Literature DB >> 9917605

Hydroxyapatite in total hip arthroplasty. Clinical results and critical issues.

W N Capello1, J A D'Antonio, M T Manley, J R Feinberg.   

Abstract

Surgeons who perform arthroplasties have posed some critical questions about hydroxyapatite. Does hydroxyapatite coating enhance bone ingrowth or ongrowth? Will hydroxyapatite lead to increased polyethylene wear or an increased incidence of osteolysis? Will the hydroxyapatite coating disappear, and if so, what will be left to maintain implant fixation? A multicenter study of 316 hips (282 patients) with a proximally hydroxyapatite coated stem and either a hydroxyapatite or porous coated cup were followed up 8.1 years (range, 5.6-9.9 years). The average patient age was 50 years (range, 16-81 years), and 61% of the patients were male. One (0.3%) stem, three (2.7%) porous coated cups, and 25 (11.9%) hydroxyapatite coated cups were revised for aseptic loosening. Disappointing results on the acetabular side indicate that substrate design is critical. There were no cases of intramedullary femoral osteolysis, and the incidence of acetabular and proximal femoral osteolysis- and polyethylene wear was no greater than that seen with other cementless or cemented components. Based on these clinical results and a critical review of the literature, it is concluded that hydroxyapatite coated hip components do enhance ingrowth or ongrowth with no increased incidence of osteolysis for as many as 10 years. Concern about the disappearance of the hydroxyapatite coating with time seems moot in light of the above clinical findings.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9917605

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  10 in total

1.  Comparison of wear and osteolysis in hip replacement using two different coatings of the femoral stem.

Authors:  Joaquin Sanchez-Sotelo; David G Lewallen; William Scott Harmsen; Jeffrey Harrington; Miguel E Cabanela
Journal:  Int Orthop       Date:  2004-04-29       Impact factor: 3.075

2.  Ten-year follow-up of an anatomical hydroxyapatite-coated total hip prosthesis.

Authors:  V Canales Cortés; J J Panisello Sebastiá; A Herrera Rodríguez; A Peguero Bona; A Martínez Martín; L Herrero Barcos; L García-Dihinx
Journal:  Int Orthop       Date:  2006-02-28       Impact factor: 3.075

3.  Long-term follow-up (11 years plus) results of JRI (Furlong) total hip arthroplasty in young patients: cause for concern regarding acetabular cup?

Authors:  D K Sharma; Stuart Brooks
Journal:  Int Orthop       Date:  2006-06-08       Impact factor: 3.075

4.  Quantitative CT-assisted osteodensitometry of femoral adaptive bone remodelling after uncemented total hip arthroplasty.

Authors:  Rocco P Pitto; Aknaksha Bhargava; Salil Pandit; Cameron Walker; Jacob T Munro
Journal:  Int Orthop       Date:  2007-06-20       Impact factor: 3.075

5.  Stable fixation of short-stem femoral implants in patients 70 years and older.

Authors:  Ronak M Patel; Matthew C Smith; Chase C Woodward; S David Stulberg
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

6.  The Results of Long-term Follow-up of Total Hip Arthroplasty Using Hydroxyapatite-coated Cups.

Authors:  Chang-Dong Han; Keun-Young Shin; Hyun-Hee Lee; Kwan-Kyu Park; Ick-Hwan Yang; Woo-Suk Lee
Journal:  Hip Pelvis       Date:  2015-12-30

7.  Clinical and radiological results of hydroxyapatite-coated acetabular cups.

Authors:  J Blacha; J Gagała
Journal:  Int Orthop       Date:  2004-08-14       Impact factor: 3.075

8.  Thermal analysis studies of poly(etheretherketone)/hydroxyapatite biocomposite mixtures.

Authors:  B J Meenan; C McClorey; M Akay
Journal:  J Mater Sci Mater Med       Date:  2000-08       Impact factor: 3.896

9.  Alumina-on-alumina in THA: a multicenter prospective study.

Authors:  Eduardo Garcia-Cimbrelo; Eduardo Garcia-Rey; Antonio Murcia-Mazón; Agustín Blanco-Pozo; Eduardo Martí
Journal:  Clin Orthop Relat Res       Date:  2008-01-10       Impact factor: 4.176

10.  Failure of dual radius hydroxyapatite-coated acetabular cups.

Authors:  Fabio D'Angelo; Mauro Molina; Giacomo Riva; Giovanni Zatti; Paolo Cherubino
Journal:  J Orthop Surg Res       Date:  2008-08-07       Impact factor: 2.359

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.