Literature DB >> 9922740

Assessment of implant stability as a prognostic determinant.

N Meredith1.   

Abstract

PURPOSE: This paper aims to establish the parameters necessary to monitor successful implant placement and osseointegration. RESULTS AND DISCUSSION: Implant stability is considered to play a major role in the success of osseointegration. Primary implant stability at placement is a mechanical phenomenon that is related to the local bone quality and quantity, the type of implant and placement technique used. Secondary implant stability is the increase in stability attributable to bone formation and remodeling at the implant/tissue interface and in the surrounding bone. Techniques for measuring implant stability and osseointegration, including the clinical measurement of cutting resistance during implant placement and removal torque following osseointegration, are discussed. Nondestructive test methods, including impact-based techniques such as the Periotest and the Dental Fine Tester, are also discussed. An alternative method, resonance frequency analysis, is described in detail.
CONCLUSION: It is clear that stability both at placement and during function is an important criterion for the success of dental implants. Quantitative methods, including resonance frequency analysis, can yield valuable information.

Mesh:

Substances:

Year:  1998        PMID: 9922740

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  111 in total

1.  The effect of implant shape and bone preparation on primary stability.

Authors:  Sang-Hyun Moon; Heung-Sik Um; Jae-Kwan Lee; Beom-Seok Chang; Min-Ku Lee
Journal:  J Periodontal Implant Sci       Date:  2010-10-31       Impact factor: 2.614

2.  Clinical study on the primary stability of two dental implant systems with resonance frequency analysis.

Authors:  Annette Rabel; Steffen Gerhard Köhler; Andrea Maria Schmidt-Westhausen
Journal:  Clin Oral Investig       Date:  2007-03-31       Impact factor: 3.573

3.  Biomechanical effects of the implant material and implant-abutment interface in immediately loaded small-diameter implants.

Authors:  Aaron Yu-Jen Wu; Heng-Li Huang; Jui-Ting Hsu; Winston Chee
Journal:  Clin Oral Investig       Date:  2013-09-03       Impact factor: 3.573

4.  Assessment of Osstell™ and Periotest® systems in measuring dental implant stability (in vitro study).

Authors:  Samer Al-Jetaily; Abdullah Alfarraj Al-Dosari
Journal:  Saudi Dent J       Date:  2010-11-13

5.  Stability of dental implants after irradiation with an 830-nm low-level laser: a double-blind randomized clinical study.

Authors:  Joelle Marie García-Morales; Pedro Tortamano-Neto; Francisco Fernando Todescan; José Carlos Silva de Andrade; Juliana Marotti; Denise Maria Zezell
Journal:  Lasers Med Sci       Date:  2011-07-06       Impact factor: 3.161

6.  Evaluation of the in vitro cell-material interactions and in vivo osteo-integration of a spinal acrylic bone cement.

Authors:  Sophie Verrier; Lisa Hughes; Antoine Alves; Marianna Peroglio; Mauro Alini; Andreas Boger
Journal:  Eur Spine J       Date:  2011-08-03       Impact factor: 3.134

Review 7.  Implants in bone: part II. Research on implant osseointegration: material testing, mechanical testing, imaging and histoanalytical methods.

Authors:  Cornelius von Wilmowsky; Tobias Moest; Emeka Nkenke; Florian Stelzle; Karl Andreas Schlegel
Journal:  Oral Maxillofac Surg       Date:  2013-02-21

8.  Comparative evaluation of bone in mandibular implant retained overdentures using delayed and immediate loading protocol: an in-vivo study.

Authors:  Manesh Lahori; A S Kaul; Sidhartha Chandra; Rahul Nagrath; Himanshu Gupta
Journal:  J Indian Prosthodont Soc       Date:  2012-12-27

9.  Effects of low-intensity pulsed ultrasound on dental implant osseointegration: a preliminary report.

Authors:  Yakup Ustun; Ozgur Erdogan; Mehmet Kurkcu; Tolga Akova; Ibrahim Damlar
Journal:  Eur J Dent       Date:  2008-10

10.  Biomechanical evaluation of dental implants with different surfaces: Removal torque and resonance frequency analysis in rabbits.

Authors:  Jung-Woo Koh; Jae-Ho Yang; Jung-Suk Han; Jai-Bong Lee; Sung-Hun Kim
Journal:  J Adv Prosthodont       Date:  2009-07-31       Impact factor: 1.904

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.