Literature DB >> 7706027

Vertical optic disk diameter: discrepancy between planimetric and SLO measurements.

A F Spencer1, S A Sadiq, P Pawson, S A Vernon.   

Abstract

PURPOSE: To compare measurements of the vertical diameter of the optic disk using the Heidelberg Retinal Tomograph (HRT) and planimetric methods.
METHODS: On the HRT, three measurements of the vertical disk diameter were made on 32 eyes from a composite image using the circle draw facility and were compared with three measurements of the central image of the 32 tomographic cuts. These were repeated by a second observer. Measurements were compared with those obtained from photographs using the three corrections described by Bengtsson and Krakau.
RESULTS: For the HRT, there was minimal intraobserver variation, coefficient of variation (1.515% to 1.882% for the two observers). Interobserver variation was also small (CoV 1.969%). The authors found the closest agreement with the HRT measurements using regression analysis was obtained using correction 3 (r = 0.8258). HRT measurements were significantly smaller (P < 0.0001) by a constant amount of 0.13 mm across the range of optic disk size. There was a significant difference between the HRT measurement of the composite image and the central cut (P = 0.0003 for observer 1).
CONCLUSIONS: HRT measurements are significantly smaller than those from photographs and, therefore, are not interchangeable.

Entities:  

Mesh:

Year:  1995        PMID: 7706027

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  9 in total

1.  The effect of optic disc diameter on vertical cup to disc ratio percentiles in a population based cohort: the Blue Mountains Eye Study.

Authors:  J G Crowston; C R Hopley; P R Healey; A Lee; P Mitchell
Journal:  Br J Ophthalmol       Date:  2004-06       Impact factor: 4.638

2.  [Measurement of the disc area by indirect ophthalmoscopy].

Authors:  M Haustein; E Schmidt; E Spörl; L E Pillunat; A G Böhm
Journal:  Ophthalmologe       Date:  2009-02       Impact factor: 1.059

3.  Prospective study design for the Heidelberg Retina Tomograph: the effect of change in focus setting.

Authors:  S L Hosking; J G Flanagan
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1996-05       Impact factor: 3.117

4.  Optic disc measurement: a comparison of indirect ophthalmoscopic methods.

Authors:  A F Spencer; S A Vernon
Journal:  Br J Ophthalmol       Date:  1995-10       Impact factor: 4.638

5.  Agreement in assessing optic discs with a digital stereoscopic optic disc camera (Discam) and Heidelberg retina tomograph.

Authors:  Velota C T Sung; Anna Bhan; Stephen A Vernon
Journal:  Br J Ophthalmol       Date:  2002-02       Impact factor: 4.638

6.  Reproducibility of volumetric macular measurements in diabetic patients with the Heidelberg Retina Tomograph.

Authors:  H J Zambarakji; S A Vernon; A F Spencer; W M Amoaku
Journal:  Doc Ophthalmol       Date:  1999       Impact factor: 2.379

7.  Reproducibility of volumetric measurements of normal maculae with the Heidelberg retina tomograph.

Authors:  H J Zambarakji; J E Evans; W M Amoaku; S A Vernon
Journal:  Br J Ophthalmol       Date:  1998-08       Impact factor: 4.638

8.  Variability of the normalised rim/disc area quotient estimated by laser scanning tomography. A comparison with conventional planimetry.

Authors:  A S Boros; C P Jonescu-Cuypers; K U Bartz-Schmidt
Journal:  Int Ophthalmol       Date:  2001       Impact factor: 2.031

Review 9.  Optic disk size and glaucoma.

Authors:  Esther M Hoffmann; Linda M Zangwill; Jonathan G Crowston; Robert N Weinreb
Journal:  Surv Ophthalmol       Date:  2007 Jan-Feb       Impact factor: 6.197

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.