Literature DB >> 22422392

Liver T1ρ MRI measurement in healthy human subjects at 3 T: a preliminary study with a two-dimensional fast-field echo sequence.

M Deng1, F Zhao, J Yuan, A T Ahuja, Y-X J Wang.   

Abstract

OBJECTIVES: The aim of this study was to explore the technical feasibility of T(1)ρ MRI for the liver, and to determine the normal range of liver T(1)ρ in healthy subjects at clinical 3 T.
METHODS: There were 15 healthy volunteers. Three representative axial slices were selected to cut through the upper, middle and lower liver. A rotary echo spin-lock pulse was implemented in a two-dimensional fast-field echo sequence. Spin-lock frequency was 500 Hz, and the spin-lock times of 1, 10, 20, 30, 40 and 50 ms were used for T(1)ρ mapping. The images were acquired slice by slice during breath-holding. Regions of interest (ROIs; n=5) were manually placed on each slice of the liver parenchyma region, excluding artefacts and vessels. The mean value of these ROIs (n=15) was regarded as the liver T(1)ρ value for the subject. Six subjects were scanned once at fasting status; six subjects were scanned once 2 h post meal; three subjects were scanned twice at fasting status; and seven subjects were scanned twice 2 h post meal.
RESULTS: When two readers measured the same 10 data sets, the interreader reproducibility (ICC: intraclass correlation coefficient) was 0.955. With the 10 subjects scanned twice, the ICC for scan-rescan reproducibility was 0.764. There was no significant difference for the liver T(1)ρ value at the fasting status (43.08±1.41 ms) and post-meal status (42.97±2.38 ms, p=0.867). Pooling together all the 32 scans in this study, the normal liver T(1)ρ value ranged from 38.6 to 48.3 ms (mean 43.0 ms, median 42.6 ms).
CONCLUSION: It is feasible to obtain consistent liver T(1)ρ measurement for human subjects at 3 T.

Entities:  

Mesh:

Year:  2012        PMID: 22422392      PMCID: PMC3487072          DOI: 10.1259/bjr/98745548

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  29 in total

Review 1.  Medical imaging in pharmaceutical clinical trials: what radiologists should know.

Authors:  Y-X J Wang
Journal:  Clin Radiol       Date:  2005-10       Impact factor: 2.350

2.  SAR and B1 field distributions in a heterogeneous human head model within a birdcage coil. Specific energy absorption rate.

Authors:  C M Collins; S Li; M B Smith
Journal:  Magn Reson Med       Date:  1998-12       Impact factor: 4.668

3.  Projecting future complications of chronic hepatitis C in the United States.

Authors:  Gary L Davis; James E Albright; Suzanne F Cook; Daniel M Rosenberg
Journal:  Liver Transpl       Date:  2003-04       Impact factor: 5.799

4.  The role of laparoscopy in the diagnosis of cirrhosis.

Authors:  J Poniachik; D E Bernstein; K R Reddy; L J Jeffers; M E Coelho-Little; F Civantos; E R Schiff
Journal:  Gastrointest Endosc       Date:  1996-06       Impact factor: 9.427

5.  Sampling variability of liver biopsy in nonalcoholic fatty liver disease.

Authors:  Vlad Ratziu; Frédéric Charlotte; Agnès Heurtier; Sophie Gombert; Philippe Giral; Eric Bruckert; André Grimaldi; Frédérique Capron; Thierry Poynard
Journal:  Gastroenterology       Date:  2005-06       Impact factor: 22.682

Review 6.  Nonalcoholic fatty liver disease: a review of current understanding and future impact.

Authors:  Michael Charlton
Journal:  Clin Gastroenterol Hepatol       Date:  2004-12       Impact factor: 11.382

7.  Water magnetic relaxation dispersion in biological systems: the contribution of proton exchange and implications for the noninvasive detection of cartilage degradation.

