The Results of Long-term Follow-up of Total Hip Arthroplasty Using Hydroxyapatite-coated Cups.

Chang-Dong Han1, Keun-Young Shin1, Hyun-Hee Lee1, Kwan-Kyu Park1, Ick-Hwan Yang1, Woo-Suk Lee1.   

Abstract

PURPOSE: The aim of this study was to report the long-term outcome and the failure mechanism of cementless total hip arthroplasty (THA) using hydroxyapatite (HA)-coated acetabular cup.
MATERIALS AND METHODS: From January 1992 to May 1994, a total of 123 consecutive cementless primary THAs were performed using a HA-coated acetabular cup with metal-on-polyethylene articulation. We retrospectively evaluated 66 hips available for follow-up at a mean 18.3 years (range, 10.4-23.6 years). The survival analysis was performed by the Kaplan-Meier method. We defined end point as any failure that required a reoperation of acetabular component.
RESULTS: Thirty-nine of 66 hips (59.1%) were defined as a failure for progressive acetabular osteolysis or aseptic loosening of the cup. Acetabular osteolysis was observed in 47 hips (71.2%) and 33 hips (50.0%) were revised because of cup loosening. The Kaplan-Meier method showed the survival rate of the acetabular cup to be 46.3% at 15 years and 34.8% at 20 years for any failure that required a reoperation of acetabular component.
CONCLUSION: The long-term survival rate of THA using HA-coated acetabular cup was unsatisfactory, and it was attributed to vulnerable property of HA coating and progressive osteolysis.

Entities:  

Keywords:  Acetabular cup; Hydroxyapatite-coated; Long-term outcome; Total hip arthroplasty

Year:  2015        PMID: 27536628      PMCID: PMC4972791          DOI: 10.5371/hp.2015.27.4.209

Source DB:  PubMed          Journal:  Hip Pelvis        ISSN: 2287-3260


  32 in total

1.  Premature wear and osteolysis in an HA-coated, uncemented total hip arthroplasty.

Authors:  P Duffy; J L Sher; P F Partington
Journal:  J Bone Joint Surg Br       Date:  2004-01

2.  The ABG hydroxyapatite-coated hip prosthesis: one hundred consecutive operations with average 6-year follow-up.

Authors:  A Rogers; R Kulkarni; E M Downes
Journal:  J Arthroplasty       Date:  2003-08       Impact factor: 4.757

3.  HA particles can be released from well-fixed HA-coated stems: histopathology of biopsies from 20 hips 2-8 years after implantation.

Authors:  Magne Røkkum; Astor Reigstad; Carina B Johansson
Journal:  Acta Orthop Scand       Date:  2002-06

4.  Anatomic Porous Replacement hip arthroplasty: first 100 consecutive cases.

Authors:  L D Dorr; M Absatz; T A Gruen; M T Saberi; J F Doerzbacher
Journal:  Semin Arthroplasty       Date:  1990-07

5.  Long-term results of HA coated threaded versus HA coated hemispheric press fit cups: 287 hips followed for 11 to 16 years.

Authors:  Olav Reikerås; Ragnhild B Gunderson
Journal:  Arch Orthop Trauma Surg       Date:  2006-06-24       Impact factor: 3.067

6.  Chemical implant fixation using hydroxyl-apatite coatings. The development of a human total hip prosthesis for chemical fixation to bone using hydroxyl-apatite coatings on titanium substrates.

Authors:  R G Geesink; K de Groot; C P Klein
Journal:  Clin Orthop Relat Res       Date:  1987-12       Impact factor: 4.176

7.  Ectopic ossification following total hip replacement. Incidence and a method of classification.

Authors:  A F Brooker; J W Bowerman; R A Robinson; L H Riley
Journal:  J Bone Joint Surg Am       Date:  1973-12       Impact factor: 5.284

8.  Long-term results of the ABG-1 hydroxyapatite coated total hip arthroplasty: analysis of 111 cases with a minimum follow-up of 10 years.

Authors:  R Bidar; P Kouyoumdjian; E Munini; G Asencio
Journal:  Orthop Traumatol Surg Res       Date:  2009-12       Impact factor: 2.256

9.  High revision rate of hydroxyapatite-coated ABG-I prosthesis.

Authors:  Young-Yool Chung; Sung-Chan Ki; Kwang-Young So; Dae-Hee Kim; Kyung Ho Park; Yeon Soo Lee
Journal:  J Orthop Sci       Date:  2009-10-03       Impact factor: 1.601

10.  Increased risk of revision of acetabular cups coated with hydroxyapatite.

Authors:  Stergios Lazarinis; Johan Kärrholm; Nils P Hailer
Journal:  Acta Orthop       Date:  2010-02       Impact factor: 3.717