The Bürch-Schneider anti-protrusio cage in revision total hip arthroplasty: indications, principles and long-term results.

T J Gill1, J B Sledge, M E Müller.   

Abstract

Patients who had a revision total hip arthroplasty using the Bürch-Schneider anti-protrusio cage (APC) by a single surgeon have been reviewed after a minimum of five years. There were 63 operations in 58 patients with an average age of 63 years (41 to 83) at the time of revision. At an average follow-up of 8.5 years (5 to 18), 15 patients (25.9%) rated their results as excellent, 38 (65.5%) as good, and five (8.6%) as fair. Five further revisions of the acetabular prosthesis were required, three due to aseptic loosening, one for recurrent dislocation and one due to sepsis. Of the remainder, one was definitely loose, two probably loose, and 12 possibly so. Impressive augmentation of bone stock can be achieved with the anti-protrusio cage, while enabling the hip to be centred in its anatomical position.

Entities:  

Mesh:

Year:  1998        PMID: 9853483     DOI: 10.1302/0301-620x.80b6.8658

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  25 in total

1.  A review of the treatment of pelvic discontinuity.

Authors:  M Villanueva; A Rios-Luna; J Pereiro De Lamo; H Fahandez-Saddi; M P G Böstrom
Journal:  HSS J       Date:  2008-07-15

Review 2.  [Acetabular defect reconstruction in revision surgery of the hip. Autologous, homologous or metal?].

Authors:  S Gravius; G Pagenstert; O Weber; N Kraska; H Röhrig; D C Wirtz
Journal:  Orthopade       Date:  2009-08       Impact factor: 1.087

3.  Acetabular Defect Reconstruction with Trabecular Metal Augments: Study with Minimum One-year Follow-up.

Authors:  Chirayu Dwivedi; Sandeep Gokhale; Hyun Gon Khim; Jeon Keon Oh; Won Yong Shon
Journal:  Hip Pelvis       Date:  2017-09-06

4.  [Exchange of acetabular cups with severe bone defects using antiprotrusion cages].

Authors:  Bernd Fink; Alexandra Grossmann; Pavel Sebena
Journal:  Oper Orthop Traumatol       Date:  2010-07       Impact factor: 1.154

5.  [Standardized reconstruction of acetabular bone defects using the cranial socket system].

Authors:  Maximilian Rudert; Boris Michael Holzapfel; Florian Kratzer; Reiner Gradinger
Journal:  Oper Orthop Traumatol       Date:  2010-07       Impact factor: 1.154

6.  Acetabular revision arthroplasty using trabecular titanium implants.

Authors:  Boris Steno; Milan Kokavec; Libor Necas
Journal:  Int Orthop       Date:  2014-09-06       Impact factor: 3.075

7.  Use of porous tantalum components in Paprosky two and three acetabular revision. A minimum five-year follow-up of fifty one hips.

Authors:  Xavier Flecher; Benjamin Appy; Sébastien Parratte; Matthieu Ollivier; Jean-Noel Argenson
Journal:  Int Orthop       Date:  2016-10-21       Impact factor: 3.075

8.  Total hip arthroplasty revision in elderly people with cement and Burch-Schneider anti-protrusio cage.

Authors:  L Gaiani; R Bertelli; Massimo Palmonari; G Vicenzi
Journal:  Chir Organi Mov       Date:  2009-04-29

9.  Acetabular revision with metal mesh, impaction bone grafting, and a cemented cup.

Authors:  Martín A Buttaro; Fernando Comba; Rodolfo Pusso; Francisco Piccaluga
Journal:  Clin Orthop Relat Res       Date:  2008-08-13       Impact factor: 4.176

10.  The Burch-Schneider antiprotrusio cage: medium follow-up results.

Authors:  J Lamo-Espinosa; J Duart Clemente; P Díaz-Rada; J Pons-Villanueva; J R Valentí-Nín
Journal:  Musculoskelet Surg       Date:  2012-12-20
View more