Authors:  U Duvvuri; A D Goldberg; J K Kranz; L Hoang; R Reddy; F W Wehrli; A J Wand; S W Englander; J S Leigh
Journal:  Proc Natl Acad Sci U S A       Date:  2001-10-16       Impact factor: 11.205

8.  Protein dynamics studied by rotating frame 15N spin relaxation times.

Authors:  T Szyperski; P Luginbühl; G Otting; P Güntert; K Wüthrich
Journal:  J Biomol NMR       Date:  1993-03       Impact factor: 2.835

9.  Outcome of patients hospitalized for complications after outpatient liver biopsy.

Authors:  C H Janes; K D Lindor
Journal:  Ann Intern Med       Date:  1993-01-15       Impact factor: 25.391

Review 10.  Evaluation of liver fibrosis: a concise review.

Authors:  Nezam H Afdhal; David Nunes
Journal:  Am J Gastroenterol       Date:  2004-06       Impact factor: 10.864

View more
  25 in total

1.  Further exploration of MRI techniques for liver T1rho quantification.

Authors:  Feng Zhao; Jing Yuan; Min Deng; Pu-Xuan Lu; Anil T Ahuja; Yi-Xiang J Wang
Journal:  Quant Imaging Med Surg       Date:  2013-12

2.  Towards consistency for magnetic resonance (MR) relaxometry of lumbar intervertebral discs.

Authors:  Yì-Xiáng J Wáng
Journal:  Quant Imaging Med Surg       Date:  2016-08

3.  Accelerated T1rho relaxation quantification in intervertebral disc using limited spin-lock times.

Authors:  Yi-Xiang J Wang; Feng Zhao; Jing Yuan; Greta Sp Mok; Anil T Ahuja; James F Griffith
Journal:  Quant Imaging Med Surg       Date:  2013-02

4.  Evaluation of liver fibrosis with T1ρ MR imaging.

Authors:  Yi-Xiang J Wang; Jing Yuan
Journal:  Quant Imaging Med Surg       Date:  2014-06

Review 5.  Magnetic Resonance imaging analysis of liver fibrosis and inflammation: overwhelming gray zones restrict clinical use.

Authors:  D Marti-Aguado; A Rodríguez-Ortega; A Alberich-Bayarri; L Marti-Bonmati
Journal:  Abdom Radiol (NY)       Date:  2020-08-28

6.  Chemical Exchange Saturation Transfer (CEST) MR Technique for Liver Imaging at 3.0 Tesla: an Evaluation of Different Offset Number and an After-Meal and Over-Night-Fast Comparison.

Authors:  Min Deng; Shu-Zhong Chen; Jing Yuan; Queenie Chan; Jinyuan Zhou; Yì-Xiáng J Wáng
Journal:  Mol Imaging Biol       Date:  2016-04       Impact factor: 3.488

7.  Accelerated whole-brain multi-parameter mapping using blind compressed sensing.

Authors:  Sampada Bhave; Sajan Goud Lingala; Casey P Johnson; Vincent A Magnotta; Mathews Jacob
Journal:  Magn Reson Med       Date:  2015-04-08       Impact factor: 4.668

8.  Black blood T1rho MR imaging may diagnose early stage liver fibrosis: a proof-of-principle study with rat biliary duct ligation model.

Authors:  Chi-Man Koon; Xin Zhang; Weitian Chen; Eagle Siu Hong Chu; Clara Bik San Lau; Yì-Xiáng J Wáng
Journal:  Quant Imaging Med Surg       Date:  2016-08

Review 9.  Putting it all together: established and emerging MRI techniques for detecting and measuring liver fibrosis.

Authors:  Suraj D Serai; Andrew T Trout; Alexander Miethke; Eric Diaz; Stavra A Xanthakos; Jonathan R Dillman
Journal:  Pediatr Radiol       Date:  2018-08-04

10.  Breath-hold black blood quantitative T1rho imaging of liver using single shot fast spin echo acquisition.

Authors:  Weitian Chen; Queenie Chan; Yì-Xiáng J Wáng
Journal:  Quant Imaging Med Surg       Date:  2016-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.