PURPOSE: To present preliminary, in vivo temperature measurements during MRI of a pig implanted with a deep brain stimulation (DBS) system. MATERIALS AND METHODS: DBS system (Medtronic Inc., Minneapolis, MN) was implanted in the brain of an anesthetized pig. 3.0-T MRI was performed with a T/R head coil using the low-SAR GRE EPI and IR-prepped GRE sequences (SAR: 0.42 and 0.39 W/kg, respectively), and the high-SAR 4-echo RF spin echo (SAR: 2.9 W/kg). Fluoroptic thermometry was used to directly measure RF-related heating at the DBS electrodes, and at the implantable pulse generator (IPG). For reference the measurements were repeated in the same pig at 1.5 T and, at both field strengths, in a phantom. RESULTS: At 3.0T, the maximal temperature elevations at DBS electrodes were 0.46 °C and 2.3 °C, for the low- and high-SAR sequences, respectively. No heating was observed on the implanted IPG during any of the measurements. Measurements of in vivo heating differed from those obtained in the phantom. CONCLUSION: The 3.0-T MRI using GRE EPI and IR-prepped GRE sequences resulted in local temperature elevations at DBS electrodes of no more than 0.46 °C. Although no extrapolation should be made to human exams and much further study will be needed, these preliminary data are encouraging for the future use 3.0-T MRI in patients with DBS.
PURPOSE: To present preliminary, in vivo temperature measurements during MRI of a pig implanted with a deep brain stimulation (DBS) system. MATERIALS AND METHODS: DBS system (Medtronic Inc., Minneapolis, MN) was implanted in the brain of an anesthetized pig. 3.0-T MRI was performed with a T/R head coil using the low-SAR GRE EPI and IR-prepped GRE sequences (SAR: 0.42 and 0.39 W/kg, respectively), and the high-SAR 4-echo RF spin echo (SAR: 2.9 W/kg). Fluoroptic thermometry was used to directly measure RF-related heating at the DBS electrodes, and at the implantable pulse generator (IPG). For reference the measurements were repeated in the same pig at 1.5 T and, at both field strengths, in a phantom. RESULTS: At 3.0T, the maximal temperature elevations at DBS electrodes were 0.46 °C and 2.3 °C, for the low- and high-SAR sequences, respectively. No heating was observed on the implanted IPG during any of the measurements. Measurements of in vivo heating differed from those obtained in the phantom. CONCLUSION: The 3.0-T MRI using GRE EPI and IR-prepped GRE sequences resulted in local temperature elevations at DBS electrodes of no more than 0.46 °C. Although no extrapolation should be made to human exams and much further study will be needed, these preliminary data are encouraging for the future use 3.0-T MRI in patients with DBS.
Authors: Ali R Rezai; Daniel Finelli; John A Nyenhuis; Greg Hrdlicka; Jean Tkach; Ashwini Sharan; Paul Rugieri; Paul H Stypulkowski; Frank G Shellock Journal: J Magn Reson Imaging Date: 2002-03 Impact factor: 4.813
Authors: Helen S Mayberg; Andres M Lozano; Valerie Voon; Heather E McNeely; David Seminowicz; Clement Hamani; Jason M Schwalb; Sidney H Kennedy Journal: Neuron Date: 2005-03-03 Impact factor: 17.173
Authors: A R Rezai; A M Lozano; A P Crawley; M L Joy; K D Davis; C L Kwan; J O Dostrovsky; R R Tasker; D J Mikulis Journal: J Neurosurg Date: 1999-03 Impact factor: 5.115
Authors: Joo Pyung Kim; Hoon-Ki Min; Emily J Knight; Penelope S Duffy; Osama A Abulseoud; Michael P Marsh; Katherine Kelsey; Charles D Blaha; Kevin E Bennet; Mark A Frye; Kendall H Lee Journal: Biol Psychiatry Date: 2013-08-30 Impact factor: 13.382
Authors: Emily J Knight; Paola Testini; Hoon-Ki Min; William S Gibson; Krzysztof R Gorny; Christopher P Favazza; Joel P Felmlee; Inyong Kim; Kirk M Welker; Daniel A Clayton; Bryan T Klassen; Su-youne Chang; Kendall H Lee Journal: Mayo Clin Proc Date: 2015-06 Impact factor: 7.616
Authors: Myung-Ho In; Shinho Cho; Yunhong Shu; Hoon-Ki Min; Matt A Bernstein; Oliver Speck; Kendall H Lee; Hang Joon Jo Journal: Neuroimage Date: 2017-06-27 Impact factor: 6.556
Authors: William S Gibson; Shinho Cho; Osama A Abulseoud; Krzysztof R Gorny; Joel P Felmlee; Kirk M Welker; Bryan T Klassen; Hoon-Ki Min; Kendall H Lee Journal: Cereb Cortex Date: 2017-03-01 Impact factor: 5.357
Authors: Christopher P Favazza; Deirdre M King; Heidi A Edmonson; Joel P Felmlee; Phillip J Rossman; Nicholas J Hangiandreou; Robert E Watson; Krzysztof R Gorny Journal: Med Devices (Auckl) Date: 2014-10-29
Authors: William S Gibson; Hang Joon Jo; Paola Testini; Shinho Cho; Joel P Felmlee; Kirk M Welker; Bryan T Klassen; Hoon-Ki Min; Kendall H Lee Journal: Brain Date: 2016-06-21 Impact factor: 13.501