Literature DB >> 15316676

Clinical and radiological results of hydroxyapatite-coated acetabular cups.

J Blacha1, J Gagała.   

Abstract

We prospectively studied a consecutive series of 60 primary total hip arthroplasties in 52 patients. All patients had a hydroxyapatite-coated hemispherical acetabular cup (OCTOFIT). Mean patient age was 52.5 (34-73) years. In 38 hips, a 28-mm and in 22 hips a 32-mm diameter cobalt-chrome femoral head was used. We could follow 53 hips for a mean of 81 (28-125) months. Four cups were revised because of osteolysis, and in another six cups, slight osteolysis without migration was seen. The average annual linear wear rate was 0.05 mm (+/-0.05) for 28-mm heads and 0.16 mm (+/-0.09) for 32-mm heads (p<0.0001). Survivorship analysis predicted a survival rate of 86+/-6.7% at 10 years.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15316676      PMCID: PMC3456893          DOI: 10.1007/s00264-004-0563-0

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  25 in total

1.  Cementless acetabular replacement in the young. A 5- to 10-year prospective study.

Authors:  A B Dunkley; J D Eldridge; M B Lee; E J Smith; I D Learmonth
Journal:  Clin Orthop Relat Res       Date:  2000-07       Impact factor: 4.176

2.  Pattern of osteolysis around two different cementless metal-backed cups: retrospective, radiographic analysis at minimum 10-year follow-up.

Authors:  A M Claus; C J Sychterz; R H Hopper; C A Engh
Journal:  J Arthroplasty       Date:  2001-12       Impact factor: 4.757

3.  Medium-term results of the ABG total hip arthroplasty in young patients.

Authors:  Konstantinos A Giannikas; Robert Din; Sahzad Sadiq; Timothy H Dunningham
Journal:  J Arthroplasty       Date:  2002-02       Impact factor: 4.757

4.  Bone ingrowth on a smooth-surfaced hydroxyapatite-coated acetabular cup.

Authors:  Y Y Chung; H D Kim; K S Kim
Journal:  Int Orthop       Date:  2002-08-01       Impact factor: 3.075

5.  Osteolysis: a disease of access to fixation interfaces.

Authors:  Michael T Manley; James A D'Antonio; William N Capello; Avram A Edidin
Journal:  Clin Orthop Relat Res       Date:  2002-12       Impact factor: 4.176

6.  Hydroxyapatite coated hip prosthesis followed up for 5 years.

Authors:  C J Oosterbos; A I Rahmy; A J Tonino
Journal:  Int Orthop       Date:  2001       Impact factor: 3.075

7.  The hydroxyapatite-ABG hip system: 5- to 7-year results from an international multicentre study. The International ABG Study Group.

Authors:  A J Tonino; A I Rahmy
Journal:  J Arthroplasty       Date:  2000-04       Impact factor: 4.757

8.  Polyethylene wear, osteolysis and acetabular loosening with an HA-coated hip prosthesis. A follow-up of 94 consecutive arthroplasties.

Authors:  M Røkkum; M Brandt; K Bye; K R Hetland; S Waage; A Reigstad
Journal:  J Bone Joint Surg Br       Date:  1999-07

9.  Primary total hip arthroplasty with a second-generation cementless total hip prosthesis in patients younger than fifty years of age.

Authors:  Young-Hoo Kim; S-H Oh; J-S Kim
Journal:  J Bone Joint Surg Am       Date:  2003-01       Impact factor: 5.284

10.  High osteolysis and revision rate with the hydroxyapatite-coated ABG hip prostheses: 65 hips in 56 young patients followed for 5-9 years.

Authors:  Jan Blacha
Journal:  Acta Orthop Scand       Date:  2004-06
View more
  1 in total

1.  Excellent results with cementless total hip arthroplasty and alumina-on-alumina pairing: minimum ten-year follow-up.

Authors:  Alexander M Kress; Rainer Schmidt; Ulrich Holzwarth; Raimund Forst; Lutz A Mueller
Journal:  Int Orthop       Date:  2010-11-16       Impact factor: 3.075

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.