A Berzins; S Shott; D R Sumner
Journal:  J Orthop Res       Date:  2001-11       Impact factor: 3.494

2.  The cone hip stem: a prospective study of 13 patients followed for 5 years with RSA.

Authors:  Håkan Ström; Hans Mallmin; Jan Milbrink; Marianne Petrén-Mallmin; Bo Nivbrant; Kurt Kolstad
Journal:  Acta Orthop Scand       Date:  2003-10

3.  The prediction of failure of the stem in THR by measurement of early migration using EBRA-FCA. Einzel-Bild-Roentgen-Analyse-femoral component analysis.

Authors:  M Krismer; R Biedermann; B Stöckl; M Fischer; R Bauer; C Haid
Journal:  J Bone Joint Surg Br       Date:  1999-03

4.  Aseptic stem loosening in primary THA: migration analysis of cemented and cementless fixation.

Authors:  Artur Kroell; Paul Beaulé; Martin Krismer; Hannes Behensky; Bernd Stoeckl; Rainer Biedermann
Journal:  Int Orthop       Date:  2008-12-06       Impact factor: 3.075

5.  Does early micromotion of femoral stem prostheses matter? 4-7-year stereoradiographic follow-up of 84 cemented prostheses.

Authors:  J Kärrholm; B Borssén; G Löwenhielm; F Snorrason
Journal:  J Bone Joint Surg Br       Date:  1994-11

6.  Radiostereometry of hip prostheses. Review of methodology and clinical results.

Authors:  J Kärrholm; P Herberts; P Hultmark; H Malchau; B Nivbrant; J Thanner
Journal:  Clin Orthop Relat Res       Date:  1997-11       Impact factor: 4.176

7.  Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation.

Authors:  W H Harris
Journal:  J Bone Joint Surg Am       Date:  1969-06       Impact factor: 5.284

8.  Primary total hip arthroplasty with an uncemented femoral component: a long-term study of the Taperloc stem.

Authors:  Javad Parvizi; Kjell S Keisu; William J Hozack; Peter F Sharkey; Richard H Rothman
Journal:  J Arthroplasty       Date:  2004-02       Impact factor: 4.757

9.  Movement pattern of the Exeter femoral stem; a radiostereometric analysis of 22 primary hip arthroplasties followed for 5 years..

Authors:  Anna Stefánsdóttir; Herbert Franzén; Ragnar Johnsson; Ewald Ornstein; Martin Sundberg
Journal:  Acta Orthop Scand       Date:  2004-08

10.  Accuracy of migration analysis in hip arthroplasty. Digitized and conventional radiography, compared to radiostereometry in 51 patients.

Authors:  H Malchau; J Kärrholm; Y X Wang; P Herberts
Journal:  Acta Orthop Scand       Date:  1995-10
View more
  31 in total

1.  Early migration of the cemented tibial component of unicompartmental knee arthroplasty: a radiostereometry study.

Authors:  Andrea Ensini; Paolo Barbadoro; Alberto Leardini; Fabio Catani; Sandro Giannini
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-06-04       Impact factor: 4.342

2.  Analysis of migration of the Nanos® short-stem hip implant within two years after surgery.

Authors:  Stefan Budde; Frank Seehaus; Michael Schwarze; Christof Hurschler; Thilo Floerkemeier; Henning Windhagen; Yvonne Noll; Max Ettinger; Fritz Thorey
Journal:  Int Orthop       Date:  2015-09-25       Impact factor: 3.075

3.  Differences in subsidence rate between alternative designs of a commonly used uncemented femoral stem.

Authors:  Munnan Al-Najjim; Usman Khattak; Juluis Sim; Iain Chambers
Journal:  J Orthop       Date:  2016-07-05

4.  Is there any difference between tapered titanium stems with similar geometry and hydroxyapatite coating?

Authors:  G Cinotti; G Mazzotta; F Romana Ripani; G La Torre; G Giannicola
Journal:  Musculoskelet Surg       Date:  2019-01-08

5.  Prospective randomised clinical trial assessing subsidence and rotation, using radiostereometric analysis, of two modular cementless femoral stems (Global K2 and Apex).

Authors:  Mark Edmondson; Jay Ebert; Oscar Nivbrant; David Wood
Journal:  J Orthop       Date:  2014-04-22

6.  Twenty-year results of the cementless Corail stem.

Authors:  Jean-Pierre Vidalain
Journal:  Int Orthop       Date:  2010-09-03       Impact factor: 3.075

7.  Increased risk of periprosthetic femur fractures associated with a unique cementless stem design.

Authors:  Chad D Watts; Matthew P Abdel; David G Lewallen; Daniel J Berry; Arlen D Hanssen
Journal:  Clin Orthop Relat Res       Date:  2014-12-12       Impact factor: 4.176

8.  Randomised clinical trial assessing migration of uncemented primary total hip replacement stems, with and without autologous impaction bone grafting.

Authors:  Michael Rutherford; Riaz J K Khan; Daniel P Fick; Samantha Haebich; Oscar Nivbrant; Thomas Kozak
Journal:  Int Orthop       Date:  2019-01-31       Impact factor: 3.075

9.  Radiographic Subsidence in Asymptomatic Patients After THR Using the Furlong Active HAP Stem.

Authors:  José Cordero-Ampuero; Pablo Peñalver; Rodrigo Antón; María Galán; Enrique Cordero
Journal:  HSS J       Date:  2013-06-21

10.  Reverse hybrid and cemented hip replacement compared using radiostereometry and dual-energy X-ray absorptiometry: 43 hips followed for 2 years in a prospective trial.

Authors:  Einar Lindalen; Jon Dahl; Lars Nordsletten; Finnur Snorrason; Øystein Høvik; Stephan Röhrl
Journal:  Acta Orthop       Date:  2012-11-01       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.